Страница 1: ...User Manual IT Infrastructure IWL3000 series Version 2 0 Effective as of 10 14 Translation of original instruction manual ...

Страница 2: ...erating and safety instructions 8 3 1 Safety instructions 9 3 2 Operating location 9 3 3 Damage due to improper use 10 3 4 Warranty repairs 10 3 5 General information on the 5GHz version 802 11 A 802 11 H ETSI 10 3 6 WLAN information 10 3 7 Intended use 11 3 8 Improper use 11 3 9 Treatment and disposal of lithium batteries 11 3 10 Safety instructions 12 4 Introduction 13 3 1 Equipment versions 13 ...

Страница 3: ...e update 21 6 3 Interface overview 22 6 3 1 24 V DC power supply 23 6 3 2 LAN 1 RJ45 23 6 3 3 LAN 2 RJ45 24 6 3 4 X1 25 6 3 5 X2 25 6 3 6 USB CONNECTIONS 25 6 3 7 SIM CARD READER IN ACCORDANCE WITH ISO 7816 26 7 Placing into operation 27 7 1 Initial configuration 27 7 2 Manual configuration of the network adapter 28 7 3 Settings for use with Internet Explorer 8 30 7 4 Calling up the device web int...

Страница 4: ...operating company is independently responsible for compliance with and observance of any subsequently introduced technical innovations or new legal requirements as well as for all usual obligations of the operator operating company The original version of this instruction manual was written in German All non German versions of this instruction manual are translations of the German instruction manu...

Страница 5: ...re identified by an arrow 2 3 Explanation of used symbols DANGER Indicates an imminent danger If not avoided death or severe injury will result WARNING Indicates a possible danger If not avoided death or severe injury could result CAUTION Indicates a possible danger If not avoided light or minor injuries could result ATTENTION Indicates a possibly damaging situation If not avoided the system or so...

Страница 6: ...e best of our knowledge They do not represent any assurance for the properties themselves Despite taking utmost care no liability can be assumed for accuracy completeness and actuality of the information Subject to changes 2 6 Trademarks It is noted that any software and or hardware trademarks and any company brand names mentioned in this documentation are all subject to the general trademark prot...

Страница 7: ...068 2 6 testing specifications sinusoidal vibration This unit is compliant to the DIN EN 60068 2 27 shock and bump testing specification This unit is compliant to DIN EN 300 328 V1 8 1 2 4 GHz and DIN EN 301 893 V1 7 1 5GHz Recommendation for use A corresponding declaration of conformity is available for competent authorities at the manufacturer and can be viewed upon request For full compliance w...

Страница 8: ...the warranty is invalidated General information Assembly commissioning and operation may only be performed by qualified and trained personnel The safety notices and the instruction manual are to be observed by all persons who work with the device At the installation site the valid guidelines and regulations for accident prevention must be observed The instruction manual contains the most important...

Страница 9: ...s adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges DIN EN 61340 5 1 DIN EN 61340 5 2 3 2 Operating location This device is designed for industrial use Make certain that the specified environmental conditions are maintained at all times Use in non specified environments i e on board ships in explosive atmospheres or at extreme el...

Страница 10: ...2 11a channels cannot be set permanently Information The lower four channels non DFS can be set permanently if the DFS is switched off Switching off the DFS also results in the 60s Scan and Radar Detection functions being switched off however Upon activation of the Access Point the Access Point performs a one time radar detection scan and then waits for a period of time on an arbitrarily selected ...

Страница 11: ...use ads tec shall not accept responsibility or liability for injury or damage that is directly or indirectly attributable to the handling of the device Should the device have evident signs of damages caused e g by improper operation or storage conditions or due to improper use or handling it must be shut down immediately Ensure that it is secured against being started up accidentally 3 9 Treatment...

Страница 12: ...be caused by electrostatically sensitive components All installation and service work performed on the device must be performed only under safe secure and de energised conditions Recommendation for use Always adhere to the safety measures applicable when handling components at risk of being damaged by electrostatic discharges The provisions of DIN EN 61340 5 1 DIN EN 61340 5 2 apply ...

Страница 13: ... or liability of any kind with respect to the installation application and freedom from errors of any piece of open source software Information For the efficient online configuration of your ads tec devices it is possible to download the current version of the free tool IDA light on the company s homepage http www ads tec de With this tool you can for example define individual parameters or whole ...

