Quick Start Guide, 61700412E1-13A, December 2006
Copyright © 2006 ADTRAN, All Rights Reserved
For more detailed documentation, visit us online at
www.adtran.com
.
Quick Start Guide
®
NetVanta 150 Wireless Access Point
P/N 1700412E1
I
NSTALLING
THE
A
NTENNAS
The NetVanta 150 unit ships with two dual-band RP-SMA detachable antennas. These must be
installed before operating the unit.
1.
Place either of the two antennas directly onto the antenna port on the rear panel labeled
Antenna 1
. See Rear Panel figure above to locate the ports on the rear panel.
2.
Twist the antenna onto the threads until it is secure.
3.
Repeat step 2 with the second antenna, attaching it to the
Antenna 2
port.
S
UPPLYING
P
OWER
TO
THE
N
ET
V
ANTA
150 U
NIT
The NetVanta 150 unit can be powered either by the Power over Ethernet (PoE) connection or
through the 12 VDC external supply. The external supply is not included in shipment of this unit but
can be requested from ADTRAN or your reseller.
C
ONNECTING
TO
THE
N
ET
V
ANTA
150 U
NIT
Using the provided Ethernet cable, connect the
ETH 0/1
port on the back of the NetVanta 150 unit
to the Ethernet port of the NetVanta controlling unit or to an Ethernet port on a unit that is
accessible by the controlling unit .
A
CCESSING
THE
C
ONFIGURATION
W
IZARD
The web-based graphical user interface (GUI) for your NetVanta controlling unit contains a
configuration wizard that leads the user through the basic configuration of the dynamically
discovered access points. Refer to the Quick Start Guide shipped with your NetVanta controlling
unit for instructions on accessing the GUI and configuring the unit’s IP address. From the initial GUI
screen, expand the
Data
tab on the right side of the screen. Select
AC/AP
under the
Wireless
menu. Select the
Wizard
button next to the desired discovered access point.
The 10/100BaseT Ethernet interface (ETH 0/1)
MUST NOT
be metallically connected
to interfaces that connect to the Outside Plant (OSP) or its wiring. This interface is
designed for use as an intrabuilding interface only. The addition of primary protectors
is not sufficient protection to connect this interface metallically to OSP wiring.
N
ET
V
ANTA
150 F
RONT
P
ANEL
Factory Default Switch
N
ET
V
ANTA
150 R
EAR
P
ANEL
Wizard