ADLINK Technology MVP-5100 Скачать руководство пользователя страница 31

System Layout

 21

MVP-5100

3.1.12

COM Port Connectors

The MVP-5100 provides four COM ports through D-sub 9-pin con-
nectors. The COM1 & COM2 ports support RS-232/422/485
modes by BIOS setting, while COM3 and COM4 support only RS-
232.

Figure 3-10: COM Port Pin Definition

Table  3-11: D-Sub 9-pin Signal Function of COM Ports

Pin

Signal Name

RS-232

RS-422

RS-485

1

DCD#

TXD422-

485DATA-

2

RXD

3

TXD

N/S

4

DTR#

RXD422-

N/S

5

GND

N/S

N/S

6

DSR#

N/S

N/S

7

RTS#

N/S

N/S

8

CTS#

N/S

N/S

9

RI#

N/S

N/S

1

5

6

9

Содержание MVP-5100

Страница 1: ...NG MVP 5100 Series Value Line 9th Gen Intel Core i7 i5 i3 8th Gen Celeron Processor Embedded Fanless Computer MVP 510A 5101 5102 5103 5104 User s Manual Manual Rev 1 0 Revision Date February 20 2020 P...

Страница 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 2020 02 20 Initial release...

Страница 3: ...of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social responsi bility to...

Страница 4: ...eir respective companies Conventions Take note of the following conventions used throughout this manual to make sure that users perform certain tasks and instructions properly NOTE NOTE Additional inf...

Страница 5: ...es 2 2 Specifications 3 2 1 MVP 510A MVP 5101 3 2 2 MVP 5102 MVP 5103 MVP 5104 5 2 3 MVP 5100 Functional Block Diagram 7 2 4 Display Options 8 2 5 Mechanical Dimensions 9 3 System Layout 11 3 1 Front...

Страница 6: ...Chipset 55 B 4 Security 66 B 5 Boot 68 B 6 Save Exit 70 C Appendix Watchdog Timer WDT Function Library 73 C 1 WDT with API Windows 73 C 2 WDT with DOS Linux 76 D Appendix Digital Input Output Functio...

Страница 7: ...16 Table 3 6 VGA Connector Pin Definition 17 Table 3 7 Ethernet Port Pin Definition 19 Table 3 8 Active Link LED Indicators 19 Table 3 9 Speed LED Indicators 19 Table 3 10 DC Power Input Pin Definiti...

Страница 8: ...viii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Страница 9: ...ector Pin Definition 14 Figure 3 4 Digital Input Circuit 15 Figure 3 5 Digital Output Circuit 15 Figure 3 6 DVI D Connector Pin Definition 16 Figure 3 7 VGA Connector Pin Definition 17 Figure 3 8 Ethe...

Страница 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Страница 11: ...ant and noise challenges presented by harsh IA environments the elimination of problematic structural elements that negatively affect MTBF greatly increases lifecycle expecta tions for the platform 1...

Страница 12: ...etain the shipping carton and packing mate rials for inspection Obtain authorization from your dealer before returning any product to ADLINK Ensure that the following items are included in the package...

Страница 13: ...AT i219 supports Intel AMT vPro w C246 Serial Ports COM1 2 RS 232 422 485 COM3 4 RS 232 Optional COM5 6 RS 232 shared w DI O DI O 8 ch DI and 8 ch DO USB 3x USB 3 1 Gen 1 3x USB 2 0 1x internal USB 2...

Страница 14: ...airflow 0 6 m s w industrial storage 20 C to 60 C w airflow 0 6 m s w industrial storage Storage Temperature 40 C to 85 C excluding storage devices Humidity approx 95 40 C non condensing Vibration Ope...

Страница 15: ...3x Intel GbE 2x i211AT i219 supports Intel AMT vPro w C246 Serial Ports COM1 2 RS 232 422 485 COM3 4 RS 232 Optional COM5 6 RS 232 shared w DI O DI O 8 ch DI and 8 ch DO USB 3x USB 3 1 Gen 1 3x USB 2...

Страница 16: ...ature 20 C to 60 C w airflow 0 6 m s w industrial storage Storage Temperature 40 C to 85 C excluding storage devices Humidity approx 95 40 C non condensing Vibration Operating 5 Grms 5 500 Hz 3 axes w...

Страница 17: ...CN PCIe Intel LAN I211 RJ45 CN PCIe Intel LAN I211 RJ45 CN M 2 CN 2280 3042 size PCIe x1 or SATA USB 2 USB 3 for H310 PCIe x2 or SATA USB 2 USB 3 for C246 Mini PCIe full size PCIe x1 and USB 2 0 CFast...

Страница 18: ...s the MVP 5100 controller can support two H310 or three C246 independent displays with configurations as follows Table 2 1 Maximum Available Resolution Display Configurations Port Resolution Display O...

Страница 19: ...Specifications 9 MVP 5100 2 5 Mechanical Dimensions Figure 2 2 MVP 5100 Top View including wall mount brackets units mm 225 238 239 186 240 210 226 A 20 R2 6 R5 5 2 7 2 20...

Страница 20: ...10 Specifications Leading EDGE COMPUTING Figure 2 3 MVP 5100 Side View including wall mount brackets Figure 2 4 MVP 5100 Front View including wall mount brackets units mm 240 88 units mm 86 210 88...

Страница 21: ...e 3 1 Front Panel I O Table 3 1 Front Panel I O Legend A DC Power Input I Extend Power Button B DisplayPort x2 J Power C DVI D K Reset D VGA L Audio Mic Phones Speaker E USB 2 0 Type A x3 1 2 4 M Digi...

Страница 22: ...front panel indicate the following 3 1 3 Reset Button The reset button executes a hard reset for the MVP 5100 LED Indicator Color Description Watchdog WD Yellow Indicates watchdog timer status When wa...

Страница 23: ...rt Pin Definition Table 3 3 Applicable Cable Types Pin Signal Pin Signal 1 CN_DDPx0 11 GND 2 GND 12 CN_DDPx3 3 CN_DDPx0 13 CN_DDPx_AUX_SEL 4 CN_DDPx1 14 CN_DDPx_CONFIG2 5 GND 15 CN_DDPx_AUX 6 CN_DDPx1...

Страница 24: ...t X Output type Open drain N channel X MOSFET driver with internal pull high of 200 resistance X Source Sink current for all channels 24mA X VOH 2 4 to 5V X VOL 0 to 0 5V Figure 3 3 Digital I O Connec...

Страница 25: ...System Layout 15 MVP 5100 Figure 3 4 Digital Input Circuit Figure 3 5 Digital Output Circuit D G N N S 2 2 N D G S 200 2 2...

Страница 26: ...3 6 DVI D Connector Pin Definition Table 3 5 DVI D Connector Pin Definition Pin Signal Pin Signal Pin Signal 1 DVIdata 2 10 DVIdata 1 19 GND 2 DVIdata 2 11 GND 20 N C 3 GND 12 N C 21 N C 4 N C 13 N C...

Страница 27: ...Figure 3 7 VGA Connector Pin Definition Table 3 6 VGA Connector Pin Definition Pin Signal 1 G_VGA_R 2 G_VGA_G 3 G_VGA_B 4 N C 5 GND 6 GND 7 GND 8 GND 9 N C 10 GND 11 N C 12 CRT_DDAT_CN 13 G_VGA_HSYNC...

Страница 28: ...connection on the front panel All USB 3 1 ports are compatible with SuperSpeed Gen2 high speed full speed and low speed USB devices The H310 SKU supports three USB 3 1 Gen1 ports only 3 1 10 Gigabit...

Страница 29: ...e Link Yellow Pin 10BASE T 100BASE TX 1000BASE T 1 TX LAN_TX0 2 TX LAN_TX0 3 RX LAN_TX1 4 LAN_TX2 5 LAN_TX2 6 RX LAN_TX1 7 LAN_TX3 8 LAN_TX3 LED Color Status Description Yellow OFF Ethernet port is di...

Страница 30: ...up to 2000 m where output meets LPS and SELV circuit requirements Power Source Rating Pin Signal 1 V DC_IN 2 V DGND Voltage Current DC Power Source 12 to 24VDC 12A to 6A min AC to DC Adapter 24VDC 6...

Страница 31: ...232 422 485 modes by BIOS setting while COM3 and COM4 support only RS 232 Figure 3 10 COM Port Pin Definition Table 3 11 D Sub 9 pin Signal Function of COM Ports Pin Signal Name RS 232 RS 422 RS 485...

Страница 32: ...300MB s are supported The host SATA controller provides a legacy operating mode using I O space and an AHCI operating mode using memory space The CFast card can func tion as a storage device for syste...

Страница 33: ...System Layout 23 MVP 5100 3 2 Internal I O Connectors 3 2 1 Mainboard Connector Locations Figure 3 12 Mainboard Connectors A B C D E F G H I J K L M N O P Q R S T U V W...

Страница 34: ...SIM for Mini PCIe K Mini PCIe L Wafer for I2C sensor M Wafer for Speaker N Wafer for COM x2 optional DI x8 DO x8 Mic in and Line Out O Wafer for COM x4 P Wafer for I2C sensor Q Internal Power button R...

Страница 35: ...ule Power Header Pin Definition 3 2 3 USB 2 0 Connector One USB 2 0 Type A connector is provided on the mainboard for internal USB dongle with another on the backplane board 3 2 4 Mini PCIe Connector...

Страница 36: ...2V Fan Connector Pin Definition 3 2 7 Clear CMOS Jumper Upon encountering an abnormal condition preventing the device from booting the jumper can clear the BIOS content stored in CMOS and restore defa...

Страница 37: ...RESET Header An internal header is provided for the Power and Reset buttons with pin definition as shown Figure 3 16 PWR RESET Header Pin Definition Table 3 15 PWR RESET Header Pin Definition Pin Sig...

Страница 38: ...rier Board One 12V power pin header provides additional AFM MXM carrier board power for an MXM card if used Figure 3 17 12V Power Pin Definition Table 3 16 12V Power Pin Definition Pin Signal Pin Sign...

Страница 39: ...Input on page 20 to the inputs of the DC power connector making sure to use the correct input voltage andpolarity WARNING Before providing DC power ensure the voltage and polarity pro vided are compa...

Страница 40: ...uded in the Accessory Box to attach the 2 included wall mount brackets to the chassis as indi cated by the red circles below Utilisez les 6 vis M4 6 mm incluses dans la bo te d accessoires pour fixer...

Страница 41: ...ording to the spacing dimensions of the holes in the bracket as shown in Figure 2 2 MVP 5100 Top View including wall mount brackets Montez l appareil sur un mur l aide des 4 ouvertures de trou de serr...

Страница 42: ...10 drivers for your system from the prod uct page at https www adlinktech com Products Industrial_PCs_ Fanless_Embedded_PCs ExpandableFanlessEmbedded Computers MVP 5100_Series and install The followi...

Страница 43: ...opback and an internal hard disk driver is installed Information is presented for reference only Actual power con sumption will vary with different attached devices and operating system Table A 1 Powe...

Страница 44: ...m is required to meet these specifications At least 100W at 24V input is recommended X Heat generated by add on PCI PCIe adapters affects thermal stability Additional heat dissipa tion is required whe...

Страница 45: ...ships with default settings that work well for most configurations Enter BIOS setup by selecting DEL when the system is powered on the POST Power On Self Test message is displayed The MVP 5100 control...

Страница 46: ...rsion System Information Shows current system Project Name CPU Board Version CPU Branding String CPU Stepping GT Info CPU Frequency Total Memory Memory Frequency PCH SKU and Stepping WARNING Changing...

Страница 47: ...Time or System Date using the up and down Arrow keys 2 Enter new values using the keyboard and select Enter 3 Select Tab to move between fields NOTE NOTE The date must be entered in MM DD YY format an...

Страница 48: ...38 BIOS Setup Leading EDGE COMPUTING B 2 Advanced Accesses advanced options of the MVP 5100 CAUTION Setting incorrect or conflicting values in Advanced BIOS Setup may cause system malfunction...

Страница 49: ...ed for Hyper Threading Technology When Disabled only one thread per enabled core is enabled Active Processor Cores Number of cores to enable in each processor package Intel VMX Virtualization Technolo...

Страница 50: ...e controlled P states TCC Activation Offset Offset from factory set TCC activation temperature at which the Thermal Control Circuit must be activated TCC will be activated at TCC Activation Temp TCC A...

Страница 51: ...ystem to wake on the hr min sec specified DynamicTime sets system to wake ay the current time Increase minute s Ring Wake Enables disables RI ping for Wake On Ring function PCH PME signal PCIe Wake En...

Страница 52: ...bles disables SIO COM1 Console Redirection Console Redirection Settings Specify how the host computer and the remote computer in use exchange data Both computers should have the same or compat ible se...

Страница 53: ...ta Both computers should have the same or compat ible settings B 2 4 USB Configuration USB Mass Storage Driver Support Enables disables USB mass storage driver support USB transfer time out The time o...

Страница 54: ...r where Auto uses default value for Root port 100ms and for Hub port the delay is taken from Hub descriptor B 2 5 TPM 2 0 Configuration Security Device Support Enables disables BIOS support for securi...

Страница 55: ...erarchy Enables disables Storage Hierarchy Endorsement Hierarchy Enables disables Endorsement Hierarchy TPM 2 0 UEFI Spec Version Selects TCG2 Spec Version Support Physical Presence Spec Version Direc...

Страница 56: ...GE COMPUTING B 2 6 AMT Configuration AMT BIOS Features When disabled AMT BIOS features are no longer supported and user is no longer able to access MEBx Setup MEBx Hotkey Pressed Enables disables auto...

Страница 57: ...tion COM1 Control Selects COM1 mode from RS232 RS422 or RS485 COM2 Control Selects COM2 mode from RS232 RS422 or RS485 LAN 1 Intel I219 Enables disables I219 LAN1 LAN 2 Intel I211AT Enables disables I...

Страница 58: ...48 BIOS Setup Leading EDGE COMPUTING B 2 8 NCT6106D HW Monitor Displays CPU Board Temperatures System fan speeds and vari ous Voltages...

Страница 59: ...BIOS Setup 49 MVP 5100 System Fan Control Mode Configures fan control mode from among Manual Mode Auto Mode and SMART FAN IV Manual Mode Allows configuration of a set fan duty cycle...

Страница 60: ...50 BIOS Setup Leading EDGE COMPUTING Auto Mode Fan runs at automatic speed for optimal thermal solution...

Страница 61: ...BIOS Setup 51 MVP 5100 SMART FAN IV Four temperatures and four fan duty cycles with three avail able fan speed presets can be user configured...

Страница 62: ...Setup Leading EDGE COMPUTING B 2 9 BIOS Watchdog Timer BIOS POST Watchdog Disable disables WatchDog Timer Second Mode enables Watch dog Timer in second mode Minute Mode enables Watchdog Timer in minu...

Страница 63: ...BIOS Setup 53 MVP 5100 B 2 10 NVME Configuration Displays NVMe device status...

Страница 64: ...54 BIOS Setup Leading EDGE COMPUTING B 2 11 Network Stack Configuration Network Stack Enables disables UEFI Network Stack...

Страница 65: ...e 4G Decoding Enables disables 64bit capable devices to be decoded in Above 4G Address Space only when system supports 64 bit PCI Decod ing WARNING Setting incorrect or conflicting values in Chipset B...

Страница 66: ...OS Setup Leading EDGE COMPUTING B 3 1 System Agent SA Configuration System Agent SA Configuration Displays and configures VT d capability and provides settings for Memory Graphics and DMI OPI configur...

Страница 67: ...BIOS Setup 57 MVP 5100 B 3 1 1 Memory Configuration Memory Configuration Displays memory speed size maker and configuration...

Страница 68: ...s Configuration Internal Graphics Keeps IGFX enabled based on Setup options GTT Size Selects GTT Size Aperture Size Selects Aperture Size DVMT Pre Allocated Selects DVMT 5 0 Pre Allocated Fixed Graphi...

Страница 69: ...al Gfx Mem Selects DVMT5 0 Total Graphic Memory size used by Internal Graphics Device B 3 1 3 DMI OPI Configuration DMI OPI Configuration Displays DMI link speed and width DMI Max Link Speed Sets DMI...

Страница 70: ...60 BIOS Setup Leading EDGE COMPUTING B 3 2 PCH IO Configuration PCH IO Configuration Configures SATA Security and HD Audio...

Страница 71: ...d RST Configuration SATA Mode Selection Determines how SATA controller s operate SATA Controller Speed Sets maximum speed the SATA controller can support CFast Card Enables disables CFast Card Hot Plu...

Страница 72: ...62 BIOS Setup Leading EDGE COMPUTING SATA HDD 1 Enables disables SATA HDD 1 SATA HDD 2 Enables disables SATA HDD 2...

Страница 73: ...BIOS Setup 63 MVP 5100 B 3 2 2 Security Configuration BIOS Lock Enables disables PCH BIOS Lock Enable Required to be enabled to ensure SMM flash protection...

Страница 74: ...64 BIOS Setup Leading EDGE COMPUTING B 3 2 3 HD Audio Configuration Audio Output Selection Selects Audio Output...

Страница 75: ...BIOS Setup 65 MVP 5100 B 3 2 4 M 2 Device Configuration M 2 Port Device Link Selection Configures M 2 port PCIe Link as X1 or X2...

Страница 76: ...is set access is limited and the password requested on Setup If User password is set it acts as a power on password and must be entered to boot or enter setup Administrator Password Sets Administrato...

Страница 77: ...the System is in User mode Mode change requires platform reset Secure Boot Mode Selects from Standard or Custom In Custom Secure Boot Policy variables can be configured by a physically present user w...

Страница 78: ...ng EDGE COMPUTING B 5 Boot Setup Prompt Timeout Number of seconds before setup activation key is launched with 65535 0xFFFF setting indefinite waiting Bootup Num Lock State Sets keypad Number Lock sta...

Страница 79: ...OST and displayed Target Boot Option and click to select the desired device UEFI USB Hard Drive Disk Drives BBS Priorities Specifies Boot Device Priority sequence from available UEFI USB Drives Option...

Страница 80: ...and Exit Exits system setup after saving the changes Discard Changes and Exit Exits system setup without saving any changes Save Changes and Reset Resets the system setup after saving changes Discard...

Страница 81: ...igned for maximum system stability but less than maximum performance Select Restore Defaults if the computer encounters system configuration problems Save as User Defaults Saves all changes so far as...

Страница 82: ...72 BIOS Setup Leading EDGE COMPUTING This page intentionally left blank...

Страница 83: ...e generated signal is sent to reset the system C 1 WDT with API Windows The WDT API library files and a demo program incl source code can be downloaded from https www adlinktech com Products Industria...

Страница 84: ...the watchdog timer Return codes TRUE if timeout value of watchdog timer is successfully set FALSE if timeout value of watchdog timer is failed to set StartWDT Start the watchdog timer function Once t...

Страница 85: ...the initial timeout value specified in SetWDT function ResetWDT or StopWDT should be called before the expiration of the watchdog timer or the system will reset Syntax C C BOOL ResetWDT Parameters No...

Страница 86: ...PC IO NCT6102D to enter config mode EnterConfig void outp 0x4E 0x87 outp 0x4E 0x87 Config LPC IO to exit config mode ExitConfig void outp 0x4E 0xAA Read byte from LPC IO register unsigned char r_reg u...

Страница 87: ...unit as second w_reg 0xF0 r_reg 0xF0 0x04 start the Watchdog w_reg 0x30 0x01 set timeout value as 30 seconds WDT start automatically while timeout value is set w_reg 0xF1 0x1E printf n printf WDT is...

Страница 88: ...78 Watchdog Timer WDT Function Library Leading EDGE COMPUTING printf WDT is disable Program is terminating ExitConfig return 0...

Страница 89: ...e DI O function library for MVP 5100 series include the header file awl h and linkage library awl lib in the C project DI O functions are as follows AwlDioGetValue Reads the digital logic state of a d...

Страница 90: ...TING Parameter s Index Indexes the digital logic state of MVP 5100 digital input chan nels 1 to 8 bit 0 to 7 Value Sets the digital logic state of MVP 5100 digital output channels 1 to 8 bit 0 to 7 to...

Страница 91: ...45 of the National Electrical Code and NFPA 75 X To avoid electrical shock and or damage to device Z Keep device away from water or liquid sources Z Keep device away from high heat or humidity Z Keep...

Страница 92: ...nnect the power supply cord before loosening the thumbscrews and always fasten the thumbscrews with a screwdriver before starting the system up X It is recommended that the device be installed only in...

Страница 93: ...formation conformes l article 645 du National Electrical Code et la NFPA 75 X Pour viter les chocs lectriques et ou d endommager l appareil Z Tenez l appareil l cart de toute source d eau ou de liq ui...

Страница 94: ...ppareil ne fonctionne pas ou ne fonctionne pas selon le manuel de l utilisateur X L appareil est tomb et ou a t endommag et ou pr sente des signes vidents de dommage X D branchez le cordon d alimentat...

Страница 95: ...s de S curit Importante 85 MVP 5100 RISQUE DE BR LURES Partie chaude Ne touchez pas cette surface cela pourrait entra ner des blessures Pour viter tout danger laissez la surface refroidir avant de la...

Страница 96: ...86 Consignes de S curit Importante Leading EDGE COMPUTING This page intentionally left blank...

Страница 97: ...08 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China...

Отзывы: