31
MECS-6110
3.9 Login
to
the
BMC via Console Port
Step 1
Set the Console Port to BMC mode using CN15/16 on the mother board inside the chassis
(see
Console Port Mode
CN15
CN16
default
1-2
1-2
BMC
2-3
2-3
Step 2
Use the included RJ-45 to DB-9 console port adapter cable to connect the PC to the RJ-45
console port of the MECS-6110 (see
on page 8). See
Dual USB 3.0 and RJ-45 Console Port
on page 45 for the adapter cable pin definition.