Страница 14: ...teness Scope of delivery IWL3000 series 1 x IWL Access Point and Client 1 x 3 pin connector 2 x 4 pin connector 1 x top hat rail holder 1 x mounting set with two of each of the following pan head screw washer serrated lock washer 4 x rubber feet 1 x Ethernet cable 1m red 1 x Quick Start Up Guide Quick Assembly Guide 1 x GNU General Public License ...

Страница 15: ...ds tec cannot be held liable for any damages arising from improper use and handling Ambient temperature during operation 20 to 70 C during storage 40 to 85 C Humidity during operation 5 to 90 without condensate during storage 5 to 90 without condensate Vibration during operation 1 G 10 to 500 Hz DIN EN 60068 2 6 Vibration test MIL STD 810F 514 5 C 2 5 to 500 Hz 01 01 2000 Shock resistance during o...

Страница 16: ...IWL3000 series 16 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 5 Assembly 5 1 Overall device dimensions Fig 1 ...

Страница 17: ...mounting 5 2 1 Table mounting Remove the protective foil on the rubber feet and attach them at the marked positions Fig 1 5 2 2 Wall mounting Alternatively the device can be mounted according to the VESA 75 standard on a suitable mounting surface Fig 2 Information For mounting use M4 screws of a suitable length The usable blind hole depth of the mounting holes is 6mm ...

Страница 18: ...e device is set at an angle from the top of the rail 1 and is fixed by gently pressing on the bottom 2 The device must be felt to snap into the rail Fig 3 To release the device from the DIN rail proceed in reverse order Information Make sure not to damage the mounting rail of the unit when removing it ...

Страница 19: ...allation site The status indicators of the device are shown in the overview LED status Representation Off Green Flashing green Red Orange Flashing orange 6 1 1 PWR CUT ALARM VPN 3G Fig 4 PWR 1 Signal Action This device is not supplied with voltage Indicates POWER ON flashes during booting The device is supplied with voltage via POWER and is ready for operation Status 1 This device is not supplied ...

Страница 20: ...eries 20 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen Abb 5 Link 2 3 Signal Action There is no Wi Fi connection active Search for available WLAN networks Connection established Activity 2 3 Active traffic ...

Страница 21: ...gs Using the Factory Default pushbutton it is possible to reset the firewall back to the default factory settings at any time independent of its configuration To reset the Access Point to the default settings the Factory Default pushbutton must be pressed prior to the boot up process and held down for approx 10 seconds during the boot up process The PWR LED flashes rapidly while resetting to facto...

Страница 22: ...er supply 7 36V 3 pole plug 2 LAN1 RJ45 connection 3 LAN2 RJ45 connection 4 X1 5 X2 6 USB 2 0 connection 7 WPS pushbutton factory default The device is equipped with the following interfaces rear side Fig 7 8 WLAN antenna WLAN module 1 9 SCM card reader read in out the ads tec SIM cards 10 WLAN antenna WLAN module 2 Information All input voltages can be connected redundantly ...

Страница 23: ...y This power supply is fed to the device via a lead through terminal The figure shows the socket inside the device PIN number Signal name 1 24V DC 2 GND 3 PE Technical data of the power adapter Input voltage 7 36V DC 6 3 2 LAN 1 RJ45 PIN number Signal name 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC ...

Страница 24: ...IWL3000 series 24 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 6 3 3 LAN 2 RJ45 PIN number Signal name 1 TX 2 TX 3 RX 4 NC 5 NC 6 RX 7 NC 8 NC ...

Страница 25: ...Name 1 24V DC 2 IN Not Connected 3 OUT Wake Up 4 GND 6 3 5 X2 Pin Nummer Signal Name 1 24V DC 2 IN 3 OUT 4 GND 6 3 6 USB CONNECTIONS The USB interfaces are used for connecting peripherals with USB connection The interface complies with the USB 2 0 standard PIN number Signal name 1 VDC 2 D 3 D 4 GND ...

