background image

NetVanta E1/FE1 + G.703 Drop Network Interface Module (NIM)

P/N 1200878L1

For more detailed documentation, visit us online at 

www.adtran.com

.

Quick Start Guide

®

Quick Start Guide, 61200878L1-13C, March 2005

ADTRAN Technical S1-256-963-8716

Copyright © 2005 ADTRAN, All Rights Reserved

S

PECIFICATIONS

Operating Modes

E1/FE1 Frame Relay, E1/FE1 PPP

E1/FE1 Interface

Line Rate: 2.048 Mbps ±50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
FE1 Line Rate: Timeslot, channelized (in multiples of 
56/64 kbps)
Receiver Sensitivity: -30 dB
Connector: RJ-48C

G.703 Interface

Line Interface: Per ITU-T G.703
Receiver Sensitivity: -30 dB
Line Rate: 2.048 Mbps, ±50 PPM
Capacity: 1 to 31 timeslots
If timeslot 16 signaling is used on the drop port, a maximum 
of 15 timeslots can be mapped to router (1 to 15 or 17 to 31).
Line Code: AMI or HDB3
Framing: FAS with Optional CRC-4
Connector: RJ-48C

Clock Source

Network, Internal, and Through

Diagnostics

Test Pattern Generation and Detection: QRSS, 511
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and 24 hours)

Standards

FCC Part 15 Class A, EN 55022 Class A, EN 55024, 
EN 61000-3-2, EN 61000-3-3
ACIF S016, ETSI TBR 12/TBR 13
EN60950, AS/NZS 60950, IEC 60950
ITU G.703, ITU-T G.704 (CRC-4), ITU-T G.823,
ITU-T G.797

Physical

Dimensions: 2.75 inch W x 4.25 inch D
Operating Temperature: 0°C to 50°C
Storage Temperature: -40°C to 85°C
Relative Humidity: Up to 95 percent, noncondensing

WAN-E1

G.703

DBU

 

I

NSTALLATION

 I

NSTRUCTIONS

1.

Remove power from the unit.

2.

Slide the Network Interface Module (NIM) into the option slot 
until the NIM is firmly seated against the front of the chassis.

3.

Secure the pins at both edges of the NIM.

4.

Connect the cables to the associated device(s).

5.

Complete the installation of the base unit.

6.

Restore power to the unit.

WAN-E1 N

ETWORK

 (RJ-48C) C

ONNECTION

 P

INOUT

Pin

Name

Description

1

R1 

Receive data from the network

2

T1

Receive data from the network

3

Unused

4

Transmit data toward the network

5

Transmit data toward the network

6-8

Unused

G.703 (RJ-48C) C

ONNECTION

 P

INOUT

Pin

Name

Description

1

Transmit data toward the DTE

2

Transmit data toward the DTE

3

Unused

4

R1

Receive data from the DTE

5

T1 

Receive data from the DTE

6-8

Unused

NetVanta modules should be installed only in 
NetVanta Series products.