Chapter 5 Installing Shelves
Installation and Commissioning Manual
165
F
S
P
3000R
7 R
11
.1 8000
0015930
Issue
B
, ©
2012
ADVA AG Optical Netw
orking
ADVA Conf
idential
Step 5
Remove the protective cover from the terminal block (e.g. Power A)
as follows:
a) Using the screwdriver size 1, completely remove the two fixing
screws from the protective cover to the terminal block
b) Take off the cover and lay it aside with the screws as it will be
required later.
Step 6
Using the Phillips screwdriver size 2, remove the three terminal
screws from the terminal block and lay these screws aside for later
use.
Step 7
Inspect the terminal block for damage. Do not proceed if one or more
terminal screws are damaged!
Step 8
Follow
when connecting one of the following cable types to the
shelf:
•
CBL/DC/300/2AWG16/TB
•
CBL/DC/300/3AWG14/TB
•
PC300/3WIRE/RED/BLACK/14AWG
If you want to connect a CBL/DC/300/3AWG14/FLT/R-/B+ to the
shelf, continue with
P
S
Note
Not all protective covers come with captive screws, therefore be
careful to retain the screws. Fixing screws (shown in
) can
fall off and become lost when the protective cover is mounted or
removed.
P
S
Note
A damaged terminal block must not be replaced in the field! The
damaged power supply unit or the whole 1HU Shelf must be returned
to ADVA Optical Networking for repair.