job
Aid
1
D
ESCRIPTION
The ADTRAN 100Base-TX, RJ-45 Copper Small Form-Factor
Pluggable (SFP) plugs into appropriate ADTRAN Ethernet
modules to provide a 100Base-TX interface over an RJ-45 type
copper connector.
The SFP supports the following features:
■
100Base-TX compliant
■
Auto-Negotiation: full-duplex or half-duplex
■
Uses Category 5 or 5e shielded twisted-pair cable (or better)
NOTICE
The SFP may not operate in all SFP-based Ethernet modules. To
determine if the SFP is appropriate for use in a particular module,
refer to the documentation for that module, or contact ADTRAN
Customer Support.
NOTE
The SFP does not support Auto-MDIX.
I
NSTALLATION
Prior to installation, inspect the SFP. If damage has occurred
during shipping, file a claim with the carrier, and then contact
ADTRAN Customer Support. Refer to
To install the SFP into an appropriate module, complete the
following steps:
1.
If present, remove the safety cap from the connector of the SFP.
2.
Insert the SFP into the SFP cage of the host module, with the
removal latch facing outward. Slide the SFP all the way into the
cage.
3.
Firmly squeeze the receptacle and SFP together, to ensure a
proper connection.
NOTE
The latch on the SFP is for removal only.
4.
Continue the installation and turn-up of the host
module using the instructions in the documentation
provided with the module or other system-level
documentation available online at
www.adtran.com
.
Small Form-Factor Pluggable,
100Base-TX, RJ-45 Copper
S
PECIFICATIONS
■
General
♦
Module type: SFP
♦
Media Type: Copper
♦
Signal data rate: 1.25 Gbps
♦
Applications: Migration and integration of transport in
packet switching networks
♦
Diagnostic Monitoring: No
♦
Distance: Maximum (over Cat 5 cable): 100 meters
■
Operates in modules supporting the following voltage inputs
♦
±24 VDC Nominal (±20.0 VDC to ±28.3 VDC)
♦
–48 VDC Nominal (–40.0 VDC to –56.7 VDC)
■
Environmental
♦
Protected Equipment Environment (Outside)
●
Operational temperature range: –40°C to +65°C
●
Storage temperature range: –40°C to +85°C
●
Relative humidity: 5 to 85%
■
Extended environmental support
♦
Controlled Protected Environment (Inside)
●
Operational temperature range: –5°C to + 55°C
●
Storage temperature range: –40°C to +85°C
●
Relative humidity 5 to 85%
M
AINTENANCE
The SFP does not require routine hardware maintenance for
normal operation. ADTRAN does not recommend that repairs be
attempted in the field. Repair services may be obtained by
returning the defective unit to ADTRAN. Field support for
software is provided through upgrade facilities. Refer to
for further information.
CLEI: SOUIBVOL_ _
Product P/N: 1442200G1
Issue Date: November 2018
Document P/N: 61442200G1-22B