Advanced RF Technologies, Inc.
60
12.
APPENDIX
12.1
Shutdown Retry Logic
The function of the built-in shutdown routine is to protect the repeater from any further damage from a hard-
fail that the system may be experiencing.
Within 5 seconds of a hard-fail alarm being detected, the repeater will start the shutdown routine. The repeater
will shut down by powering off the HPAs (high-powered amplifiers) for 30 seconds.
After 30 seconds have elapsed, the repeater will power on the HPAs and check to see if the hard-fail alarm still
exists. If the hard-fail alarm still exists, then the repeater will shut down for 1 minute (double the time of the
previous shutdown time).
After 1 minute has elapsed, the repeater will power on the HPAs and check to see if the hard-fail alarm still
exists. If the hard-fail alarm still exists, then the repeater will shut down for 2 minutes (double the time of the
previous shutdown time).
The shutdown routine will repeat itself a total of 10 times. If the hard-fail alarm still exists after the 10th retry,
then the repeater will turn off its HPAs permanently until a reset is performed or factory set is executed.
Содержание PSR-VU-9537-UA
Страница 27: ...Advanced RF Technologies Inc 27 Figure 5 2 PSR ANN Repeater Mount ...
Страница 37: ...Advanced RF Technologies Inc 37 7 2 Status Tab Figure 7 3 Status Tab ...
Страница 41: ...Advanced RF Technologies Inc 41 7 3 Control Tab Figure 7 9 Control Tab ...
Страница 56: ...Advanced RF Technologies Inc 56 11 MECHANICAL DRAWING Figure 11 1 PSR VU 9537 UBMechanical Drawing ...
Страница 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Страница 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Страница 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...