Control Port Operation
HDSL4 for General Distribution Installation and Maintenance Practice
30
61223HDSL4L2-5C
NOTE
The T1 alarm indications displays if the External Alarms option is
set to “Enabled” on the Provisioning
menu (
The Auto In Service Status screen also indicates the startup or exit period remaining as either
1, 4, 8, or 24 hours. This is the time during which the unit monitors both loop synchroni-
zation (Loop Sync) and T1 alarms (if enabled) and only goes into (or out of) service if the circuit
remains synchronized and without T1 alarms during the entire measured period. These times
are also set from the Provisioning menu
.
A link is provided to view the Alarm History Screen. The Alarm History Screen screen is also
available by selecting the HDSL4 Main Menu opti
on.
System responses displayed in the status fields on the Alarm History Screen are shown in
Table 10. Auto In Service Status Indications
Status Field Name
System Indications
Current Auto In Service State (line 1)
In Service
Out-of-Service Maintenance
Auto In Service Status (line 2)
Currently in startup period
Currently in exiting period
OK, Startup Period COMPLETED
OK, Startup INCOMPLETE (forced in-service)
Auto In Service Criteria (line 3)
DSL Loop Sync (T1 alarms ignored)
DSL Loop Sync and absence of T1 alarms
Criteria (current status)
DSL Loop Sync = OK or LOS (LOS shown in
T1 Alarm Status = Alarm or OK