2
Section 61150219L1-5, Issue 1
61150219L1-5A
3. Install lag bolts leaving a ˘ inch space between the
plywood and the head of the bolts.
4. Place assembly on the bolts.
5. Tighten down the bolts using the wrench.
Connections
Before making the electrical connections, fold the
chassis down to expose the backplane by following
these steps:
1. Lock the right knob, located on the side of the
assembly, by pulling the knob out and rotating
counter-clockwise until it has locked open. See
Figure 2 for an illustration.
2. With the right knob locked open, pull the left
knob outwards and rotate the chassis to the down
position. Release the knob allowing the chassis to
lock into place.
3. Using a small phillips head screwdriver, remove
the four (4) back panel screws and remove the back
panel.
4. Make appropriate connections outlined in the
following sections.
5. After the electrical connections have been made,
route all wiring through the semi-circle opening in the
back panel and secure with four (4) screws.
6. Route cable ties (provided) through the cable tie
holes on the right side of the assembly (see Figure 2)
and loosely secure cables.
edge connectors, (1) three-terminal barrier strip, (1)
two-terminal barrier strip, and (1) female DB-9
connector. The 50-pin male amphenol connector
interfaces with the T/R and T1/R1 connections for
each of the 10 channel slots. The (13) 36-pin card
edge connectors are used for BR1/10 common
equipment and channel units. The three-position
terminal strip, labeled JP16, supplies power
connections. The two-terminal barrier strip, labeled
JP18, is for future enhancements.
2. INSTALLATION
After unpacking the unit, immediately inspect it for
possible shipping damage. If damage is discovered,
immediately file a claim with the carrier and then
contact ADTRAN Customer Service (see Warranty
and Customer Service).
Tools Needed
The ADTRAN BR1/10 Wall Mount Chassis includes
a mounting template for installation on a 3/4" thick
plywood surface which is secured to an existing wall.
The unit is intended only for indoor use. The
following is a list of tools/hardware needed for
installation:
•
Mounting hardware (4-1/4" x minimum 1" lag
bolts)
•
Drill and drill bits
•
Wrench
•
Phillips head screwdrivers (small and medium)
•
Wire-wrap gun (T1 connection)
•
25-pair male amphenol cable (customer connec-
tion)
•
Selected punch down block
Existing wall construction should be
capable of supporting wall mount cabinet
and associated equipment.
Mounting the Assembly
Before beginning the installation, locate the mounting
template found on the last page of this practice and
complete the following steps:
1. Place mounting template on plywood in the
desired location of the assembly.
2. Drill four pilot holes on plywood as detailed on
the mounting template.
Figure 2. BR/10 Mounting
To Lock:
Pull Knob & Turn
Counter-Clockwise
1150219L1
Cable Tie
Hole