ADRF PSR-78-9537-XB Скачать руководство пользователя страница 1

 

Advanced RF Technologies, Inc. 

      

 

 

PSR-78-9537-XB MANUAL 

VERSION 0.24 

 

 
 

 

 

 

 

3116 West Vanowen St. 

Burbank, CA 91505 

Tel: 818-840-8131 

Fax: 818-840-8138 

www.adrftech.com

 

 

 

Содержание PSR-78-9537-XB

Страница 1: ...Advanced RF Technologies Inc i PSR 78 9537 XB MANUAL VERSION 0 24 3116 West Vanowen St Burbank CA 91505 Tel 818 840 8131 Fax 818 840 8138 www adrftech com ...

Страница 2: ...ice Advanced RF Technologies Inc 1996 2019 All rights reserved Please send comments to E Mail info adrftech com Phone 818 840 8131 800 313 9345 Fax 818 840 8138 Address Advanced RF Technologies Inc Attention Technical Publications Department 3116 Vanowen St Burbank CA 91505 USA www adrftech com ...

Страница 3: ...SION HISTORY CHANGE LIST Version Change list Contents Version Author Descriptions Date 0 1 ADRF Initial Release 08 07 2019 0 12 ADRF update 09 11 2019 0 22 ADRF B9B Update 08 04 2020 0 23 ADRF update 09 04 2020 0 24 ADRF update 22 04 2020 ...

Страница 4: ...larms 24 3 3 1 External Alarm Output interface 24 3 3 2 External Alarm Input interface 25 4 Installation 25 4 1 Installation Procedures 25 4 1 1 Wall Mount Procedure 25 4 1 2 PSR ANN Annunciator Installation 26 4 2 Antenna Separation Isolation 28 5 PSR 78 9533 X 9537 X Web GUI Setup 30 5 1 Repeater PC Connection Using Web GUI 30 5 2 Status Tab 31 5 2 1 Band Info 32 5 2 2 Power Gain 32 5 2 3 Alarms...

Страница 5: ... 5 5 4 System Update 44 5 5 5 System Backup Restore 44 5 6 Help 45 5 7 Logout 45 6 Maintenance Guide for PSR 78 9533 X 9537 X Repeater 45 6 1 Periodic Inspection Checklist 45 6 2 Preventive Measures for Optimal Operation 45 6 2 1 Recommendations 45 6 2 2 Precautions 45 7 Warranty and Repair Policy 46 7 1 General Warranty 46 7 2 Limitations of Warranty 46 7 3 Limitation of Damages 46 7 4 No Consequ...

Страница 6: ...splay Remote Power Switch Disabled 33 Figure 5 7 Status Tab AAI Alarm Display Remote Power Switch Enabled 33 Figure 5 8 Status Tab Repeater Info Repeater Location Technical Support Installer Contact Info 34 Figure 5 9 Control Tab 35 Figure 5 10 Control Tab General Setting 36 Figure 5 11 AAI Alarm Cable Alarm Input 36 Figure 5 12 Control Tab System 36 Figure 5 13 Control Tab Manual Gain Control 37 ...

Страница 7: ...4 Figure 9 3 PSR ANN Annunciator Mechanical Drawing 55 TABLES Table 1 1 Parts List 10 Table 2 1 LED Specifications 17 Table 2 2 External Alarm Port Pin Description 19 Table 3 1 Message Board Alarms and Notifications 23 Table 3 2 Alarms 23 Table 8 1 Electrical Specifications 47 Table 8 2 Mechanical Specifications 48 Table 8 3 Power Specifications 48 Table 8 4 Warranty Certificates 48 ...

Страница 8: ...d signal DAS Distributed Antenna System DL Downlink HPA High Power Amplifier HW Hardware IF Intermediate Frequency LNA Low Noise Amplifier LTE Long Term Evolution MS Mobile Station OFDM Orthogonal Frequency Division Multiplexing OFDMA Orthogonal Frequency Division Multiple Access PAR PAPR Peak to Average Power Ratio Crest Factor PLL Phase Locked Loop PSU Power Supply Unit QAM Quadrature Amplitude ...

Страница 9: ...ss public safety repeater with FirstNet support and it is fully compliant with International Fire Code IFC and National Fire Protection Association NFPA Product Features NFPA 1221 2016 code compliant and FirstNet compliant Alarming output to supervised circuits for antenna amplifier power supply battery and charger failure IP66 compliant enclosure for both indoor and outdoor environments Class B w...

Страница 10: ...bel Quantity Description A 1 PSR 78 9537 XB B 1 Wall Mount Bracket C 1 Mounting Bracket Template D 1 AAI Alarm Cable E 1 AC Power Cable F 1 Ethernet Cable Crossover G 4 Anchor Bolt H 1 PSR ANN Annunciator Panel A B C D E F G H Figure 1 1 PSR 78 9537 XB Repeater Parts List ...

Страница 11: ... Quick View Bottom AAI Alarm Port ADRF BBx Battery Port Donor Port 4 3 10 Female AC Input Port Ground Terminal Server Port 4 3 10 Female Sever CPL DL Output Monitor Port 30dB Donor CPL UL Output Monitor Port 30dB Heat Sink Air Vent Hole Annunciator Communication Power Port ...

Страница 12: ...Advanced RF Technologies Inc 12 Figure 1 3 PSR ANN Annunciator Audible Alarm Speaker Alarm Indicator Lights Data Power Port Repeater Wall Mount Bracket ...

Страница 13: ...ructure RF EXPOSURE ANTENNA PLACEMENT Guidelines Opening or tampering the PSR 78 9537 XB will void all warranties WARRANTY Lithium Battery CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO INSTRUCTIONS WARNING ELECTRIC SHOCK In accordance with the FCC regulations this device must meet 5W ERP requirements To satisfy this the antenna cable name...

Страница 14: ...d in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at their own exp...

Страница 15: ... indicated for that type are strictly prohibited for use with this device Maximum antenna gain after accounting for any cable losses should be up to DL 0 6 dBi Omni antenna UL 8 dBi Pannel antenna minimum Antenna cable length 30 m Le présent émetteur radio identifier le dispositif par son numéro de certification ou son numéro de modèle s il fait partie du matériel de catégorie I a été approuvé par...

Страница 16: ...LICENSE or express consent of an FCC Licensee to operate this device You MUST register Class B signal boosters as defined in 47 CFR 90 219 online at www fcc gov signal boosters registration Unauthorized use may result in significant forfeiture penalties including penalties in excess of 100 000 for each continuing violation Part 90 Signal Boosters This is A 90 219 CLASS B DEVICE ...

Страница 17: ...n Power DL PLL Fail LED Indicator Specifications Solid Green Normal operation Solid Yellow Soft Fail alarm exists in the system Solid Red Hard Fail alarm exists in the system 2 2 Host Remote Switch The Host Remote Switch allows the user to switch the default Repeater IP Subnet Mask and Gateway of the Ethernet port of the repeater to an alternative setup These settings can only be adjusted by loggi...

Страница 18: ...ral and ground leads The AC power is wired to a high efficiency DC switching power supply which is UL approved The AC port is located at the bottom of the repeater and has a free voltage range input of 100 240V AC Figure 2 3 AC Input Port Figure 2 4 AC On Off Switch The AC Power on off switch is on the left hand side of the PSU which is located inside of the repeater AC On Off switch ...

Страница 19: ...S Output H Orange System component malfunction_N 4 NEG Output J System Monitoring Yellow Normal AC Power_P 5 POS Output K Yellow Normal AC Power_N 5 NEG Output L Green Loss of normal AC Power_P 6 POS Output M Green Loss of normal AC Power_N 6 NEG Output N Blue Battery charger failure_P 7 POS Output P Blue Battery charger failure_N 7 NEG Output Q Purple Low battery capacity 70 _P 8 POS Output R Pur...

Страница 20: ...tem This creates a constant amplification of the same signal As a result the noise level rises above the signal level To prevent feedback the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation Isolation is attained by separating antennas a sufficient distance so that the output of one antenna does not reach the input of the other This distance is...

Страница 21: ...ttery backup unit when AC power is present Figure 2 9 Battery Switch The PSR 78 9537 XB can be connected to an ADRF BBS BBL 24 to provide power during a power failure If an ADRF BBS BBL 24 is utilized connect it to the PSR 78 9537 XB via the external battery port WARNING The circuit breaker switch on the ADRF BBS BBL 24 must be set to OFF before connecting it to the PSR 78 9537 XB to prevent damag...

Страница 22: ...and side of the BDA A grounding cable should be properly connected before powering on the equipment Figure 2 10 Ground Cable Terminal Ground terminals located on the side of the repeater and can support a ground cable up to 1 25mm 16AWG in diameter and should be permanently connected to a grounding bar ...

Страница 23: ...to the repeater Heartbeat Heartbeat is sent out to the NOC Reboot Soft reboot performed Factory setting Factory default settings restored Door Door alarm set clear 3 2 Alarms Table 3 2 Alarms Parameters Remark AC Fail The power supply is not operating within specs 4 seconds DC Fail The power supply is not operating within specs 4 seconds Temperature The module is above the normal operating tempera...

Страница 24: ...gram the repeater to either create an open or closed circuit when an alarm is present in the system 3 3 1 External Alarm Output interface Simplex Alarm Box Simplex Digital Board 24V dc ADRF PSR Repeater ADRF Digital Board External Alarm Name Set Condition Fire Alarm Donor Antenna Malfunction UL Return Power Hard Fail or No DL Signal Detected Active RF Device Malfunction RF Power Soft Fail DL Retur...

Страница 25: ...rt No External Alarm In User Alarm Remark 1 ALARM IN 1 TBD 4 INSTALLATION 4 1 Installation Procedures 4 1 1 Wall Mount Procedure Verify that the PSR 78 9537 XB and mounting holes are in good condition Place the PSR 78 9537 XB mounting bracket template up against the wall and mark off mounting holes Drill the appropriate size holes and install the included wall anchors Remove the wall mount bracket...

Страница 26: ...ured to mount to the top of the repeater with the mounting bracket at the bottom of the PSR ANN annunciator box If individually wall mounting the PSR ANN then the bracket will need to moved from the bottom of the box to the back of the box Once the PSR ANN annunciator box has securely mounted connect the included power data cable from the side of the PSR ANN box to the port labeled Annunciator on ...

Страница 27: ...Advanced RF Technologies Inc 27 Figure 4 3 PSR ANN Wall Mount ...

Страница 28: ... 4 4 RF Repeater Oscillation To prevent feedback the donor and server antennas must be separated by an appropriate distance to provide sufficient isolation Isolation can be attained by separating antennas at a sufficient distance so that the output of one antenna does not reach the input of the other This distance is dependent on the gain of the repeater Recommended isolation value is 15dB greater...

Страница 29: ...ation between the donor antenna and the serving antennas is at least 15 dB greater than the BDA gain 3 Connect the cable from the donor antenna to the BDA connector labeled DONOR and the cable from the serving antennas to the BDA connector labeled SERVER 4 Connect the AC power cord to the BDA and turn on the switch at the left of PSU 5 Installation of the BDA is now complete Adjust the gain contro...

Страница 30: ...ou are connecting to the unit remotely use of a modem then skip the step above Connect the RJ 45 crossover cable between the laptop s Ethernet port and the repeater s Ethernet port Launch either Internet Explorer or Google Chrome Type the following IP address into the address bar of the Internet Browser http 192 168 63 1 If you are connecting to the unit remotely then type the IP address of the mo...

Страница 31: ...Advanced RF Technologies Inc 31 5 2 Status Tab Figure 5 2 Status Tab ...

Страница 32: ...ays the Input Gain and Output for both downlink and uplink Figure 5 4 Status Tab Power Gain Display Input dBm Displays the in band Downlink Uplink signal level The system will display when the input level is 90 dBm Outband dBm Displays the out band composite power Gain dB o User Set Displays the amount of gain that the user set o Actual Displays the actual amount of gain that is currently in use O...

Страница 33: ... section displays the AAI alarm status for each dry contact alarm Red indicates that the dry contact alarm is active and light blue indicates the alarm is inactive If the Remote Power Switch function is enabled then the AAI Alarm In status will not be present from the AAI alarm status since this function is disabled when the Remote Power Switch is enabled Figure 5 6 Status Tab AAI Alarm Display Re...

Страница 34: ...ion Technical Support Installer Contact Info Repeater Info Displays the serial number latitude longitude firmware version and Web GUI version Repeater Location Displays the address where the repeater is installed Technical Support Displays ADRF s Technical Support contact information Installer Contact Info Displays the installer s name phone and e mail address ...

Страница 35: ...Advanced RF Technologies Inc 35 5 3 Control Tab Figure 5 9 Control Tab ...

Страница 36: ... power amplifier via our Alarm Input dry contact pins This Emergency Power Off EPO function is an optional feature that is only active when the function is enabled If the EPO function is enabled the AAI dry contact input alarm pair will no longer function This feature is available on firmware version 2 0 33 or higher and older repeaters can be updated using a field upgradeable firmware On the dry ...

Страница 37: ...he signal can be before triggering a Downlink Signal Not Detected soft fail alarm DL RF Power Level Allows the user to set a maximum deviation value for the downlink RF power before triggering a DL RF Power Level soft fail alarm For example if the input signal is 50 dBm and the gain is set to 60 dB the expected output power should be 10 dBm If the Downlink RF Power alarm value is set to 6dB then a...

Страница 38: ...Advanced RF Technologies Inc 38 5 4 Install Tab Figure 5 15 Install Tab ...

Страница 39: ... the repeater mode to either use PS700 PS800 or PS700 PS800 Figure 5 16 Install Tab Technology 5 4 2 Band Selection Figure 5 17 Install Tab Band Selection Band selection allows the user to specify the desired frequencies by inputting the center frequencies and selecting the bandwidths ...

Страница 40: ...er bandwidth Downlink Gain Minor gain adjustments can be performed on a per channel basis to equalize signal levels Downlink Freq Start Displays the start frequency of the pass band once the band selection has been set Downlink Freq End Displays the end frequency of the pass band once the band selection has been set 5 4 3 SNMP Figure 5 18 Install Tab SNMP The SNMP section allows you to specify the...

Страница 41: ...b This feature is only available if the Emergency Power Off switch function is not being utilized Figure 5 21 Install Tab AAI Input 5 4 7 Location Info Installer Info This section allows the user to specify the address of the repeater and also the information of the installer Figure 5 22 Install Tab Location Info Installer Info 5 4 8 Date Time This section allows the user to specify the current da...

Страница 42: ...istrator To delete a user account click on the Account Management link and under the Edit column click on the delete button Figure 5 24 System Account Account Management 5 5 1 2 System Account New Account The New account section allows the Administrator to create a new user account Please note that the New account section is only available if you are logged into the system as the Administrator To ...

Страница 43: ...and v3 Community strings for v1 v2c can be specified from here and SNMP user account can be created deleted from this section Figure 5 27 SNMP 5 5 3 System Logs This section displays system events that have taken place The Log displays the time and date of when the event took place and what changes were made to the system Figure 5 28 System Logs ...

Страница 44: ...e Once the firmware update is complete the following popup message will appear Figure 5 30 System Update is Complete Popup Message 5 5 5 System Backup Restore The Backup Restore section allows the user to save the settings of the repeater To perform the backup click on the Backup button and you will be prompted to save the backup file To restore the settings to the system click on Choose File butt...

Страница 45: ...Cables and connectors are in good condition Ensure that the repeater brackets are in good condition and that the repeater is securely fastened 6 2 Preventive Measures for Optimal Operation 6 2 1 Recommendations Perform the Periodic Inspection Checklist quarterly or semi annually 6 2 2 Precautions Do not operate the repeater with the antennas in extremely close proximity to one another as this may ...

Страница 46: ... liability for general consequential incidental or special damages 7 5 Additional Limitation on Warranty Advanced RF Technologies Inc standard warranty does not cover products which have been received improperly packaged altered or physically damaged For example broken warranty seal labels exhibiting tampering physically abused enclosure broken pins on connectors any modifications made without Adv...

Страница 47: ... PS 800 Filter Bandwidth Broad MHz 3 5 10 LTE 5 10 MHz Narrow KHz 6 25 12 5 25 75 200 N A Filter Roll off Broad MHz 60dBc Filter Bandwidth Edge 1MHz Narrow KHz 55dBc Filter Bandwidth Edge 3 Filter BW Spurious 3GPP Rule Compliant Passband Ripple 2 dB ALC Dynamic Range 60dB Gain Dynamic Range 45dB Channel Setting Resolution 0 025 KHz Noise Figure Max gain 5dB System Group Delay Broad Band 6us Narrow...

Страница 48: ...pecifications Table 8 3 Power Specifications Parameters Specifications Comments AC Power 100 240 VAC 60 Hz Free Voltage AC Supply Protection Fuse Circuit Protector T6 3L250V Battery Backup Power Consumption AC 150W 120V 1 25A DC 24V 6 25A Ground External Threaded Stud 8 4 Warranty Certificates Table 8 4 Warranty Certificates Parameters Specifications Comments MTBF 100 000 Hours Ambient Compliance ...

Страница 49: ...he signal from DL UDC high power level and then transmit to Triplexer 6 Server Triplexer band passes DL band signal and then transmits to Mobile Station antenna Uplink Mobile Station TRIPLEXER UDC before DSP DSP UDC After DSP HPA TRIPLEXER Base Station Figure 8 2 Uplink signal flow 1 Server Triplexer band Passes DL signal 2 UL UDC before DSP amplifies adjusts this signal received via antenna from ...

Страница 50: ... Up Down Converter Drive AMP_DL DL_800MHz DL_800 HPA Backup Battery 6 NMS 7 PSU Figure 0 1 Block Diagram FUNCTION AND SPECIFICATION PER DEVICE COMPONENT UDC Parameter Specifications DL UL RF Frequency 758 768MHz 788 798 MHz Rating Gain before DSP 57 2dB Rating Gain Gain control range after DSP 12 2dB 55 2dB 45dB 45dB 14 2dB Gain flatness p p 3dB p p 3dB VSWR Max 1 5 1 Max 1 5 1 Table 0 1 UDC speci...

Страница 51: ...Max 1 5 1 Table 0 4 DL HPA specifications UL HPA Parameter Specifications Frequency 788 798 MHz Rating Gain 35dB 1dB Gain flatness p p 3dB VSWR Max 1 5 1 Table 0 5 UL HPA specifications FREQUENCY BAND AND BLOCK This Repeater supports FirstNet it is a selective filter system You can set filter center frequency and filter bandwidth within FirstNet Simultaneous Filter Supporting 2 Wide Band LTE BW 5 ...

Страница 52: ...tion as automatic power down mechanism for protecting system from output overload The picture below is regarding output ALC function Adjustable range of ALC function is minimum 40dB ALC level do not exceed the setting power level Output Input Figure 0 1 ALC Function operation 8 MECHANICAL DRAWING ...

Страница 53: ...Advanced RF Technologies Inc 53 Figure 8 1 PSR 78 9537 XB Mechanical Drawing ...

Страница 54: ...Advanced RF Technologies Inc 54 Figure 8 2 PSR 78 9537 XB Mechanical Drawing ...

Страница 55: ...Advanced RF Technologies Inc 55 Figure 8 3 PSR ANN Annunciator Mechanical Drawing ...

Страница 56: ... on the HPAs and check to see if the hard fail alarm still exists If the hard fail alarm still exists then the repeater will shut down for 1 minute double the time of the previous shutdown time After 1 minute has elapsed the repeater will power on the HPAs and check to see if the hard fail alarm still exists If the hard fail alarm still exists then the repeater will shut down for 2 minutes double ...

Отзывы: