TROUBLESHOOTING GUIDE

CARD EDGE PINOUT

ADTRAN uses negative ground-referenced span powering voltage (–190 VDC) on the 
HDSL2 loop. If desired, disable H2TU-R span powering to allow locally powered H2TU-R 
applications. 
H2TU-C for Litespan plugs directly into a Litespan channel bank assembly channel unit slot. 
Litespan system software must be version 11.0.0 or higher. The tip and ring connections 
from the H2TU-C to the shelf are made through card edge pins A3 (Narrowband Tip) and A4 

(Narrowband Ring).
H2TU-C for Litespan supports narrowband cabling on the Litespan RT shelf. For more 
information regarding the cabling, refer to Alcatel document OSP 363-405-270.

COMPLIANCE

Condition

Solution

Power up: all 
front panel 
indicators 

off

1. Verify that the channel bank or ONU BPS power LEDs are on.
2. Make sure that unit is fully and correctly inserted into the channel bank or ONU.
3. If step 1 fails, contact Alcatel customer service (800-848-0333). If step 1 passes, 

but step 2 fails, replace the H2TU-C.

STAT

 LED 

Red.

1. Verify that the channel bank or ONU BPS power LEDs are on.
2. Verify that the equipment type for the Litespan H2TU-C slot is AHDSL2. Using 

TL1, equipment type is shown with the command rtrv-eqpt::AID, where AID is 
the access identifier (i.e., cot-1-15).

3. If step 1 fails, contact Alcatel customer service. If step 1 and step 2 pass, replace 

the H2TU-C. If step 1 passes but step 2 fails, delete the equipment record (i.e., 
dlt-eqpt::cot-1-15 with TL1) and reinsert the card, or equip the slot with the 
currently reserved equipment type.

STAT

 LED 

off; 

HLOS

 

LED 

Red

1. Confirm that the HDSL2 loop is not open.
2. Confirm that the HDSL2 loop is not shorted.
3. Verify the loop conforms to CSA guidelines and is not too long. Loop loss at 196 

kHz should be less than 35 dB.

4. Verify that the HDSL2 loop has acceptable noise limits.
5. Verify that tip and ring of each HDSL2 loop belongs to the same twisted pair.
6. If steps 1 through 5 pass, but the 

HLOS

 LED remains red, replace the H2TU-C.

7. If step 6 fails, replace the H2TU-R.

STAT

 LED 

off; 

RLOS

 

LED 

Red.

1. Check that framing line coding are set appropriately for T1 data at the H2TU-R.
2. Check that the 

RLOS

 LED at the H2TU-R is off.

3. If step 1 fails, change the appropriate framing and line coding. If step 1 passes, 

but step 2 fails, a problem may exist at the H2TU-R T1 interface. If the problem 
does not exist at the T1 interface, replace the H2TU-C.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

FRONT PANEL LEDS

INSTALLATION

After unpacking the unit, inspect it for damage. If damage is noted, file a claim 
with the carrier and then contact ADTRAN. Refer to Warranty. 
Follow the steps below to install the H2TU-C for Litespan:

1. If present, remove the Access Module Blank from the appropriate access 

module slot of the chassis.

2. Pull the ejector latch, located on the lower right-hand side of the H2TU-C 

for Litespan front panel, from its closed position.

3. Hold the H2TU-C for Litespan by the front panel while supporting the 

bottom edge of the module with the ejector latch opened to engage the 
chassis edge. Align the module edges to fit in the lower and upper guide 
grooves for the access module slot.

4. Slide the module into the access module slot. Simultaneous thumb pressure 

at the top and at the bottom of the module ensures that the module is firmly 
positioned against the backplane of the chassis. Secure the module in place 

by pushing up and in on the ejector latch.

When installed, the H2TU-C for Litespan runs a series of self-tests. Once the 
self-tests are complete, the status LEDs reflect the true state of the hardware.

Label

Status

Description

DSL

z

z

z

2

Green
Yellow
Red
Flashing Red

HDSL2 SNR quality is optimum (6 dB or higher)
HDSL2 SNR quality is marginal (1-5 dB)
HDSL2 SNR quality is poor (0 dB)
HDSL2 Pulse Attenuation is >30 dB

STAT

{

z

2

z

Off
Green
Flashing Green
Red

Indicates loss of power to the H2TU-R
Normal; HDSL2 synchronization with H2TU-R
Acquiring HDSL2 synchronization with H2TU-R
Failure indication; unable to start/load firmware

RLOS

{

z

Off`
Red

DS1 signal from CPE is present at H2TU-R
DS1 signal from CPE is absent at H2TU-R or 

framing does not match

HLOS

{

z

2

Off
Red
Flashing Red

HDSL2 synchronization achieved
HDSL2 loss of synchronization
DC continuity fault detected on HDSL2 loop

HCRC

{

z

z

Off
Yellow
Red

No HDSL2 CRC errors within last 30 minutes
Four or more HDSL2 CRC errors in last 30 minutes
HDSL2 CRC errors are being detected

ARM/

LBK

{

z

z

Off
Green
Yellow

No loopback active
Loopback is active on this module
Module is armed but loopback is not active

B8ZS

{

z

Off
Green

AMI line code
B8ZS line code

61221002L2-22E

0612

HDSL2

H2TU-C for Litespan

®

 Using Narrowband Pairs