background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instruction manual 

Machine Mounted Displays 
MMD9016

 

 

 

 

 

 

 

Translation of the original 

instruction manual  

Version 1.3  

Updated on 2021-04-20 

Содержание MMD9016

Страница 1: ...Instruction manual Machine Mounted Displays MMD9016 Translation of the original instruction manual Version 1 3 Updated on 2021 04 20...

Страница 2: ...rticular about its intended use safety installation utilisation maintenance and disposal Hand over the instructions to the user following installation of the product and pass the manual on to the new...

Страница 3: ...details 8 2 2 Intended use 8 2 3 Improper use 8 2 4 Environmental conditions 10 2 5 Conformity 11 2 6 Warranty repairs 11 2 7 Limitation of liability 11 3 Scope of delivery 12 4 Interfaces 13 4 1 Int...

Страница 4: ...All users must read this instruction manual and have access to it at all times The original version of this instruction manual was written in German All non German versions of this instruction manual...

Страница 5: ...r severe injury could result CAUTION Indicates a possible danger If not avoided light or minor injuries could result ATTENTION Indicates a possibly damaging situation If not avoided the system or some...

Страница 6: ...vices must not be disposed of with household waste but must rather be taken to a collection point for waste electrical equipment Such a collection point is generally operated by public waste managemen...

Страница 7: ...For the authorised user simple usage rights are granted within the scope of the intent of the contract Any modified use or exploitation of the provided content particularly duplication modification o...

Страница 8: ...ohibited 2 3 Improper use Operation other than or beyond that described for the device shall be deemed improper use The device is not allowed to be used to control vehicles or for applications for whi...

Страница 9: ...GmbH Heinrich Hertz Str 1 72622 N rtingen Germany The device can be damaged as a result of unauthorised mechanical modifications Make sure that the device is not drilled chiselled or perforated and i...

Страница 10: ...used If however the device is to be used in aseptic environments a suitability test must be conducted and where necessary the manufacturer consulted ATTENTION Damage caused by heat If the device is i...

Страница 11: ...ad area 2 6 Warranty repairs During the device warranty period any repairs must only be performed by the manufacturer or by service personnel that has been authorised by the manufacturer 2 7 Limitatio...

Страница 12: ...hat the contents of the package are intact If there are signs of damage please contact the manufacturer immediately The device must not be put into operation Check that the contents of the package are...

Страница 13: ...GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 4 Interfaces 4 1 Interface overview 1 Display port or HDMI for transmitting the image signal 2 USB 2 0 type B slave for transmitting the signals from...

Страница 14: ...olated from the housing Conductor cross sections AWG 18 1 mm2 or AWG 16 1 5 mm2 With cable lengths 5 m the larger of the two cross sections must be selected 4 1 2 Earthing concept ATTENTION Risk of ra...

Страница 15: ...chanical installation 5 1 Requirements Requirement regarding installation location ATTENTION Damage caused by heat If the device is exposed to sunlight or any other light or heat source it can overhea...

Страница 16: ...ly along each edge from the outside to the inside in order to avoid rippling ATTENTION To maintain the IP protection class Insert the flange seal the right way round The side with the double lip shoul...

Страница 17: ...interface for VESA 75 and VESA 100 1 Press the flange seal evenly into the groove on the housing side cf 5 2 2 Guide all cables through the openings in the seal flange and rear cover and plug in all c...

Страница 18: ...v1 3 18 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 4 Screw down the seal 5 Screw on the rear cover in a crosswise sequence in two stages Tool 8 mm spanner torque 3 5 Nm 3...

Страница 19: ...nt to a bottom mounted tube For example by screwing the retaining screws or threaded pins into the tube so that they lock positively in it make drill holes or countersinks To prevent the screws thread...

Страница 20: ...nge seal into the groove on the housing side cf 5 2 2 Guide all cables through the opening of the adapter and plug in all connectors 3 Secure the cables using a cable tie at the fixtures provided 4 Sc...

Страница 21: ...template instructions also supplied To screw on the adapter you may use the threaded pins ISO4027 M5x8 enclosed with the device However depending on the condition and type of retaining tube provided...

Страница 22: ...slot Make sure that the 24 V power supply complies with NEC Class 2 Connect the device to the power supply ATTENTION Hazard due to condensation Damage to electronic components caused by condensation r...

Страница 23: ...wing cleaning agents have also been successfully tested Ethanol and isopropanol based Deconex Solarsept Bacillol Meliseptol Neutral cleaning agents P3 cosa Foam 40 P3 cosa PUR 80 Quarternary ammonium...

Страница 24: ...MMD9016 Instruction manual v1 3 24 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 N rtingen Germany 9 Dimensional drawings...

Страница 25: ...MMD9016 Instruction manual v1 3 25 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 N rtingen Germany...

Страница 26: ...MMD9016 Instruction manual v1 3 26 ads tec Industrial IT GmbH Heinrich Hertz Str 1 72622 N rtingen Germany...

Страница 27: ...lass 5H Touch surface 346 3 mm x 195 8 mm Controller EETI 3200 Impact resistance IK06 Splinter protection Optional protective film Power supply Voltage 24 VDC 20 19 29 VDC Current max 0 5 A Power max...

Страница 28: ...c will not be able to answer such questions ADS TEC does not provide support services for any device that was not purchased directly from ADS TEC In this case maintenance and support is provided by th...