Страница 1: ...uy your excess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing R...

Страница 2: ...UAL Fort Collins CO 80525 USA 970 221 4670 technical support aei com 1625 Sharp Point Drive Advanced Energy Industries Inc AMN PS 2A Automatic Matching Network Power Supply Controller 5708577 A April...

Страница 3: ......

Страница 4: ...User Manual AMN PS 2A Automatic Matching Network Power Supply Controller 5708577 A...

Страница 5: ...not be liable in damages of whatever kind as a result of the reliance on or use of the information contained herein PRODUCT USAGE STATEMENT Read this entire manual and all other publications pertaini...

Страница 6: ...PS 2A TRADEMARKS is a registered trademark of Advanced Energy Industries Inc Advanced Energy is a registered trademark of Advanced Energy Industries Inc AE is a registered trademark of Advanced Energy...

Страница 7: ...vi 5708577 A Advanced Energy...

Страница 8: ...hapter 4 Controls Indicators and Interfaces Remote Interface Connector J2 4 1 Remote Interface Connector J2 Electrical Characteristics 4 1 Interface Cabling Requirements 4 1 Remote Interface Connector...

Страница 9: ...ctions 5 3 Electrical Verification 5 4 Operation 5 4 Automatic Mode 5 5 Manual Mode 5 5 Remote Mode 5 5 Chapter 6 Troubleshooting and Global Support Before Calling AE Global Support 6 1 Troubleshootin...

Страница 10: ...ching Network Interface Connector J1 4 4 Phase Error Voltage Input Port J3 4 6 Magnitude Error Voltage Input Port J4 4 6 Phase and Magnitude Gain Adjustments on Rear Panel 4 7 AMN PS 2A Controller Fro...

Страница 11: ...x 5708577 A Advanced Energy...

Страница 12: ...ons per EN 50178 and EN 60721 3 4 Environmental Specifications 3 4 Remote Interface Connector Signal Types 4 1 Remote Interface Connector J2 Pin Descriptions 4 2 Matching Network Interface Connector S...

Страница 13: ...xii 5708577 A Advanced Energy...

Страница 14: ...xt We use the following type conventions Pin and signal names appear in capitalized italics DUTY CYCLE A Labels that are on the unit switches indicators etc generally appear in boldface capital letter...

Страница 15: ...n labels on your unit This box identifies hazards or unsafe practices that could result in personal injury This box identifies hazards or unsafe practices that could result in product or property dama...

Страница 16: ...Table 1 1 Electromagnetic Compatibility EMC Directive or Standard Description 89 336 EEC EC Council directive on the approximation of the laws of the Member States relating to electromagnetic compatib...

Страница 17: ...ce in an overvoltage category II installation only Install and operate this device only in a pollution degree 2 or better environment which means an indoor location such as a computer room office or f...

Страница 18: ...rms to the applicable requirements The switch must be easily accessible and near the device Install this device so that the input power connection is inaccessible to the user Terminate the ac line cor...

Страница 19: ...1 6 5708577 A Advanced Energy...

Страница 20: ...Vdc for an external fan which is mounted onto and provides additional cooling for the matching network This voltage is provided through pins 14 12 Vdc and 15 ground of the matching network connector...

Страница 21: ...iometers These interfaces and connections are discussed in more detail in Chapter 4 THEORY OF OPERATION The diagram and the paragraphs that follow outline the theory of operation for the AMN PS 2A Fig...

Страница 22: ...als are processed from the motor position sensors and they indicate motor position and provide information on the capacitance of the series capacitor If the comparators receive no signals from these s...

Страница 23: ...2 4 5708577 A Advanced Energy...

Страница 24: ...n 19 in rack mount W x 10 00 in D Weight 2 86 kg 6 3 lb Clearance 5 in 12 7 cm clearance from rear of unit for cable connections Mounting Mount to 19 in rack using four 10 screws Connector Cable speci...

Страница 25: ...115 Vac transformer Line current 1A 115 Vac maximum 0 5A 230 Vac Over current protection non user accessible 115 Vac operation two 0 75 A 250 V Slow blow fuses see Figure 3 1 on page 3 2 230 Vac opera...

Страница 26: ...5708577 A 3 3 AMN PS 2A Figure 3 2 Wiring for 230 Vac Transformer ENVIRONMENTAL SPECIFICATIONS Table 3 3 and Table 3 4 describe the environmental specifications of the AMN PS 2A controller...

Страница 27: ...1K4 80 kPa to 106 kPa 800 mbar to 1060 mbar approximately 2000 m above sea level Transportation Class 2K3 25 C to 70 C 13 F to 158 F Class 2K3 95 Note 2 60 g m3 Note 3 Class 2K3 66 kPa to 106 kPa 660...

Страница 28: ...1 describes the signals used in the AMN PS 2A remote interface connector Interface Cabling Requirements The cable used to connect the AMN PS 2A controller s 25 pin remote interface connector to the sy...

Страница 29: ...tions Signal Pin Name Signal Type Description 1 not used n a n a 2 REMOTE ON OFF LOAD Ground input This pin enables remote operation of the load servomotor when grounded 3 REMOTE ON TUNE Digital outpu...

Страница 30: ...low when the positive load limit is exceeded 11 LOAD METER OUTPUT Analog output This pin s 0 to 5 Vdc output is proportional to the front panel load meter 12 SETPOINT INPUT TUNE Analog input In remote...

Страница 31: ...ctor J1 Figure 4 2 shows the matching network interface connector J1 Figure 4 2 Matching Network Interface Connector J1 Table 4 3 Matching Network Interface Connector Signal Types Signal Type Descript...

Страница 32: ...ply voltage This signal controls clockwise and counterclockwise rotation in the tune servomotor 5 TUNE WIPER Analog input This signal references the position of the tune capacitor potentiometer 6 LOAD...

Страница 33: ...uirements for your system Phase Error Voltage Input Port J3 Figure 4 3 shows the phase error voltage input port J3 Figure 4 3 Phase Error Voltage Input Port J3 Magnitude Error Voltage Input Port J4 Fi...

Страница 34: ...tentiometers are accessed from the AMN PS 2A rear panel as shown in Figure 4 5 To decrease the gain turn the potentiometers clockwise To increase the gain turn the potentiometers counterclockwise Figu...

Страница 35: ...LED When lit this LED indicates that the load capacitor motor has reached its minimum limit 3 LOAD LIMIT maximum LED When lit this LED indicates that the load capacitor motor has reached its maximum...

Страница 36: ...operation modes automatic manual or remote 11 Tune switch When the controller is in manual mode this switch adjusts the tune capacitor Putting the switch in the position adjusts the capacitor in the p...

Страница 37: ...4 10 5708577 A Advanced Energy...

Страница 38: ...sical damage If no damage is apparent proceed with the unit connections If you do see signs of shipping damage contact Advanced Energy Industries Inc and the carrier immediately Save the shipping cont...

Страница 39: ...5 2 5708577 A Advanced Energy DIMENSIONAL DRAWING Figure 5 1 Dimensions...

Страница 40: ...connector J1 on the controller to the 15 pin subminiature D controller interface connector on the matching network For a more detailed description of matching network interface connector J1 see Chapt...

Страница 41: ...ON OFF switch to turn the AMN PS 2A controller off OPERATION The AMN PS 2A has three modes of operation automatic manual and remote The operational mode depends on the settings of the AUTO MAN REM sw...

Страница 42: ...troller no longer drives the servomotors To operate the AMN PS 2A controller in automatic mode place both the load and the tune AUTO MAN REM switches in AUTO position Manual Mode In manual mode the AM...

Страница 43: ...5 6 5708577 A Advanced Energy...

Страница 44: ...sure the input power meets specifications Troubleshooting With the Power On 1 Check the unit s input and remote power connections to ensure that proper power is being supplied to the unit 2 Check the...

Страница 45: ...in the system the phase and or magnitude gain may be set too low To adjust turn the phase and or magnitude gain adjust potentiometers counterclockwise to increase the gain level For an illustration o...

Страница 46: ...ure that input power to PS 2A meets specifications No Input power to the PS 2A No Check whether system related circuit breakers have been tripped AMN PS 2A internal fault Contact AE Global Support Yes...

Страница 47: ...usiness day Note For customers outside the US please contact your local AE office AE Voorhees NJ 1007 Laurel Oak Road Voorhees NJ 08043 USA Phone 800 275 6971 or 856 627 6100 Fax 856 627 6159 AE GmbH...

Страница 48: ...To ensure years of dependable service Advanced Energy products are thoroughly tested and designed to be among the most reliable and highest quality systems available worldwide WARRANTY Advanced Energ...

Страница 49: ...at no charge Units that are returned without authorization from AE Global Support and that are found to be functional will not be covered under the warranty see warranty statement below That is you w...

Страница 50: ...description of PS 2A general 2 1 dimensions drawing of 5 2 E electrical specifications 3 1 electrical verification 5 4 environmental specifications 3 3 error voltage input connectors J3 and J4 4 6 con...

Страница 51: ...gory 1 4 P phase error voltage input port J3 4 6 gain adjustor 4 7 physical specifications 3 1 pin descriptions remote interface J2 4 2 pollution degree 1 4 power input specifications 3 1 protection o...

Страница 52: ...th the power on 6 1 procedures 6 3 tune LIMIT LEDs 4 9 meter 4 9 U unpacking the controller 5 1 use conditions of 1 4 user manual symbols used 1 2 type conventions 1 1 V verification electrical 5 4 W...

Страница 53: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...