NETVANTA E1/FE1 NETWORK INTERFACE MODULE (NIM)
P/N 1200868L1
For more detailed documentation, visit us online at
www.adtran.com
Quick Start Guide
Quick Start Guide, 61200868L1-13B, February 2004
ADTRAN Technical Support (+1-256-963-8716)
© 2004 ADTRAN, All Rights Reserved
S
PECIFICATIONS
E1/FE1 Interface
Line Rate: 2.048 Mbps +/- 50 PPM
Line Code: AMI or HDB3
Framing: FAS with optional CRC-4
Receiver Sensitivity: -30 dB
FE1 Line Rate: Timeslot, channelized (in
multiples of 64 kbps)
Connector: RJ-48C
Clock Source
Network, Internal
Diagnostics
Test pattern generation and detection (QRSS,
511)
Network loopbacks
Alarm generation and detection
Network performance data (15 minutes and
24 hours)
I
NSTALLATION
I
NSTRUCTIONS
1. Remove power from the unit.
2. Slide the Network Interface Module (NIM) into the option
slot until the NIM is firmly seated against the front of the
chassis.
3.
Secure the pins at both edges of the NIM.
4.
Connect the cables to the associated device(s).
5.
Complete the installation of the base unit.
6.
Restore power to the unit.
WAN-E1
DBU
WAN-E1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUT
Pin
Name
Description
1
R1
Receive data from the network
2
T1
Receive data from the network
3
—
Unused
4
R
Transmit data toward the network
5
T
Transmit data toward the network
6-8
—
Unused
DBU (RJ-48C) C
ONNECTION
P
INOUT
Pin
Name
Description
1-2
—
Unused
3
R1
Network-Ring1
4
R Network-Ring
5
T Network-Tip
6
T1
Network-Tip1
7-8
—
Unused
An optional Dial Backup Interface Module (DIM) is
required for dial backup applications.