ADT Model 927 Water Recycling System
P/N 90927-SPPM-000-00
vii
Figure 3-7. Bag-filter
Inspect the filter O-rings.
If they are damaged or dry– replace them.
If not– apply some grease or other lubricant to ensure good sealing.
Insert the bag-filter into the filter body.
Re-assemble the filter body to the filter base.
Rotate the filter drain valve to its closed orientation.
3.4
Replacing the filter modules
Disconnect the light-tower cable.
Open the 12 screws connecting the System top cover, and remove it.
Perform the following procedure on both filter modules.
To remove the filter element:
Open the screw connecting the yellow locker, and remove the locker.
Figure 3-8. Filter locker
Open and release the pipes connected to the filters.
Using a large flathead screwdriver, remove the white holding ring.