background image

6

Section 61150219L1-5, Issue 1

61150219L1-5A

N

O

I

T

I

D

N

O

C

S

Y

A

L

E

R

D

E

T

A

V

I

T

C

A

R

E

H

T

O

R

J

M

R

V

J

M

M

L

A

8

4

m

r

a

l

A

d

e

R

m

r

a

l

A

w

o

l

l

e

Y

m

r

a

l

A

S

I

A

n

w

o

l

B

e

s

u

F

U

A

P

s

e

t

a

v

i

t

c

a

e

D

O

C

A

X
X
X

X

1

X

2

X
X
X

X

1

X

X

1

y

l

n

o

,

2

L

8

7

0

0

5

1

1

N

/

P

,

2

t

s

i

L

U

A

P

2

e

s

u

f

n

w

o

l

b

a

g

n

i

r

u

d

R

J

M

e

t

a

v

i

t

c

a

e

d

t

o

n

s

e

o

d

O

C

A

Shelf Alarm

The –48V alarm  (–48ALM) located on JP15, pin 6,
provides a –48VDC signal when the PAU fuse is
tripped.

Power Connections

The BR1/10 Wall Mount Chassis provides a three-
position terminal strip, JP16, on the backplane for
power connections .  Ring lug terminations are
recommended for connecting to  JP16.  When using
the ADTRAN Wall Mount Power Supply, part
number 1150101L1, insert the –48V wire (BLACK)
into terminal 3 (–48I) of JP16.  Insert the  return wire
(RED) into terminal 2 (–48R). Insert the frame
ground wire (GREEN) into terminal 1 (FG).   See
Figure 10.

Since the frame ground and the –48V return
are isolated in the bank, these grounds
should be connected externally to a central
ground.

OPTIONS

RS-485 Connection

The RS-485 link connection is made on JP17, pins 1
through 3, located on the bottom of the backplane.
This connection is provided for future applications.

LOC CK

When BITS is not available, JP17, pins 4 and 5,
provide a phase-locked-loop local composite clock
output.  While not intended to provide multiple
outputs, this output can be used to provide a clock
source for a single channel bank when an external
output is required.  This option can be used in a
tandem configuration that does not have a centralized
composite clock source.

When necessary wiring and connections are
completed, replace the clear plastic cover on the
backplane.  The common equipment and channel units
may then be configured and installed.  Refer to the
appropriate ADTRAN Practices for information
specific to each plug-in card.

3. MAINTENANCE

The BR1/10 Chassis requires no routine maintenance
to operate properly.  Test and maintenance for the
specific plug-ins should be conducted in accordance
with the recommendations and procedures prescribed
in associated Installation and Maintenance Practices.

ADTRAN  does not recommend that repairs be
performed in the field.  Repair services are obtained
by returning the defective unit to ADTRAN's
Customer Service.

4. SPECIFICATIONS

Refer to Table 3 for unit specifications.  Table 4
contains part number references.

5. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within ten
years from the date of shipment if it does not meet its
published specifications or fails while in service (see
ADTRAN Telco Network Equipment Warranty, Repair,
and Return Policy and Procedure, 
document
60000087-10A).

Contact Customer and Product Services (CAPS) prior
to returning equipment to ADTRAN.

Figure 10.  Power Connections on JP16

Table 2.  Alarm Notifications

JP16

1

GREEN

FG

RED

GRD

BLACK

–48V

POWER

SUPPLY

Содержание BR1/10

Страница 1: ...xtending Basic Rate ISDN services to a customer s premise or equipment closet The chassis terminates a single T1 and provides mounting for one set of BR1 10 commons BCU LIU and PAU and 10 U BR1TE channel units The compact fold down design of the unit allows quick and easy installation to most indoor walls The assembly includes two components an 11 inch BR1 10 chassis and a wall mounting bracket Th...

Страница 2: ... for each of the 10 channel slots The 13 36 pin card edge connectors are used for BR1 10 common equipment and channel units The three position terminal strip labeled JP16 supplies power connections The two terminal barrier strip labeled JP18 is for future enhancements 2 INSTALLATION After unpacking the unit immediately inspect it for possible shipping damage If damage is discovered immediately fil...

Страница 3: ... r f t u p n i g n i R 1 X S D k r o w t e n e h t m o r f t u p n i p i T 1 X S D k r o w t e n e h t m o r f t u p t u o g n i R 1 X S D k r o w t e n e h t m o r f t u p t u o p i T 1 X S D 1 X S D r o f d l e i h s e l b a C d n u o r G d l e i h S t u p t u o m r a l A C D V 8 4 d e p p i r t e s u f U A P n e h w C D V 8 4 m r a l a k n a b g n i r u d e d i r r e v o s e d i v o r p O C A s...

Страница 4: ... 45 20 46 21 47 22 48 23 49 24 50 25 CHANNEL 1 CHANNEL 1 CHANNEL 1 CHANNEL 1 R T CHANNEL 2 CHANNEL 2 CHANNEL 2 CHANNEL 2 R T R1 T1 R1 T1 CHANNEL 3 CHANNEL 3 CHANNEL 3 CHANNEL 3 R T R1 T1 CHANNEL 4 CHANNEL 4 CHANNEL 4 CHANNEL 4 R T R1 T1 CHANNEL 5 CHANNEL 5 CHANNEL 5 CHANNEL 5 R T R1 T1 CHANNEL 6 CHANNEL 6 CHANNEL 6 CHANNEL 6 R T R1 T1 CHANNEL 7 CHANNEL 7 CHANNEL 7 CHANNEL 7 R T R1 T1 CHANNEL 8 CHA...

Страница 5: ...s during a bank alarm condition providing a means to control an external Audible Alarm No other alarm contacts are affected by the ACO pushbutton The BR1 10 PAU List 2 P N 1150078L2 provides alarm relay contact closure in the event the 48V PAU faceplate fuse is tripped In this alarm condition the relay contacts will close in the same manner as if the BR1 10 was in a Carrier alarm condition but dep...

Страница 6: ...While not intended to provide multiple outputs this output can be used to provide a clock source for a single channel bank when an external output is required This option can be used in a tandem configuration that does not have a centralized composite clock source When necessary wiring and connections are completed replace the clear plastic cover on the backplane The common equipment and channel u...

Страница 7: ... R 0 4 8 5 1 o t F 0 4 0 7 o t C 0 4 5 8 1 o t F 0 4 5 8 o t C g n i s n e d n o c n o n x a m 5 9 L A C I S Y H P s n o i s n e m i D p U n w o D 8 3 5 1 D 2 1 5 x H 8 5 1 1 x W D 8 3 2 1 x H 5 x W 8 3 5 1 t h g i e W d e d a o l y l l u f b l 5 2 1 Table 4 Part Number Reference R E B M U N T R A P N A R T D A N O I T P I R C S E D 1 L 9 1 2 0 5 1 1 s n o m m o C o N s i s s a h C t n u o M l l a...

Страница 8: ...8 Section 61150219L1 5 Issue 1 61150219L1 5A 2 13 16 BR1 10 WALL MOUNT MOUNTING TEMPLATE 61150219L1 5 Issue 1 May 1998 10 Drill Holes é This Side Up é ...

Отзывы: