Содержание Octal E&M

Страница 1: ...Octal E M Module User Manual Part Number 1200313L1 61200313L1 1A August 2000...

Страница 2: ...901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2000ADTRAN Inc All Rights Reserved Printed in U S A...

Страница 3: ...n which case the user will be required to correct the interference at his own expense Shielded cables must be used with this unit to ensure compliance with Class A FCC limits Canadian Emissions Requir...

Страница 4: ...TRAN AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESSED OR IMPLIED ADTRAN SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES INCLUDING WITHOUT LIM ITATION ALL WARRANTIES OF MERCHANTABILITY AND FITNESS...

Страница 5: ...2 1 Shipping Contents 2 1 Installing the Octal E M Module 2 2 Wiring 2 3 Power Up and Initialization 2 3 Operation Alarms 2 3 Chapter 3 Operation 3 1 Overview 3 1 Terminal Menu Structure 3 2 Modules...

Страница 6: ...6 TO 3 6 Test E Lead Open 3 6 Test E Lead Closed 3 6 Test 3 6 Rx Tx ABCD 3 6 Test 3 6 Test 2W 3 6 Tx ABCD 3 7 1kHz Tone 3 7 Loopback 3 7 Configuration 3 7 Port 3 7 Port Name 3 7 Sig Ifce 3 8 VF Ifce 3...

Страница 7: ...st of Figures Figure 1 1 Octal E M Module 1 2 Figure 2 1 Installing the Octal E M Module 2 2 Figure 3 1 Modules Menu 3 2 Figure 3 2 Menu Tree for Octal E M Module Menu 3 3 Figure 3 3 Octal E M Module...

Страница 8: ...List of Figures viii Octal E M Module User Manual 61200313L1 1...

Страница 9: ...61200313L1 1 Octal E M Module User Manual ix List of Tables Table 2 1 Pinout Connection 2 3 Table 2 2 Trunk Circuit Connections for Various E M Signaling Types 2 3 Table 3 1 Test 2W Information 3 7...

Страница 10: ...List of Tables x Octal E M Module User Manual 61200313L1 1...

Страница 11: ...550 chassis Status information is available via the terminal menus accessible through either a VT 100 terminal connected to the ATLAS 550 control port or via a Telnet session established through the...

Страница 12: ...he Octal E M Module plugs into any available option slot in the rear of the ATLAS 550 chassis Figure 1 1 shows the Octal E M Module Figure 1 1 Octal E M Module The labels over the modular connectors r...

Страница 13: ...ile a claim immediately with the carrier and then contact ADTRAN Technical Support see the last page of this manual for pertinent information If possible keep the original ship ping container for retu...

Страница 14: ...ONLY WITH SAME TYPE AND RATING OF FUSE MON Remove Cover Plate I O 1 OCTAL FXO 2 3 4 5 6 7 8 Instructions for Installing the Octal E M Module Step Action 1 Remove the cover plate from the appropriate...

Страница 15: ...p See the ATLAS 550 User Manual for more information about the power up sequence Operation Alarms The red ALARM LED located with the Module LEDs on the front panel il luminates when an alarm condition...

Страница 16: ...Chapter 2 Installation 2 4 Octal E M Module User Manual 61200313L1 1...

Страница 17: ...yed in the DIAL PLAN menus see Appendix A Dial Plan Interface Configuration on page A 1 Access the terminal menu using either a VT 100 terminal attached to the ATLAS 550 Base Unit s control port or a...

Страница 18: ...as E M 8 under TYPE MODULES MENU The ATLAS 550 system controller automatically detects the presence of the Octal E M Module when it is installed in the system To see the menus for the Octal E M Module...

Страница 19: ...ure a system before actually installing modules by simply specifying the module that you want to install in each slot If you intentionally leave a slot empty mark it as EMPTY to avoid get ting a NOT R...

Страница 20: ...st be marked as ONLINE for it to be considered an available resource This parameter allows an installed module to be marked as OFFLINE which may be useful in system troubleshooting If you choose OFFLI...

Страница 21: ...following sections describe these options Figure 3 3 Octal E M Module Menu Options INFO Provides read only information about module part number serial number assembly revision and firmware revision PA...

Страница 22: ...Transmit Signaling bits have local significance only and repre sent E M signaling between the ATLAS 550 Controller and the voice port The bit pattern is formatted ESF RBS TEST Displays the test name i...

Страница 23: ...ts on a per port basis CONFIGURATION Provides menu options for configuring the module PORT Identifies the port PORT NAME Allows the user to assign a meaningful name to the port Table 3 1 Test 2W Infor...

Страница 24: ...le FACTORY RESTORE and RUN SELFTEST FACTORY RESTORE You can restore the factory default settings for the Octal E M Module by pressing F either while the cursor is over the SLT number this action resto...

Страница 25: ...he IFCE CONFIG option for the DIAL PLAN menu see Figure A 1 sets config uration parameters for the endpoint These parameters vary by the type of port selected The DIAL PLAN menus are only accessible w...

Страница 26: ...rite security 3 Read security 5 Defines whether the end user equipment requires digits to be delivered after going off hook CALLER ID NUMBER Assigns a calling party number to a port when it originates...

Страница 27: ...dialed number Multiple endpoints can have the same SOURCE ID When creating the CALL ACCEPT list specify one or more SOURCE IDS as well as a dialed number or range of dialed numbers to accept EXAMPLE A...

Страница 28: ...Appendix A Dial Plan Interface Configuration A 4 Octal E M Module User Manual 61200313L1 1...

Страница 29: ...e Revision 3 5 Functional Description 1 1 H hardware revision 3 5 I Idle Status 3 6 Ifce Config A 1 Inactive Status 3 5 Info 3 5 initialization 2 3 installing the module 2 1 Interface Configuration A...

Страница 30: ...ID A 3 State 3 4 Status 3 4 3 5 Disabled 3 5 Empty 3 4 Idle 3 6 Inactive 3 5 No Response 3 4 Offline 3 5 Offline No Response 3 5 Online 3 4 Status Status 3 5 Strip MSD A 2 T terminal menu structure 3...

Страница 31: ...repair is needed Technical Support will coordinate with the Customer and Product Service CAPS department to issue an RMA number For information regard ing equipment currently in house or possible fees...