
Function Block and Operation Theory
39
4.6.4
Delay-trigger Acquisition
Use delay-trigger acquisition to delay the data collection after the
trigger event, as illustrated in Figure 4-14. The delay time is speci-
fied by a 32-bit counter value so that the maximum delay time is
the period of TIMEBASE X (232 - 1), while the minimum delay is
the period of timebase.
Figure 4-14: Delay-trigger Mode Operation
Time
Operation start
Trigger
Data
Trigger Event
Occurs
Acquisition stop
Begin to transfer data to system
N samples
Acquisition start
Delay Time