Signal Connection
49
PCI-8254 / PCI-8258
3.4 Emergency Stop Input
PCI-8254/PCI-8258 provides one hardware input emergency stop
signal (EMG). If the external emergency stop signal is triggered, all
motion control commands will be stopped immediately. In addition, the
DIN-825-GP4 is designed to transmit external emergency stop signal
to servo/stepper motor drive to stop operation of every motor
immediately. See below for corresponding pins of emergency stop
signal input on DIN-825-GP4:
• Signal connection diagram:
Figure 3-5: Emergency stop signal connection example
J5 Pin No
Signal Name
Description
Axis #
5
EEMG
External emergency stop input
(external input)
-
CMPx / CMAx
Pin No (x=1~4)
Signal Name
(n=1~8)
Description
Axis #
19
EMG(n)
Emergency stop (output to drive)
1~8
NOTE
NOTE
PCI-8258 need two DIN-825-GP4 for eight axes motion control
functions
# 1 controls axes 1 ~ 4 and #2 controls axes 5 ~ 8
PCI-8254/PCI-8258
CMPx /
CMAx
x=1~4
J5
P1
DICOM
IEMG
EEMG
EMG
PS2805
DGND
Servo Drive
DIN-825-GP4
Содержание PCI-8254
Страница 2: ...ii Revision History Revision Date Description 2 00 2014 08 13 First release ...
Страница 8: ...viii Table of Contents Important Safety Instructions 209 Getting Service 211 ...
Страница 12: ...xii List of Figures ...
Страница 14: ...xiv List of Tables ...
Страница 24: ...10 Introduction ...
Страница 54: ...40 Getting Start with The Installation ...
Страница 78: ...64 Signal Connection ...
Страница 111: ...Motion Control Theory 97 PCI 8254 PCI 8258 MCP2 Bode plot page ...
Страница 165: ...Motion Control Theory 151 PCI 8254 PCI 8258 Example Figure 4 55 Continuous interpolation examples ...
Страница 222: ...208 Motion Control Theory ...