Advanced RF Technologies, Inc.
18
Table 2-2
Terminal Block Definition
Silkscreen Label
Line Type
Max Supported AWG
AC_NU
Neutral
12AWG
AC_R
Line or Hot
12AWG
AC_G
Ground
12AWG
3.
OVERVIEW
3.1
LED
PSR-VU-9537-UBLED indicator lights are located on the inside of the repeater towards the bottom. Below the
LED indicators is a button that is used to trigger the door open alarm.
Figure 3-1
LED Panel
Table 3-1
LED Specifications
POWER
DL
UL
ALARM
AC Fail
DL Signal Not Detected
UL Out-Band Overload
Power-Related Alarms
DC Fail
DL Signal Low Detected
UL Input Overload
RF DL Path Related Alarms
Battery Fail
DL RF Power
UL DSP Over Input
RF UL Path Related Alarms
Low Battery
DL Out-Band Overload
UL Over Input
Over Temperature
Battery Not Charge
DL Input Overload
UL Over Power
DSP Communication
Battery Not Connected
DL DSP Over Input
UL Return Power
Door Open
Over Current
DL Over Input
UL PLL Fail
System Halt
DL Over Power
DL Return Power
DL PLL Fail
LED Indicator
Specifications
Solid Green
Normal operation
Solid Yellow
Soft Fail alarm exists in the system
Solid Red
Hard Fail alarm exists in the system
Содержание PSR-VU-9537-UA
Страница 27: ...Advanced RF Technologies Inc 27 Figure 5 2 PSR ANN Repeater Mount ...
Страница 37: ...Advanced RF Technologies Inc 37 7 2 Status Tab Figure 7 3 Status Tab ...
Страница 41: ...Advanced RF Technologies Inc 41 7 3 Control Tab Figure 7 9 Control Tab ...
Страница 56: ...Advanced RF Technologies Inc 56 11 MECHANICAL DRAWING Figure 11 1 PSR VU 9537 UBMechanical Drawing ...
Страница 57: ...Advanced RF Technologies Inc 57 Figure 11 2 PSR ANN Annunciator Mechanical Drawing ...
Страница 58: ...Advanced RF Technologies Inc 58 Figure 11 3 ADRF BBL U Mechanical Drawing ...
Страница 59: ...Advanced RF Technologies Inc 59 Figure 11 4 ADRF BBS U Mechanical Drawing ...