6.6

Security Menu

This menu contains the settings for security in the system.

When selecting a HDD to configure passwords, BIOS will enter a

new BIOS setup (shown below). The method of configuring HDD

password is the same as that for BIOS passwords. Once pass-

word the is set, the status will be shown on the screen, such as

‘INSTALLED’ for ‘HDD User Pwd Status’. When there is no HDD

user password installed, you can always change the master pass-

word without confirming the latest installed password. Once the

HDD user password is installed, the HDD master password is can-

not be changed.

BIOS Item

Options

Description

Administrator 

Password

Enter to set 
password

Configure/Clear Administrator 

Password.
When pressing enter, a menu will be 

popped up for creating new 

password. When password installed, 

press enter without inputting 

password, it will clear password.

User Password

Enter to set 
password

Configure/Clear User Password. 

When pressing enter, a menu will be 

popped up for creating new 

password. When password installed, 

press enter without inputting 

password, it will clear password.

Secure Boot menu

Submenu

P1:xxxx

Submenu

For HDD security, it will list all HDD 

detected on motherboard. Select the 

HDD and then press enter can 

figure/clear HDD password.

Содержание DMI-1210

Страница 1: ...Leading EDGE COMPUTING Manual Rev 1 1 Revision Date February 21 2020 Part No 50 1Z284 1010 DMI 1210 Driver Machine Interface User s Manual...

Страница 2: ...ii Revision History Leading EDGE COMPUTING Revision History Revision Release Date Description of Change s 1 0 2019 02 20 Initial release 1 1 2020 02 21 Correct USB 1 1 M8 Connector pinout...

Страница 3: ...ges arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages Environmental Responsibility ADLINK is committed to fulfill its social re...

Страница 4: ...e harm For more information go to www P65Warnings ca gov TrademarksProduct names mentioned herein are used for identi fication purposes only and may be trademarks and or registered trademarks of their...

Страница 5: ...3 Mechanical Layout 8 2 4 Mechanical Dimensions 11 2 5 Power Specifications 12 2 5 1 Power Consumption 12 2 5 2 System Power Features 13 3 Getting Started 15 3 1 Removing the Rear Cover 15 3 2 Install...

Страница 6: ...3 Main Setup 59 6 3 1 BIOS Information 59 6 3 2 System Information 60 6 3 3 System Time System Date 60 6 3 4 Board Information 61 6 4 Advanced Menu 62 6 4 1 CPU Configuration 63 6 4 2 Graphic Configur...

Страница 7: ...set Menu 75 6 5 1 North Bridge 75 6 5 2 South Bridge 75 6 5 3 Uncore Configuration 76 6 5 4 South Cluster Configuration 77 6 5 5 HD Audio Configuration 77 6 6 Security Menu 84 6 6 1 Secure Boot 86 6 7...

Страница 8: ...viii Table of Contents Leading EDGE COMPUTING This page intentionally left blank...

Страница 9: ...ront Layout 8 Figure 2 3 DMI 1210 Rear I O Layout 9 Figure 2 4 DMI 1210 Side I O Layout 10 Figure 2 5 DMI 1210 Bottom I O Layout 10 Figure 2 6 DMI 1210 Dimensions 11 Figure 3 1 DMI 1210 Mounting Hole...

Страница 10: ...x List of Figures Leading EDGE COMPUTING This page intentionally left blank...

Страница 11: ...t 46 Table 5 4 GbE1 GbE2 M12 Connector Pinout 47 Table 5 5 Audio M8 Connector Pinout 47 Table 5 6 MVB Bus Female DB9 Connector Pinout 48 Table 5 7 MVB Bus Male DB9 Connector Pinout 49 Table 5 8 CAN Bu...

Страница 12: ...xii List of Tables Leading EDGE COMPUTING This page intentionally left blank...

Страница 13: ...n systems surveillance system control display unit or in railway diagnostics and communications applications 1 2 Features X Intel Atom x5 E3930 processor 1 8GHz X 12 1 color display 4 3 1024x768 pixel...

Страница 14: ...J45 Ethernet cable X 1x 4 pin M8 to Type A USB 1 1 cable X 1x 6 pin M8 to microphone and speaker cable X 2x 9 pin D sub male to female cables for MVB PC 104 MVB Kit P N 91 95239 200E X 1x PC 104 MVB c...

Страница 15: ...P N 30 60099 0000 X 2x internal RF cables P N 30 60066 0000 Mini PCIe card Wi Fi BT Kit P N 91 95239 600E X 1x Mini PCIe GSM TD SCDMA CDMA WCDMA LTE mod ule AMPAK AP12356_I X 2x external antennas P N...

Страница 16: ...4 Leading EDGE COMPUTING This page intentionally left blank...

Страница 17: ...d teaming USB 1x USB 1 1 port via M8 connector with 2kV isolation 1x USB 3 0 Type A port with dust cover for maintenance Serial 2x RS232 422 485 serial ports via DB 9 Audio Mic in and Line out port vi...

Страница 18: ...out 274 5 x 216 9 mm Environmental Operating Temperature 25 C to 70 C EN50155 T3 class Storage Temperature 40 C to 85 C Humidity 10 90 RH operating non condensing 5 95 RH storage EN 60068 2 30 EN 5015...

Страница 19: ...SB 1 1 M8 Port x1 Mini PCIe Con x1 SIM Slot SIM Slot 32 func key box header 8x GPIO Wafer Backlight Volume key Wafer Power M12 Con 24 36V or 72 110VDC 40 input Light Sensor Cap Touch Panel Opt USB Cam...

Страница 20: ...ut Front View The status LEDs are located on the right side of the bezel and the ambient brightness sensor at the top of the bezel as shown Figure 2 2 DMI 1210 Front Layout Power GbE Activity Serial P...

Страница 21: ...connector A5 3G 4G Aux antenna SMA connector X1 X2 COM1 COM2 DB9 connectors X3 USB 1 1 M8 connector X4 X5 GbE1 GbE2 M12 connectors X6 Audio M8 connector X7 X8 MVB CAN bus DB9 connectors X9 DC power i...

Страница 22: ...10 Leading EDGE COMPUTING Side View Figure 2 4 DMI 1210 Side I O Layout Bottom View Figure 2 5 DMI 1210 Bottom I O Layout USB2 CFast slot...

Страница 23: ...ons Figure 2 6 DMI 1210 Dimensions Dimensions in mm 310 248 33 75 186 50 31 10 247 80 27 75 31 10 7 50 155 R5 4x M6 through hole 10 4x90 R2 87 30 27 90 101 10 1 224 286 310 RUBBER WIDTH 248 RUBBER WID...

Страница 24: ...m temperature Input Voltage Loading Setup Voltage Current Power Cons 24VDC Stress 100 loading on CPU GPU RAM by running Intel TAT tool 24 1V 0 9A 22 0W 24VDC S3 mode 24 1V 0 28A 6 83W 24VDC S4 mode 24...

Страница 25: ...will shut down and try to restart every 6 seconds until the over current con dition is corrected Input Over Temperature Protection Power will automatically shut down when the operating tempera ture o...

Страница 26: ...14 Leading EDGE COMPUTING This page intentionally left blank...

Страница 27: ...15 DMI 1210 3 Getting Started 3 1 Removing the Rear Cover To install the optional modules first remove the rear cover as described below 1 Remove the cover on the USB2 slot as shown USB Cover...

Страница 28: ...ING 2 Remove all the screws indicated silver color NOTE NOTE Do NOT remove the black screws These are used to secure the heat spreaders inside the cover M3 Screws others are M2 5 screws Note Do NOT re...

Страница 29: ...17 DMI 1210 3 Remove the rear cover It may be necessary to use a tool such as a flat head screwdriver to lift the cover away from the display frame Rear Cover...

Страница 30: ...ng EDGE COMPUTING 3 2 Installing a PC 104 MVB Module optional Follow the instructions below to install a PC 104 MVB module 1 Remove the cover on the X7 and X8 D SUB port openings D SUB port cover M2 5...

Страница 31: ...19 DMI 1210 2 Install the PC 104 MVB module with four M3 screws as shown MVB Module M3 Screws...

Страница 32: ...two D SUB cables to the PC 104 MVB module and X7 X8 ports as shown Use the female to male cable for the X7 port and male to female cable for the X8 port Note that the 90 D SUB connectors go to the mod...

