General information about the gas system
Familiarise yourself with the safety instructions for handling gas.
For general safety instructions concerning the topic of "gas", see the "Safety instructions for
the gas system" (Chapter 2.5).
•
The complete gas system has been designed according to the valid technical regulations
for liquid gas equipment and burners in camping vehicles. This was examined and certified
by an expert.
•
All installed gas-operated appliances have safety devices. When the flame goes out, the
automatic flame failure device interrupts the gas supply. In spite of this safety device, the
respective quick-action stop valve must be closed if the appliance is not in operation.
Danger!
Poisoning by gas
If it smells of gas or you suspect that gas is escaping, perform the following:
Clear the danger area!
Close the shut-off valve on the gas cylinder!
Avoid ignition sources and open flames and do not smoke!
Ventilate the rooms!
Inform the camping site manager, and the fire brigade when necessary!
Warning!
Danger to life
Have repairs or modifications of the gas system performed by an authorised workshop
only!
Never modify the gas system or appliances yourself!
Never use a lighter or other open source of light at the junctions of the gas pipes to look
for leaks!
The user may make only the connection between the pressure regulator and the gas
cylinder! Any other work has to be performed by an authorised workshop!
Important!
•
The complete gas system in the vehicle is designed for an operating pressure of
30 mbar which is kept constant by the built-in pressure regulator.
•
After the expiration of two years and after the performance of modifications and repairs,
the gas system must be inspected again. Always have a gas leak test performed on this
occasion. The vehicle owner is responsible for initiating the inspection. Upon delivery of
the vehicle, the operator must be informed in writing of his/her duty to have the gas sys-
tem inspected. The correct condition of the gas system is confirmed with a gas inspec-
tion certificate. The associated gas inspection sticker must be attached to the rear of the
vehicle near the license plate.
•
The gas regulator and the gas hose must be replaced every ten years.