Note:
OUT terminal for the output signal, the general proximity switch selected working power
10-30V, and the NPN output, photoelectric switches is similar.
Common input interface, based on the level of public input conditions corresponding to
the input active level is different.
Input
Terminal
EXT_24V
INPUTCOM
INPUT
(
a
)
Public grounded, input active high
Input
Terminal
INPUTCOM
INPUT
EXT_24V
EXT_24V
(
b
)
Public termination high, input active low
Figure 5-4
Input terminal INPUTCOM side wiring