Unit Installation
NetVanta 3200/3300/3400 Series
58
Copyright © 2019 ADTRAN, Inc.
61200860L1-34AE
4.
UNIT INSTALLATION
The instructions and guidelines provided in this section cover hardware installation topics, such as wall
mounting/rack mounting the unit and installing option cards. These instructions are presented as follows:
•
•
Supplying Power to the Unit on page 64
•
Installing Dial Backup and Network Interface Modules on page 69
•
Using a USB Cellular Modem with the NetVanta USB WWAN NIM on page 72
•
Installing the NetVanta VPN Accelerator Card (included in P/N 4200368L1) on page 73
•
Installing SODIMM for Expandable Memory on page 74
For information on router configuration for a specific application, refer to the configuration guides provided on
the
ADTRAN Support Community
. For details on the command line interface (CLI), refer to the
Command Reference Guide
. All other related documents are also available online at
http://supportforums.adtran.com
.
The NetVanta 3200/3300/3400 Series is intended to be installed, maintained, and serviced
by qualified service personnel only and should be installed in a restricted access location
as described in UL/IEC 60950-1.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Tools Required
The customer-provided tools required for the hardware installation of the NetVanta 3000 Series are:
•
Ethernet cable
•
Network cable (module dependent)
•
DSX-1 cable (T1/FT1 + DSX-1 module only)
•
DBU cable (dial backup functions require an optional DIM)
•
Phillips-head screwdriver (rack mounting applications only)
• PoE cables are intended for intrabuilding use only. Connecting an ADTRAN PoE
unit directly to PoE cables that run outside the building in which the unit is
housed will void the user's warranty and could create a fire or shock hazard.
• Ethernet cables are intended for intrabuilding use only. Connecting an ADTRAN
unit directly to Ethernet cables that run outside the building in which the unit is
housed will void the user's warranty and could create a fire or shock hazard. To
connect an ADTRAN unit to Ethernet cables that run outside the building,
ADTRAN's Ethernet Port Protection Device (EPPD) (P/N 1700502G1) must be
connected between the unit and the outside plant cable. Use of any Ethernet
protector other than ADTRAN's for this purpose will void the user's warranty.