Chapter 3. Operation
61200310L1-1
Octal and Quad FXO Modules User Manual
3-3
Figure 3-2. Menu Tree for Octal and Quad FXO Modules Menu
S
LT
Read security: 5
Displays the number of the available slots in the ATLAS 550 chassis. Slot 0
refers to the ATLAS 550 unit. This field is read-only.
T
YPE
Write security: 3; Read security: 5
Displays the type of module currently installed in the slot or the type of
module you plan to install in the slot. If an Octal or Quad FXO Module is
installed, the
T
YPE
field automatically defaults to
FXO-8
.
You can use this field to preconfigure a system before actually installing
modules by simply specifying the module that you want to install in each
slot. If you intentionally leave a slot empty, mark it as
E
MPTY
to avoid get-
ting a message that the module is not responding.
Slt
Part Number
Serial Number
Type
Info
Board Revision
Assembly Revision
Menu
Alarm
Port
Status
Status
Modules
Rx ABCD
Test
(Shortcut to Test)
Tx ABCD
Port
Test 2W
Test
Tx ABCD
1kHz Tone
State
Port
Loopback
Port Name
Configuration
Rx Gain
0 dB through -6 dB
Tx Gain
3 dB through -6 dB
Status
2W Impedance
600 +2.16
µ
Rev
Coding Scheme
µ
-law
T
YPE
automatically displays the name of an installed module. If
you want to preconfigure the slot for a different type of module,
you must set this field to
E
MPTY
before selecting another module
type.