T3SU ETHERNET BRIDGE OPTION MODULE
P/N 1200655L1
For more detailed documentation, visit us online at
www.adtran.com
Quick Start Guide
Quick Start Guide, 61200655L1-13A, October 2002
Technical Support 1-888-4ADTRAN (1-888-423-8726)
Copyright
2002 ADTRAN, All Rights Reserved
S
PECIFICATIONS
Interface Type:
(4) 10BaseT/100BaseTX interfaces with auto MDI/MDIX
crossover on all interfaces
Flow Control:
Back-pressure flow control on all half-duplex interfaces
Pause-frame flow control on full-duplex interfaces
Environmental
Specifications:
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: Up to 95% non-condensing
Compliance:
FCC Part 15, Class A
UL 60950, 3rd Edition
EN 60950
ETSI 300 386
N
ETWORK
C
ONNECTION
P
INOUT
Pin
Name
Description
1
TX1
Transmit Positive
2
TX2
Transmit Negative
3
RX1
Receive Positive
4, 5
UNUSED
—
6
RX2
Receive Negative
7, 8
UNUSED
—
1st Generation T3SU's (AC P/N 1200217L2 and DC P/N
1200217L4) can support a single Ethernet Bridge Module.
2nd Generation T3SU's (AC P/N 1202217L2 and DC P/N
1202217L4) can support up to 3 Ethernet Bridge Modules.
1
2
3
4
LINK
ACT LINK
ACT LINK
ACT LINK
ACT
10/100 BASE T/TX INTERFACE
I
NSTALLATION
I
NSTRUCTIONS
1. Remove the cover plate from the appropriate option slot in the T3SU
Base Unit.
2. Slide the T3SU Ethernet Bridge Option Module into the option slot until
the module is firmly positioned against the front of the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a
screwdriver.
4. Connect the cables to the associated device(s).
5. Complete installation of remaining modules and Base Unit as specified
in the T3SU User Manual.