Total Access 1248 Quad T1 IMA 48-Port DSLAM with Modem Installation and Maintenance Practice
5-82
61179641AL1-5C
NOTE
Auto Upgrade operations will not be initiated if the AUC Refresh
Interval option is set to zero, the AUC Config File option is empty,
the configuration file cannot be retrieved from the AUC TFTP
Server, or the configuration file contains errors.
Table 5-50. Auto Upgrade Configuration (AUC) Status Menu Options
Option
Description
Function
1
AUC Config File
This option is used to enter the AUC Config File name.
The text entry field is limited to 40 characters and must
end with the
*.auc
file extension.
2
AUC Mode
This option is used to specify the auto upgrade mode.
Options include the following:
• Auto - indicates that unit should be automatically
checked and upgraded.
• Manual - indicates that unit should be checked at
the AUC Refresh Interval rate and upgraded only
when instructed via SNMP or the menus.
• Disable - all automatic upgrade operations are
disabled.
3
AUC Refresh Interval
This option specifies how often (in hours) the unit
should check the AUC TFTP Server for changes to the
AUC Config File. Valid entries are 0 - 744. A value of zero
(0) indicates the server should not be checked and dis-
ables any further Auto Upgrade operations.
4
AUC Upgrade Retries
This option specifies the number of software upgrade
attempts that are to be made as a result of a failure.
Valid entries are 0 - 10.
5
AUC TFTP Server
This option specifies the IP address of the AUC TFTP
Server.
6
AUC Base Path
This option specifies a directory prefix where the Auto
Upgrade configuration and flash firmware files will be
located on the customer file server.