background image

61280012L1-10A 

© ADTRAN, 2002 

ADTRAN Tracer 3202 Cable Kit Instructions 

 

Background 

Newer models of the Tracer 3202 outdoor unit will have 1.5 to 2 meters of twisted pair cable 
(“pigtail”) preattached to the 3202 base.  The twisted pair conductors are pre-stripped and ready 
for crimping and attachment to a receptacle connector.  A receptacle connector kit is available 
that will mate to existing customer-end cable connectors used with the original 3202 model.  The 
contents of this kit include: 

• 

1 CPC (circular plastic connector) receptacle 

• 

1 CPC strain relief 

• 

4 receptacle crimping pins (male gender) 

The instructions described in this document refer to the 3202 pre-attached cable only.  For 
instructions on attaching the plug connector to the customer cable, please consult the Tracer 
2210/3202 System Manual (provided on the Tracer 2210/3202 Documentation CD).  
 

Directions 

Figure 1 shows a detailed view of the connector assembly required to attach the receptacle 
connector to the pre-attached 3202 cable.  The plug connector assembly is shown for reference 
only. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure 1 – Connector Assembly Diagram 

 
The provided 3202 pigtail cable has heat shrink tubing on conductor pairs 1 and 2.  Insert the 1,2 
pair in the 1,2 slots in the receptacle, without regard to which conductor is wired to conductor 1 
or conductor 2.  Likewise, insert the 3,4 pair in the 3,4 slots in the receptacle, without regard to 
which conductor is wired to conductor 3 or conductor 4. 
 

2 3 

Detail B – B 

Detail A – A

A

A

1
2
3
4

1

2
3
4

P1 P2 

Schematic 

P1 

P2 

x 2 

B

B

2 3 

Plug Connector 

(Customer end) 

Receptacle Connector with Strain Relief 

(3202 end)

3202 Pigtail Cable 

Customer Cable 