ADTRAN D4 DS0 DP Скачать руководство пользователя страница 1

Section 61109.003L1-5A

Issue 1, January 1997

CLEI Code D4D2T1W_ _ _

ADTRAN Model D4 DS0 DP

SD4/Performance Monitoring

GENERAL

• For use in all D4 channel bank and SLC 96 terminal applications

• NEAR and FAR logic level bantam test access

• Non-intrusive monitoring of received data from NEAR or FAR direction

• Switched 56k tandem signaling option

• Error correction, latching loopback, and zero code suppression options

• Remotely provisionable; compatible with Performance Monitoring and

Digital System-6 interfaces

OPTIONS

• ERROR CORRECTION is enabled by turning SW1-1 on.

• Select the appropriate RATE from switches SW1-2 to SW1-5.  Only one rate switch should be turned on.

• Select SWITCHED 56 (SW1-6) to maintain A and B bit signaling between two carrier system timeslots.  When in the off

position, data is passed transparently between carrier timeslots.

• Select the appropriate BANK TYPE from switches SW3-1 to SW3-3.  Only one of these switches should be turned on.

• ZERO CODE SUPPRESSION is enabled by turning switch SW3-4 on.

• LATCHING LOOPBACK is enabled by turning switch SW3-5 on.

LED INDICATORS

• REM (Remote Provisioning):  On indicates unit has been remotely provisioned, flashing indicates remote control link is

active.  Push AP (Alternate Provisioning) button to toggle between manual and remote provisioning.

• PM (Performance Monitor):  Indicates unit has established PM link with PM channel bank commons

• LB (Loopback): Indicates latching DS0 or DS1 loopback activation

TESTING

The ADTRAN DS0 DP SD4/PM is equipped with logic level bantam test access jacks that permit testing in both
directions using a portable test set.  Choose NEAR to test toward the 4-wire office signal direction; choose FAR to
test toward the T-carrier.

In the FAR direction, a DS0 DP latching loopback sequence for the first DSO DP will loop the unit directly connected
to the test set.  In the NEAR direction, a DS0 DP latching loopback sequence for the first DS0 DP will be transmitted
across the 4-wire interface to the tandem DS0 DP unit.

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

Rx

Tx

AP

REM

PM

LB

L

O

G

I

C

DS0 DP

1109003L1

SD4/PM

The ADTRAN D4 DS0 DP SD4/PM provides the interface between the WECO-compatible
D4 channel bank or SLC 96 terminal and the standard DS-0 4-wire central office signal.  The
DS0 DP may be used to interoperate with another DS0 DP or OCU DP across a T-carrier
system or interface other DS-0 level equipment such as a multipoint junction unit (MJU) or
subrate multiplexer unit (SRMU).  Either DS-0A or DS-0B formatted signals are accepted by
the DS0 DP.  In SW56 mode, the ADTRAN DS0 DP SD4/PM will maintain A and B bit
signaling between two carrier systems.  The unit can be remotely provisioned through
ADTRAN Performance Monitoring and Digital System 6 interfaces.

PRACTICES

61109.003L1-5A

Trademarks:

Any brand names and product names included in this document are trademarks, registered trademarks, or trade names of their respective
holders.