RK3000 High Frequency Power Supply
Operating Manual
Page 40 of 73
selection will appear opposite the word Enter, and become active when the ENTER key is
pressed.
If the present operating mode is acceptable, simply press ENTER without making any
changes. Either way, the display will now change to the Alarm 4 Trip Parameter Screen.
To trip the control for an external alarm condition on the Alarm 4 input, press the 1 key.
To just alarm for an external alarm condition on the Alarm 4 input, press the 0 key. Your
selection will appear opposite the word Enter, and become active when the ENTER key is
pressed.
If the present operating mode is acceptable, simply press ENTER without making any
changes. Either way, the display will now change to the External Alarm Trip Prompt
Screen.
Press the DOWN or UP keys to view more prompt screens or press ESC to return the
display to either the Electrical Reading Screen or the Device Status Screen depending on
the screen you were in prior to pressing the PROMPT key.
External Alarm Message Text
Press the PROMPT key and then the DOWN
key until the “External Alarm Message Text”
Prompt Screen appears.
Press ENTER and the ‘External Alarm Message Text” Parameter Screen will appear.
Press ENTER, and a list of the first four alarm texts that could appear in the Device
Status Screen if any of the Alarms 1 through 4 are active, will show. Pressing ENTER
again will bring up the next four alarm texts. Keep pressing ENTER until all alarm texts
have been viewed. Note the number of the text you would like to appear.
See Appendix III for a list of the texts.
When all alarm texts have been viewed, the External Alarm 1 Text Parameter Screen will
appear.
The second line in the display shows the present text for this alarm input.
RED-01
External Alarm 4
0=Nontrip, 1=Trip
Enter: 1
RED-01
External Alarm Msg Text
RED-01
Use the ENTER key to
view the available
alarm messages
Ext. Alarm 1 Text
External Alarm 1
Range: 1-14
Enter: 01