Operation

Terminate TWTA RF input and output. Connect external Interface as desired. Apply prime power.   

Caution:  The TWTA must never be placed in Operate without proper RF termination. This can lead
to TWT oscillations which can permanently damage the TWT. 

Power TWTA On:

Press   the   manual   WARM   UP  button   to   power   the   TWTA.   The   manual   WARM   UP  button   will
illuminate. Front panel display will show “Warm up” and the remaining warm-up time in the status
area.

At initial power-up, heater voltage will be less than nominal to limit excessive current drawn by a cold
filament. As the filament warms it will draw less current and the filament voltage will increase until
nominal voltage is reached. Negative Bias voltage is applied to the Grid. Body and Collector supplies
are off. The standard warm-up period is 5 minutes.

Standby from Warm-up:

After the warm-up period has elapsed the TWTA is placed in STANDBY by the main microprocessor.
High voltage supplies and Grid voltage remain unchanged from the WARM UP state. The manual
STANDBY button is illuminated and the WARM UP/OFF button is extinguished. The front panel
display will indicate “Standby” on the status area. The TWTA can be now placed in OPERATE. 

Operate:

Press the OPERATE button to place the TWTA in OPERATE state or send the OPERATE command
from   the   remote   computer.   The   OPERATE   button   is   illuminated   and   the   STANDBY   button   is
extinguished. The front panel display will indicate “Operate” on the status bar and the background
color will change to green.

The Main microprocessor engages the Collector voltage soon after the OPERATE command is received
and the Body voltage 500 ms after the Collector voltage stabilizes. Then it waits up to 3 seconds for the
Collector voltage to stabilize before going to OPERATE. Both STANDBY and OPERATE buttons are
illuminated during the High Voltage on sequence. The amplifier goes to RESET if the voltages don’t
reach the nominal values within allowed time. 8 s after the high voltages have reached their nominal
values,   pulses   are   passed   unaltered   to   the   Floating   Deck   where   they   are   subject   to   PRF   (Pulse
Frequency) and PW (Pulse Width) limiting. The TWT beam current will be present within up to 13.5 s
after the TWTA OPERATE command is sent. 

If RF and video pulses (pulsed units) are supplied, the TWTA will produce an amplified RF output.   

Standby from Operate:

When placed in STANDBY by user command, the main processor sequentially interrupts video pulses
to the Floating Deck, disengages the Body and Collector supplies and returns the TWTA to STANDBY.

Page 10 of 14

Содержание AA-1218G-3.5KW-PT

Страница 1: ...User Manual AA 1218G 3 5KW PT R F MICROWAVE AMPLIFIER SYSTEM Advanced Amplifiers 10401 Roselle Street San Diego CA 92121 Telephone 808 404 2832...

Страница 2: ...ose of the Equipment 3 General System Introduction 4 Installation 4 TWTA connections 4 Front Panel Display 6 Operation 9 Remote Operation 12 Explanations of analog values 12 Explanation of Faults and...

Страница 3: ...AC power Do Not operate this equipment without both RF input and RF output being properly terminated Do Not bypass or attempt to modify the operation of the Safety Interlock Switch Without covers in p...

Страница 4: ...onfigurations specified at time of manufacture Installation Locate amplifier in such a manner that adequate cool air is available to the fan inlet on the front of the unit Do not restrict space in the...

Страница 5: ...ses RF input TWT Input for user supplied RF RF output Amplified TWT RF output Remote communications Connection for user specified external communications Primary power User specified 120 or 240VAC 50...

Страница 6: ...rents and voltages stabilize In this state the status bar shows how much time is left to finish the warm up After the warm up time finishes the unit enters STANDBY In STANDBY and OPERATE the status ar...

Страница 7: ...me the unit has been in powered on Total time in operate Total Time the unit has been in OPERATE high voltages on Total time main uptime The main control board is powered whenever the prime power inpu...

Страница 8: ...inL is undefined while PinD shows 100 The values shown correspond to pulses which will modulate the amplifier s output when the amplifier is in OPERATE So the values represent the output of the intern...

Страница 9: ...fier s manufacturer System tab picture 12 shows general information about the amplifier and selected technical data The following information is available Model Series Rated power output Min and max s...

Страница 10: ...w placed in OPERATE Operate Press the OPERATE button to place the TWTA in OPERATE state or send the OPERATE command from the remote computer The OPERATE button is illuminated and the STANDBY button is...

Страница 11: ...he TWTA in RESET if the amplifier is in WARMUP STANDBY or OPERATE Heater Voltage and Current Drive Voltage Collector Voltage and Current Body Voltage and Cathode Current are all directly monitored by...

Страница 12: ...r will enter the FLASHING RESET mode again Gassy TWT If the TWTA has been inactive for several months the TWT may build up gasses This allows the TWT to arc internally and cause repeated TWTA faults T...

Страница 13: ...drive pulses interspersed with the negative bias voltage The amount of reduction is directly proportional to the duty cycle of the pulses applied Bias V Direct measurement of Bias Voltage Not present...

Страница 14: ...and Flags Temperature Fan TWT temperature has exceeded acceptable levels or a cooling fan is outside its current range Causes a fault Interlock The enclosure cover has been removed or loosened Causes...

Отзывы: