background image

1

61291006L2-5B

Section 61291006L2, Issue 2

1. GENERAL

This practice provides installation and maintenance
procedures for the ADTRAN D4 Total Reach Office
Channel Unit Dataport (TROCU DP) Preferred
Option. The unit is illustrated in Figure 1.

Document Revision History

Issue 2 of this document revises the Deployment
Guidelines subsection.

Description

ADTRAN D4 TROCU DP Preferred Option is a
functional replacement for the D4 OCU DP,
delivering data at rates up to 64 kbps on a single
copper pair. Used in combination with the Total
Reach Digital Data Service Remote termination unit
(TRDDS-R), the TROCU DP can accommodate
extended loop lengths eliminating the need for DDS
repeaters. The TROCU DP span powers the remote
TRDDS-R located at the customer premise. The
TRDDS-R converts the two-wire signal to the

Model TROCU DP Preferred Option

Total Reach

®

 All-Rate DDS Dataport

Installation and Maintenance

Section 61291006L2-5

Issue 2, June 1999

CLEI Code #D4D3MPY_ _ _

Trademarks: Any brand names and product names included in this document are
trademarks, registered trademarks, or trade names of their respective holders.

traditional four-wire Alternate Mark Inversion (AMI)
signal for presentation to the customer.

The TROCU DP occupies a single channel position in
the WECO

®

 compatible D4 channel bank or the

AT&T

®

 SLC-96 Mode I and III terminal. It provides

the interface between a DS0 timeslot of the T-carrier
data stream, and the two-wire metallic loop extending
to the customer premises.

The TROCU DP may interoperate over the carrier
system with another TROCU DP, an OCU DP, a DS0
DP, a 1/0 DCS, or the central office switch. The unit
can be located in an end office, hub office,
intermediate office, or remote terminal digital carrier
system (see Figure 2). The two-wire loop is
connected using the tip (pin 24) and ring (pin 51) on
the D4 backplane.

Figure 1.  TROCU DP Preferred Option

T-Carrier

D4 or SLC-96

2-Wire Loop

4-Wire Customer

Interface

DSU/CSU

TRDDS-R

TR

OCU

DP

T/R Pair

Customer Premises

Figure 2.  Total Reach DDS Circuit Diagram

SYNC

NEAR

FAR

REM

QM

NO

LBK

IDLE

Rx

Tx

   SC
    64
    56
 19.2
   9.6
   4.8
   2.4
SW56

TROCU DP

1291006L2

SD4 2-WIRE

LOSS

CRC

CRC

DISC

DSU

(OUT)

(IN)

AP

L

O
G

I

C

SW1

CONTENTS

1. GENERAL ..................................................................... 1
2. OPTIONS ...................................................................... 2
3. INSTALLATION ........................................................... 3
4. TESTING ....................................................................... 3
5. REMOTE PROVISIONING AND

DIAGNOSTICS ............................................................. 4

6. DEPLOYMENT GUIDELINES .................................... 5
7. WARRANTY AND CUSTOMER SERVICE ............... 6

FIGURES

Figure 1.  TROCU DP Preferred Option ............................. 1
Figure 2.  Total Reach DDS Circuit Diagram ..................... 1
Figure 3.  Option Switch ..................................................... 2
Figure 4.  Rate Selection ..................................................... 2
Figure 5.  OCU Loopback at the TROCU DP ..................... 4
Figure 6.  TROCU DP Bidirectional Loopback

Pass-Thru Mode ................................................. 4

Figure 7.  TROCU DP Bidirectional Loopback

Normal Mode ..................................................... 4

TABLES

Table 1.  Preprovisioning ..................................................... 3
Table 2.  Cable Type Loss Data @ 13.3 kHz ....................... 3
Table 3.  LED Indicators ..................................................... 5
Table 4.  TRDDS Insertion Loss Measurements ................. 5

Отзывы: