RK3000 High Frequency Power Supply
Operating Manual
Page 31 of 73
Programming
“Prompt Key” Parameters
PROMPT Key
The functions not found on the discrete keys are programmed through
the use of the PROMPT key. Pressing the PROMPT key brings up the
first of twenty (20) prompts of additional programmable parameters.
Pressing the UP and DOWN keys scrolls the display forward and
backwards through the prompt displays.
The following programmable parameters appear sequentially when
pressing the PROMPT key and then the DOWN key.
Averaged Readings
Pre-spark Readings
Conduction Display
Spark Rate Control
Quench Mode
Process Sense
Peak Limits
Software Version
Reinitialize Keypad and Display Unit
Reinitialize Interface Unit
Max. Set Size
External Alarm trip
External Alarm Message Text
Under Voltage Setup
Energy Management set-up
Wash Down System
Power Down Rapping
Rapper System Set-up
If you are in a prompt screen, and return to the Electrical Reading Screen or the Device
Status Screen, when you press the PROMPT key again you will be returned to the last
prompt that was displayed. If the security code times out before returning to the
PROMPT key, the prompts will start with the Averaged Readings prompt.
The following are instructions on programming all the parameters found under the
PROMPT key. They are listed in the order found by pressing the down arrow.
Average Readings
Press the PROMPT key and the “Averaged Readings” prompt screen appears.
Press ENTER and the ‘Averaged Readings’ parameter screen will appear).
This screen allows the Averaged Readings display to be enabled (1) or disabled (0). If
the Averaged Reading is enabled, the “normal” display will show electrical readings that
RED-01
Averaged Reading
RED-01
Averaged Reading
0=Disable, 1=Enable
Enter: 0