Страница 26: ...GmbH Heinrich Hertz Str 1 D 72622 Nürtingen 6 3 7 SIM CARD READER IN ACCORDANCE WITH ISO 7816 The SIM card reader is used to store configuration data PIN number Signal name 1 VCC 5 volt 2 RESET 3 CLOCK 4 NC 5 GND 6 NC 7 I O 8 NC ...

Страница 27: ...n to a PC is required Connecting the 24V DC power source The device can be powered with a 24V DC 3 pole plug power source The corresponding plug is included in the scope of delivery of the device Connect the device with an appropriate power source Connecting the RJ45 network cable When placing into operation for the first time a connection is required between the device and a PC via an RJ45 networ...

Страница 28: ...s and properties described here may vary Open the properties map for your network adapter The relative path is as follows Network connections LAN connection Properties right mouse key In the dialogue tab that appears select option Internet protocol TCP IP and then click on Properties Fig 8 Now select Use the following IP address Access to the device is only enabled if the following parameters are ...

Страница 29: ...gits must be a number between 1 and 253 In the example 100 has been selected Once the IP address has been entered the subnet mask address must be entered Click on the Subnet mask field and the correct address is entered automatically Subnet mask 255 255 255 0 The dialogue tab can now be closed with OK ...

Страница 30: ...in the local intranet list in order to display the web interface correctly Open Internet Explorer and navigate to the Security tab under the following path Tools Internet options Security Switch to the Local Intranet icon and click on Sites Fig 9 Then click on Advanced Fig 10 In the Add this website to the zone address line enter the device IP address and confirm with Add Default IP address http 1...

Страница 31: ...IWL3000 series 31 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen Fig 11 ...

Страница 32: ...The default configuration on delivery is User name admin Password admin Confirm your entries by clicking on OK Fig 12 Information If the login prompt does not appear check to ensure that the device has been connected via a RJ45 connection cable Otherwise connect the device to a PC Device LAN connection PC LAN connection If there is still no connection to the firewall login screen check the proxy a...

Страница 33: ...IWL3000 series 33 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen The device web interface then appears Fig 13 ...

Страница 34: ... 20 100 20 X X X 03 2 422 X 100 20 100 20 X X X 04 2 427 X 100 20 100 20 X X X 05 2 432 X 100 20 100 20 X X X 06 2 437 X 100 20 100 20 X X X 07 2 442 X 100 20 100 20 X X X 08 2 447 X 100 20 100 20 X X X 09 2 452 X 100 20 100 20 X X X 10 2 457 X 100 20 100 20 X X X 11 2 462 X 100 20 100 20 X X X 12 2 467 X 100 20 100 20 X X X 13 2 472 X 100 20 100 20 X X X Information TPC can optionally be activate...

Страница 35: ...IWL3000 series 35 ads tec GmbH Heinrich Hertz Str 1 D 72622 Nürtingen Achtung TPC is always active at 5 GHz 19 channels each 22 MHz wide ...

Страница 36: ...23 x x 52 52 5 260 60 x x 200 23 200 23 200 23 x 56 5 280 60 x x 200 23 200 23 200 23 x 60 60 5 300 60 x x 200 23 200 23 200 23 x 64 5 320 60 x x 200 23 200 23 200 23 x 100 100 5 500 60 x x 1 000 30 1 000 30 200 23 x x 104 5 520 60 x x 1 000 30 1 000 30 200 23 x x 108 108 5 540 60 x x 1 000 30 1 000 30 200 23 x x 112 5 560 60 x x 1 000 30 1 000 30 200 23 x x 116 116 5 580 60 x x 1 000 30 1 000 30 ...

Страница 37: ...nection 10 100 1000MBit s Auto crossover 1 x LAN RJ45 connection 10 100 1000MBit s Auto crossover External device dimensions 135 mm x 159 mm x 35 mm Weight approx 1 kg Protection class IP20 Max current consumption max 600 mA at 24V DC Ambient temperature during operation from 20 C to 70 during storage from 25 C to 85 C Information Detailed information about the device can be found on our website h...

Страница 38: ...tware installations please contact them as ads tec will not be able to answer such questions ads tec does not provide support services for any device that was not purchased directly from ads tec In this case maintenance and support is provided by the partner company 10 1 ads tec support The ads tec support team is available for inquiries from direct customers between 8 30am and 5 00pm Monday to Fr...

Отзывы: