![ADLINK Technology MECS-7211 Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/adlink-technology/mecs-7211/mecs-7211_user-manual_2852842057.webp)
Preliminary
57
MECS-7211
5.3.2 Sub-Menu: Console Redirection Settings
Aptio Setup Utility – Copyright (C) 2017 American Megatrends, Inc.
Advanced
Console Redirection Settings
Emulation: ANSI:
Extended
ASCII
char
Terminal Type
[VT100+]
set. VT100: ASCII char
Bits per second
[115200]
set. VT100+: Extends
Data Bits
[8]
VT100 to support color,
Parity [None]
function
keys,
etc.
Stop Bits
[1]
VT-UTF8: Uses UTF8
Flow Control
[None]
encoding to map Unicode
VT-UTF8 combo key support
[80x24]
chars onto 1 or more
Recorder [Enable]
Resolution 100x31
[Disabled]
Putty KeyPad
[Disabled]
[VT100]
><: Select Screen
^v: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F8: Previous Values
F9: Optimized Default
F10: Save & Exit
ESC: Exit
Version 2.19.1268. Copyright (C) 2017 American Megatrends, Inc.
BIOS Item
Options
Description
Terminal Type
VT100
VT100+
VT-UTF8
ANSI
Configure the type of console
emulation.
Emulation:
ANSI:
Extended ASCII char set.
VT100:
ASCII char set.
VT100+:
Extends VT100 to support
color, function keys, etc.
VT-UTF8:
Uses UTF8 encoding to map
Unicode chars onto 1 or more bytes.
Bits per second
9600
19200
38400
57600
115200
Selects serial port transmission speed.
The speed must be matched on the
other side. Long or noisy lines may
require lower speed.
Data Bits
7
8
Configure the number of data bits in
each transmitted or received serial
character for both serial ports.
Parity
None
Even
Configures if parity bit is generated
(transmit data) or checked.