background image

61287565G1-22B

3

Step 4: Connect Fiber

CAUTION

C

LASER RADIATION
1310 nm to 1600 nm
Do not view directly with optical instruments.
This product contains a Class 1M Laser module that complies
with 21 CFR 1040.10 and 1040.11 and IEC 60825-1 and -2.

Fiber is installed in an SC/APC connecter located behind a 
removable protector panel on the right-rear of the Small Form 
Factor ONT. Refer to the figures below and the following steps to 
install fiber:

1. Remove the Protective Panel and slide it back (in the direc-

tion of the dashed arrow) to expose the SC/APC connector.

2. Refer to the illustration below and pull the Protective Cover 

from the SC/APC Connector.

3. Clean the ends of the Incoming Fiber and the SC/APC 

Connector.

4. Refer to the illustration at the top of the next column and 

connect the Incoming Fiber to the SC/APC Connector.

ETH
Port

Fiber
Port

Protective
Panel

Protective 
Cover

SC/APC
Connector

Incoming 
Fiber

5. Route the fiber cable through the slot in the Protective Panel.
6. Replace the Protective Panel on the Small Form Factor ONT, 

and secure it with the retaining screw.

NOTE

When the SC/APC fiber connection is not in use, replace the
Protective Cover. This will help keep the optical connection clean.

Step 5: Connect Power

Refer to the following illustration and steps when connecting 
power and turning the Small Form Factor ONT On and Off.

1. Plug the supplied 12 V AC/DC Power Converter into the 

PWR

 connection on the rear of the chassis. 

2. Connect the power plug to a standard 120 V AC outlet.

ON/OFF Button

An On/Off button is located on the back of the Small Form Factor 
ONT. 

LED S

TATUS

The LEDs are located beneath the plastic housing and are only 
visible after power has been applied. The following table provides 
the LED status during normal operations.

Label

Status

Indication

PWR

Off
Green

ONT power is Off
ONT power On

GPON

2

Off
Green
Green Flashing 

ONT is not active 
ONT is active 
ONT is activating 

OPTICAL

2

Off

Red

Red Flashing

ONT is receiving optical power 
normally
ONT PON optical module 
power is off
ONT receiving low optical 
power

LAN 

2

Off
Green

Green Flashing Fast

ETH Port not connected
ETH Port connected, but data is 
not being transmitted
ETH Port connected, and data 
is being transmitted 

Power

On/Off

RESET
Button

Отзывы: