ADTRAN 1221045L2 Скачать руководство пользователя страница 1

61221045L2-5A

1

239 H2R-PSD

2-Wire High Bit Rate Digital Subscriber Line Repeater

Installation and Maintenance

Section 61221045L2-5A

Issue 1, December 2002

CLEI Code: T1R6VJWD_ _

CONTENTS

1.

GENERAL .......................................................... 1

2.

INSTALLATION ............................................... 2

3.

FRONT PANEL FEATURES ............................ 4

4.

DEPLOYMENT GUIDELINES ........................ 5

5.

MAINTENANCE ............................................... 6

6.

SPECIFICATIONS ............................................ 7

7.

WARRANTY AND CUSTOMER SERVICE ... 7

Appendix A. HDSL2 Loopbacks ........................... A-1

FIGURES

Figure 1.

ADTRAN 239 H2R ................................. 1

Figure 2.

Card Edge Pin Assignments ..................... 2

Figure 3.

First Segment Deployment Guidelines .... 5

Figure 4.

Second Segment Deployment
Guidelines ................................................ 5

TABLES

Table 1.

Compliance Codes ................................... 2

Table 2.

239 H2R Capacity Guidelines ................. 3

Table 3.

LED Indications ....................................... 4

Table 4.

First Segment Loop Insertion
Loss Data .................................................. 6

Table 5.

Second Segment Loop Insertion
Loss Data .................................................. 6

Table 6.

ADTRAN 239 H2R Specifications .......... 7

Table A-1. In-Band Addressable Loopback

Codes .................................................... A-2

Figure 1.  ADTRAN 239 H2R

Trademarks: Any brand names and product names included in this document are

trademarks, registered trademarks, or trade names of their respective holders.

1. GENERAL

This practice provides installation and maintenance
instructions for the ADTRAN Enhanced PSD 239 T1
HDSL2 Repeater (ADTRAN P/N 1221045L2).

Figure 1

 is an illustration of the H2R equipment

which includes these features:

• Enhanced PSD

• HDSL2 line coding

• Lightning protection

• In-band loopback control

• Designed for use in standard DDS or ISDN

repeater apparatus case (239 mechanics)

• Remote provisioning and pass-through

performance monitoring

The ADTRAN Enhanced PSD 239 H2R can
effectively extend the deployment range of the
HDSL2 loop up to 17 kft over 26-AWG cable.
Compatible ADTRAN HDSL2 transceiver units are as
follows:

Part Number

Unit Name

1181111LX ............. Total Access 3000 H2TU-C

1181112LX ............. 2

nd

 Generation Total Access

3000 H2TU-C

1221001LX ............. 220/E220 H2TU-C

1221003LX ............. DDM+ H2TU-C

1221004LX ............. 3192 H2TU-C

1221007L4 ............. Soneplex

®

 H2TU-C

1222001LX ............. 2

nd

 Generation 220/E220

H2TU-C

1222003LX ............. 2

nd

 Generation DDM+

H2TU-C

1222004LX ............. 2

nd

 Generation 3192

H2TU-C

1222007L4 ............. 2

nd

 Generation Soneplex

H2TU-C

1222026L9 ............. Enhanced PSD T200

H2TU-R

239 H2R

1221045L2

DSL

DSL

CUST

NET

LL

(Y)

RL

(G)

Содержание 1221045L2

Страница 1: ...s registered trademarks or trade names of their respective holders 1 GENERAL This practice provides installation and maintenance instructions for the ADTRAN Enhanced PSD 239 T1 HDSL2 Repeater ADTRAN P...

Страница 2: ...the unit inspect it for damage If damage is discovered file a claim with the carrier then contact ADTRAN Refer to Warranty and Customer Service Compliance Table 1 lists the Compliance Codes for the 2...

Страница 3: ...A R 1 O E E O M D D A R 1 O E F O M D D 8 l e e t S s s e l n i a t S e r o c r i A d e l l i f l e G 9 1 8 9 3 4 9 3 2 8 8 N A R T D A t o l S 6 1 1 L 6 1 8 0 9 1 1 2 L 6 1 8 0 9 1 1 3 L 6 1 8 0 9 1...

Страница 4: ...a u n e t t a d l o h s e r h T m r a l A B d 0 n a h t r e t a e r g n i g r a m R N S n a h t i w d e z i n o r h c n y S n i g r a m R N S n a h t i w d e z i n o r h c n y S d n o c e s r e p e m...

Страница 5: ...able the maximum loop length including bridge tap lengths is 8 kft 3 For loops with 24 AWG cable the maximum loop length including bridged tap lengths is 11 kft 4 Any single bridge tap is limited to 2...

Страница 6: ...gh the channel allowing digital loopback in fault isolation The looping is accomplished remotely as defined in Appendix A of this practice Performance monitoring diagnostics and loopbacks are also ava...

Страница 7: ...2 Repair and Return Address ADTRAN Inc CAPS Department 901 Explorer Boulevard Huntsville Alabama 35806 2807 Loop Interface Modulation Type 16 TC PAM Mode Full duplex partially overlapped echo cancelin...

Страница 8: ...8 61221045L2 5A...

Страница 9: ...general the loopback process for the HDSL2 system elements is modeled on the corresponding DS1 system process Specifically the H2TU C loopback is similar to an Intelligent Office Repeater loopback and...

Страница 10: ...it error confirmation is sent 2 seconds of AIS all 1s will be sent 5 seconds of data will pass and then 200 bit errors will be injected into the DSX 1 signal As long as the pattern continues to be sen...