background image

Leading

EDGE COMPUTING

NEON-2000-JT2-X Series

AI Smart Camera

User’s Manual

Manual Rev.: 

1.0

Revision Date: 

October 27, 2020

Part No: 

50-1Z338-1000

Содержание NEON-2000-JT2-X Series

Страница 1: ...Leading EDGE COMPUTING NEON 2000 JT2 X Series AI Smart Camera User s Manual Manual Rev 1 0 Revision Date October 27 2020 Part No 50 1Z338 1000 ...

Страница 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Changes 1 0 2020 10 27 Initial version ...

Страница 3: ...n even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsibility to global environmental preservation through compliance with the Euro pean Union s Restriction of Hazardous Substances RoHS direc tive and Waste Electrical and Electronic Equipment WEEE directive Environmental protection is a top priority for ADLINK We have enf...

Страница 4: ... trying to com plete a task ATTENTION Informations destinées à prévenir les blessures corporelles mineures les dommages aux composants la perte de données et ou la corruption de programme lors de l exécu tion d une tâche WARNING Information to prevent serious physical injury component damage data loss and or program corruption when trying to complete a specific task AVERTISSEMENT Informations dest...

Страница 5: ...Accessories 6 2 Connectors and I O 7 2 1 Bottom Side I O and Connector Description 8 2 1 1 DI O Connector Pin Definitions 9 2 1 2 LAN Connector Pin Definitions 11 2 2 Top Side LED Indicators 12 2 3 Front Side Description 13 3 Getting Started 15 3 1 Mounting the Device 15 3 1 1 DIN Rail Mount 16 3 2 Digital I O Connections 17 3 3 Attaching a Lens 18 3 4 Power and Peripheral Connections 19 3 5 Image...

Страница 6: ...n Utility 26 3 6 1 Capturing Images in pylon 26 3 6 2 Modifying Image Sensor Settings in pylon 29 3 6 3 Using APIs to Modify Image Sensor Settings 33 4 Software Upgrade 35 4 1 System Flash 35 4 1 1 System Flashing Equipment 36 4 1 2 System Flashing Procedure 37 Important Safety Instructions 39 Consignes de Sécurité Importante 41 Getting Service 43 ...

Страница 7: ...e 2 5 Top Side LED Indicators 12 Figure 2 6 Front Side Components 13 Figure 3 1 NEON 2000 JT2 X Mounting Holes 15 Figure 3 2 DIN Rail Mount Separated 16 Figure 3 3 DIN Rail Mount Assembled 16 Figure 3 4 Digital Input Schematic Diagram 17 Figure 3 5 Digital Output Schematic Diagram 17 Figure 3 6 Lens Attachment Assembly 18 Figure 3 7 Powered by AC DC Adapter 19 Figure 3 8 Powered by USB Type C Hub ...

Страница 8: ...viii List of Figures Leading EDGE COMPUTING This page is intentionally left blank ...

Страница 9: ...e 1 2 NEON 2000 JT2 X Starter Kit Contents 6 Table 2 1 Bottom Side Connectors and Functions 8 Table 2 2 DI O M12 17 Pin Connector Pin Definitions 10 Table 2 3 DI O Connector Specifications 10 Table 2 4 LAN Connector Pin Definitions 11 Table 2 5 Top Side LED Indicator Behavior 12 Table 2 6 Front Side Description 13 ...

Страница 10: ...x List of Tables Leading EDGE COMPUTING This page is intentionally left blank ...

Страница 11: ...vers and utilities are pre installed to save effort on integration and prevent compati bility issues The following table lists the current NEON 2000 JT2 X models and their respective sensor specifications Table 1 1 NEON 2000 JT2 X Model and Sensor Specifications Model Name Image Sensor Specifications Image Sensor Module NEON 201B JT2 X 1 3 1 2M Global Shutter 1280x960 54fps Color Basler DAA1280 54...

Страница 12: ...X2 and dual core NVIDIA Denver 2 quad core ARM Cortex A57 8GB 128 bit LPDDR4 memory and integrated 256 core Pascal GPU USB 3 0 sensor interface compatible with most machine vision software IP67 USB Type C connector supports DC power and Dis playPort to reduce cabling IP67 M12 17 pin connector for DC 24V input DI O and RS 232 IP67 M12 8 pin connector for Gigabit Ethernet Highly integrated compact s...

Страница 13: ...DDR4 Storage 32 GB eMMC on Jetson TX2 module Camera connectors and functions 1x IP67 USB Type C for power DisplayPort and USB 3 0 1x IP67 M12 17 pin connector for DC 24V input RS 232 and DI O 1x IP67 M12 8 pin connector for Gigabit Ethernet NOTE NOTE 1 When powering from the DC 24V input the USB Type C connector can provide 3W of power to an external device such as a USB Type C hub Devices that re...

Страница 14: ...or Size 1 3 1 1 8 1 3 7 1 2 5 Frame Rate fps 54 60 30 14 Shutter Global Rolling Color Mono Color Image Sensor Trigger Mode External trigger see note below software trigger free run Digital Input 2x DI includes 1x sensor trigger Digital Output 2x DO includes 1x strobe out RS 232 TXD RXD GND Dimensions Weight 123 x 122 85 x 79 55mm 900g Power Supply DC power over USB Type C or DC 24V over M12 17 pin...

Страница 15: ...Introduction 5 NEON 2000 JT2 X 1 4 Mechanical Dimensions This section provides dimensions and related mechanical informa tion for the NEON 2000 JT2 X 1 4 1 Camera Dimensions Dimensions mm ...

Страница 16: ...wer Display Port and USB 3 0 30 01335 0000 A0 IP67 Ethernet cable M12 A code 8P M to RJ45 M 3m Supports Gigabit Ethernet 30 01336 0000 A0 IP67 DI O cable M12 A code 17P M to DB37P M 3m Supports DC24V 2x DI O and 1x RS 232 NEON side 17P other side 37P to DIN 37 01 30 01337 0000 A0 Flash cable M12 A code 17P M to USB 2 0 Type A M SWx2 For flashing the Jetson TX2 30 01338 0000 A0 DIN 37D 01 terminal ...

Страница 17: ... JT2 X 2 Connectors and I O This chapter includes the locations and descriptions of the connectors and I O on the NEON 2000 JT2 X Figure 2 1 NEON 2000 JT2 X Orientation Top Side Top Side Bottom Side Bottom Side Front Side Back Side ...

Страница 18: ...e 2 1 Bottom Side Connectors and Functions Item Description 1 IP67 USB Type C connector for power DisplayPort and USB 3 0 2 IP67 M12 17 pin connector for DC 24V input 2x DI O and 1x RS 232 3 IP67 M12 8 pin connector for Gigabit Ethernet NOTE NOTE DC power can be supplied from either the USB Type C port or the M12 17 pin connector 1 2 3 ...

Страница 19: ...2 0 D for flashing the TX2 2 Input DC 24V input 3 Input DC 24V input 4 Input Digital input 0 Trigger input 0 see Note 1 5 Output Digital output 0 Strobe output 0 see Note 2 6 Output Digital output 1 7 Reserved 8 Reserved 9 Input TX2 recovery for flashing the TX2 10 Bi DIR USB 2 0 D for flashing the TX2 11 Input USB 2 0 power for flashing the TX2 ...

Страница 20: ... and set the camera to hardware trigger mode to enable real time or hardware triggered image capture 2 Pin 5 Digital output 0 Strobe output 0 is programmable When configured for strobe output pin 5 can be connected to an LED strobe controller to adjust the timing latency delay according to the camera connected to pin 5 I O Category Maximum Throughput Specifications RS 232 Baud rate 9600bps 8N1 Dig...

Страница 21: ...ectors and I O 11 NEON 2000 JT2 X 2 1 2 LAN Connector Pin Definitions Figure 2 4 LAN Connector Table 2 4 LAN Connector Pin Definitions Pin Description 1 MDI2 2 MDI3 3 MDI3 4 MDI0 5 MDI1 6 MDI0 7 MDI2 8 MDI1 ...

Страница 22: ...rs Table 2 5 Top Side LED Indicator Behavior LED Function Description LAN Ethernet status indicator Red Ethernet is active Green 100 1000 Mbps Orange Red Green Ethernet is working normally POWER STATUS System and power indicator Red System is ready Green Power on Orange Red Green Camera is working normally ...

Страница 23: ...N 2000 JT2 X 2 3 Front Side Description Figure 2 6 Front Side Components Table 2 6 Front Side Description Item Description 1 C mount type lens mount 2 Image sensor 3 Lens protector mounting thread Metric thread M60x1 5mm 3 1 2 ...

Страница 24: ...14 Connectors and I O Leading EDGE COMPUTING This page is intentionally left blank ...

Страница 25: ...evice The NEON 2000 JT2 X can be mounted using the mounting screw holes on either the front A or back B sides Le NEON 2000 JT2 peut être monté à l aide des trous de vis de montage sur les côtés avant A ou arrière B Figure 3 1 NEON 2000 JT2 X Mounting Holes A A A A B B B B ...

Страница 26: ...g Started Leading EDGE COMPUTING 3 1 1 DIN Rail Mount You can purchase a DIN rail kit and related accessories from ADLINK P N 91 95281 000E Figure 3 2 DIN Rail Mount Separated Figure 3 3 DIN Rail Mount Assembled ...

Страница 27: ...devices such as trigger sensors LED light controllers and relays can be connected to the NEON 2000 JT2 X to implement different applications This section shows how to connect such devices Figure 3 4 Digital Input Schematic Diagram Figure 3 5 Digital Output Schematic Diagram ...

Страница 28: ...ng EDGE COMPUTING 3 3 Attaching a Lens The NEON 2000 JT2 X is compatible with C mount type lenses Figure 3 6 Lens Attachment Assembly NOTE NOTE The transfer ring is preinstalled The washer is used only with the NEON 202B JT2 X ...

Страница 29: ...lowing figures show examples of power and peripheral con nection configurations Figure 3 7 Powered by AC DC Adapter NOTE NOTE This configuration requires an ADLINK AC DC power adapter P N 31 62138 0000 and I O extension board DIN 37 01 P N 91 14025 1020 Do not supply power to the camera from the AC DC adapter and the USB Type C hub adapter at the same time DIN 37 01 AC DC Adapter AC Power RS 232 D...

Страница 30: ...uration requires an ADLINK USB Type C hub adapter P N 92 99090 1010 Do not supply power to the camera from the AC DC adapter and the USB Type C hub adapter at the same time DIN 37 01 RS 232 Devices External I O Devices USB Type C Hub Adapter AC Power HDMI Monitor USB Keyboard Mouse DI O Cable USB Type C Cable ...

Страница 31: ...ecute the classification sample code with the NEON 2000 JT2 X 3 5 1 Executing the Sample Code 1 Right click the Capture_and_inference_Sample folder on the desktop and select Open in Terminal 2 Enter and execute the following command build aarch64 bin imagenet camera Sensor_width Sensor_height Sensor_width and Sensor_height are based on the camera model and sensor settings For example for the NEON ...

Страница 32: ...22 Getting Started Leading EDGE COMPUTING build aarch64 bin imagenet camera 1920 1080 Image capture and inference results will appear in a new window with the inference result in the upper left corner ...

Страница 33: ...Getting Started 23 NEON 2000 JT2 X You can also modify the Sensor_width and Sensor_height settings in the pylon Viewer utility For details see Modifying Image Sensor Settings in pylon ...

Страница 34: ...networks Sample code Capture_and_Inference_Sample examples imagenet cam era imagenet camera cpp Capturing images Capture_and_Inference_Sample utils camera indCam era cpp Execution file Capture_and_Inference_Sample build aarch64 bin ima genet camera To learn more about image sensors samples and documents are included in opt pylon5 For more samples relating to image infer ence NVIDIA provides exampl...

Страница 35: ...Format Control Pixel Format RGB8 4 Classify the image The image source can be defined as either from the NEON 2000 JT2 X or storage media The following commands will result in errors if the NEON 2000 JT2 X sensor is still connected to pylon Viewer If an error occurs disconnect the camera by clicking Close Camera in pylon Viewer build aarch64 bin imagenet camera input_width input_height build aarch...

Страница 36: ...s 3 6 1 Capturing Images in pylon The following steps illustrate how to capture images using the Basler pylon Viewer application 1 Click the pylon Viewer icon 2 Select the sensor name and click the Open Camera but ton to open the camera NOTE NOTE Basler daA1920 30ucADL is the image sensor for the NEON 203B JT2 X and NEON 204B JT2 X The sensor name that appears will reflect the model being used ...

Страница 37: ...Getting Started 27 NEON 2000 JT2 X 3 Click the Single Shot or Continuous Shot button to capture images Single Shot Continuous Shot ...

Страница 38: ...28 Getting Started Leading EDGE COMPUTING The camera will capture images and display activity according to the selected option Single Shot Continuous Shot ...

Страница 39: ...ications This section illustrates how to modify image sensor settings in the Basler pylon utility 1 Click the pylon Viewer icon 2 Select the sensor name and click the Open Camera but ton to open the camera NOTE NOTE Basler daA1920 30ucADL is the image sensor for the NEON 203B JT2 X and NEON 204B JT2 X The sensor name that appears will reflect the model being used ...

Страница 40: ...30 Getting Started Leading EDGE COMPUTING 3 Click Camera Load Features 4 Select the desired pfs file and click Open to load the sensor settings ...

Страница 41: ...Getting Started 31 NEON 2000 JT2 X The image sensor settings will update and appear under Features in the main window 5 Modify the image sensor settings as needed 6 Click Camera Save Features ...

Страница 42: ...32 Getting Started Leading EDGE COMPUTING 7 Select a location specify a name for the pfs file and click Save to save the sensor settings ...

Страница 43: ...ettings After opening the device you can add the PylonFeaturePersis tenceLoad function to load features and modify the image sensor settings You can find supporting documentation and additional sample code in the following directories opt pylon5 share doc C opt pylon5 Samples C ...

Страница 44: ...34 Getting Started Leading EDGE COMPUTING This page is intentionally left blank ...

Страница 45: ...edule Important Notice NVIDIA official operating system releases for the Jetson TX2 development kit CANNOT be used on the NEON 2000 JT2 X Be sure to upgrade the NEON 2000 JT2 X with an operating system or flash file ONLY from ADLINK DO NOT use the NVIDIA SDK manager to upgrade the NEON 2000 JT2 X 4 1 System Flash This section describes the equipment and procedures required to flash the NEON 2000 J...

Страница 46: ...e following table lists the required tools for flashing the NEON 2000 JT2 X OS image Item Description Note 1 1x Host PC Minimum requirements Intel Core i3 CPU 4 GB DDR and 128 GB of free SSD HDD space Ubuntu Desktop 16 04 or 18 04 3 System Flash Cable ADLINK P N 30 01338 0000 A0 ...

Страница 47: ...put on the bottom side of the NEON 2000 JT2 X 2 Power on the NEON 2000 JT2 X and wait for the status LED to solid light orange not flashing 3 Connect the NEON 2000 JT2 X to the host PC using the system flash cable 4 Enter Recovery Mode using the system flash cable 5 Press and hold the black button for at least three sec onds 6 With the black button depressed press the red button and then release t...

Страница 48: ...r_Tegra NEON 32 2_20190828 bootloader sudo multi_tegra_flash sh The system flash process is now started The flash process takes about twelve minutes to complete NOTE NOTE The names of the directory and flash file in this example are for illustration only Directory and flash file names will vary accord ing to your system configuration and the specific flash file used ...

Страница 49: ...s required for user ser vicing Turn off power and unplug any power cords cables Reinstall all chassis covers before restoring power To avoid electrical shock and or damage to device Keep device away from water or liquid sources Keep device away from high heat or humidity Keep device properly ventilated do not block or cover ventilation openings Always use recommended voltage and power source setti...

Страница 50: ... starting the system up It is recommended that the device be installed only in a server room or computer room where access is Restricted to qualified service personnel or users familiar with restrictions applied to the location reasons therefor and any precautions required Only afforded by the use of a tool or lock and key or other means of security and controlled by the authority responsible for ...

Страница 51: ...ion et débranchez tous les cordons câbles d alimentation Réinstallez tous les couvercles de châssis avant de rétablir l alimentation Pour éviter les chocs électriques et ou les dommages à l appareil Gardez l appareil éloigné de l eau ou des sources de liquide Gardez l appareil loin de la chaleur ou de l humidité élevée Gardez l appareil correctement ventilé ne bloquez pas et ne couvrez pas les ouv...

Страница 52: ...es avec un tournevis avant de démarrer le système Il est recommandé d installer l appareil uniquement dans une salle de serveurs ou une salle informatique où l accès est Réservé au personnel de service qualifié ou aux utilisateurs familiers avec les restrictions appliquées à l emplacement les raisons de celles ci et les précautions nécessaires Seulement permis par l utilisation d un outil ou d une...

Страница 53: ... 1 408 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China Tel 86 21 5132 8988 Fax 86 21 5132 3588 Email market adlinktech com ADLINK Technology GmbH Hans Thoma Strasse 11 D 68163 Mannheim Germany Tel 49 621 43214 0 Fax 49 621 43214 30 Email emea adlinkt...