Страница 33: ...21 DMI 1210 3 3 Installing Wi Fi and LTE Modules optional Follow the instructions below to install Mini PCIe Wi Fi and LTE modules 1 Remove the caps on the A2 A5 SMA connector openings Remove Caps...

Страница 34: ...modules insert the SMA connectors into the openings and secure with washers and nuts as shown Route the cables as shown below CAUTION Make sure that the cables are clear of the CPU as this will affect...

Страница 35: ...described in Step 2 on page 22 above for Mini PCIe LTE and Wi Fi modules 2 Connect the one end of the Y split cable to the module and the two D SUB connectors to the X7 and X8 ports using the nut scre...

Страница 36: ...3 1 below M5 thread or 5 5 through hole 2 Attach I O cables to the device before installing into the panel if rear access will be limited after installation see Mechanical Layout on page 8 3 Place th...

Страница 37: ...25 DMI 1210 Figure 3 2 Mounting the DMI 1210 M5xL40 Screw O Ring M5 Nut 5 5 through hole Platform DMI 1210 M5 Screw torque 10 0 Kgf cm for...

Страница 38: ...E COMPUTING 3 6 CFast Card Installation To install or remove the CFast card remove the M2 5 screws securing the CFast slot cover and remove the cover Insert the CFast card and secure the cover CFast C...

Страница 39: ...erminal X Slide the ring terminal onto the ground stud and secure it with the locking M4 nut as shown Connecting Peripherals Connect all the peripheral devices needed for your system to func tion CAUT...

Страница 40: ...tem may only be carried out by personnel qualified for the specific task and who have the training and experience to identify risks and avoid potential hazards Z Make sure that a ground cable has been...

Страница 41: ...he first boot device is the onboard eMMC To enter the BIOS setup menu to change the boot device order enter Del or Esc The DMI 1210 can be delivered with Linux Ubuntu 16 04 LTS or Windows 10 already i...

Страница 42: ...hics win64_15 60 01 4877 exe 3 LAN LAN APPS SETUP SETUPBD Winx64 SetupBD exe 4 Audio Audio 0008 64bit_Win7_Win8_Win81_Win10 _R281 exe 5 PenMount Windows USB Driver PenMount Win dows USB Driver V2 4 5...

Страница 43: ...31 DMI 1210 11 Wi Fi To install the Wi Fi driver do the following Open the Device Manager...

Страница 44: ...32 Leading EDGE COMPUTING R click on Other Devices Network Controller and select Update Driver Software...

Страница 45: ...33 DMI 1210 Select Browse my computer for driver softwaret...

Страница 46: ...34 Leading EDGE COMPUTING Navigate to the path WiFi and BT module_BCM4356 WiFi x64 DHD_REL_1 558 53 33_Win10_x64 and click Next...

Страница 47: ...35 DMI 1210 Select Install this driver software anyway and then click Close when the driver has finished installing...

Страница 48: ...TING Navigate to the path WiFi and BT module_BCM4356 WiFi Right click on the file Install_nvram bat and click Yes in the User Account Control pop up This will copy the file 4356r2nvram txt into C Wind...

Страница 49: ...37 DMI 1210 Open the Device Manager R click on Broadcom 802 11ac Wireless PCEI Full Dongle Adapter and disable it Click Yes when asked to confirm...

Страница 50: ...38 Leading EDGE COMPUTING R click on Broadcom 802 11ac Wireless PCEI Full Dongle Adapter and enable it...

Страница 51: ...39 DMI 1210 Wi Fi will now be functional...

Страница 52: ...40 Leading EDGE COMPUTING 3 9 2 Linux Drivers To install the Linux drivers please download and follow the instructions in the DMI 1210 Linux Drivers Installation Guide...

Страница 53: ...earch http www amtouch com tw downloads penmount drivers Uncompress the package and install it by doing the following Uncompress PenMount calibration tool tar jxvf pmLinux Ubuntu_12 04 18 04_32_64bit_...

Страница 54: ...reen perform the following steps 1 Select Filter and search for Pen to find the PenMount Utility 2 Open the utility select the number of points you wish to calibrate and click on Calibrate to start 3...

Страница 55: ...als_read c o als_read perform test application to read out Lux value als_read sample logs root adlink SP AL home adlink ALS als_read DBG seeking dev i2c 1 DBG write data 0x00 fail DBG read data failur...

Страница 56: ...tness Set brightness to min echo 0 sys devices pci0000 00 0000 00 02 0 drm card0 card0 eDP 1 intel_backlight brightnes s Set brightness to max echo 96000 sys devices pci0000 00 0000 00 02 0 drm card0...

Страница 57: ...locations Table 5 1 Status LED Definitions LED Function Power Status LED is on when DC Power is connected and system is powered on GbE1 2 Activity LED flashes when Ethernet port is active COM1 2 Tx R...

Страница 58: ...cations COM1 X1 COM2 X2 DB9 Connectors Table 5 2 COM1 COM2 Serial Port Pinout USB 1 1 M8 Connector X3 Table 5 3 USB 1 1 M8 Connector Pinout Pin RS 232 RS 422 RS 485 Pin1 DCD TXD D Pin2 RXD TXD D Pin3...

Страница 59: ...GbE1 GbE2 M12 Connector Pinout Audio M8 Connector X6 Table 5 5 Audio M8 Connector Pinout Pin Signal Name 1 MDO0P 2 MDO0N 3 MDO1P 4 MDO1N 5 MDO3P 6 MDO3N 7 MDO2N 8 MDO2P Pin Signal Name 1 MIC 2 GND 3 S...

Страница 60: ...d MVB bus line with RS485 level 2 A data N Inverted MVB bus line with RS485 level 3 NC Not connected 4 B data P bidirectional Non inverted MVB bus line with RS485 level 5 B data N Inverted MVB bus lin...

Страница 61: ...line with RS485 level 2 A data N Inverted MVB bus line with RS485 level 3 NC Not connected 4 B data P bidirectional Non inverted MVB bus line with RS485 level 5 B data N Inverted MVB bus line with RS...

Страница 62: ...Bus Male DB9 Connector Pinout DC power input M12 connector X9 Table 5 9 DC Power Input Pinout Pin COM3 Function COM4 Function 1 NC NC 2 Port 0 CAN L Port 1 CAN L 3 NC NC 4 NC NC 5 NC NC 6 GND GND 7 Po...

Страница 63: ...DMI 1210 USB2 Connector USB 3 0 Table 5 10 USB2 USB 3 0 Pinout Pin Signal Name 1 5V_USB3 2 USB2_P0_DN_CN 3 USB2_P0_DP_CN 4 GND 5 USB3_P0_RXN_CN 6 USB3_P0_RXP_CN 7 GND 8 USB3_P0_TXN_CN 9 USB3_P0_TXP_C...

Страница 64: ...tion Pin Signal Name Ground S1 SATA_TX P S2 SATA_TX N S3 Ground S4 SATA_RX N S5 SATA_RX P S6 Ground S7 CFast_CDI P1 Ground P2 NC P3 NC P4 NC P5 NC P6 Ground P7 CFast_LED1 P8 CFast_LED2 P9 NC P10 NC P1...

Страница 65: ...53 DMI 1210 Internal USB 2 0 Header CN16 Table 5 12 Internal USB 2 0 Header CN16 Pinout Figure 5 1 Internal USB 2 0 Header CN16 Location Pin Signal Name 1 5V 2 USB_D 3 USB_D 4 GND 5 NC 6 NC 1 CN16...

Страница 66: ...54 Leading EDGE COMPUTING This page intentionally left blank...

Страница 67: ...r menus Setup Menu The main BIOS setup menu is the first screen that you can navi gate Each main BIOS setup menu option is described in this user s guide The Main BIOS setup menu screen has two main f...

Страница 68: ...tup utility uses a key based navigation system called hot keys Most of the BIOS setup utility hot keys can be used at any time during the setup navigation process NOTE NOTE There is a hot key legend l...

Страница 69: ...reen Press the F1 key to open the General Help screen F2 The F2 key on your keyboard is the previous values key It is not displayed on the key legend by default To set the previous values settings of...

Страница 70: ...ve made and exit Setup Press the F10 key to save your changes The following screen will appear Press the Enter key to save the configuration and exit You can also use the Arrow key to select Cancel an...

Страница 71: ...as built MRC Version Info only w x y z Display the revision of MRC code which is implemented in BIOS GOP Version Info only x y zzzz VBIOS Version When video option ROM is set to Legacy Only this will...

Страница 72: ...ting the system CPU Frequency Info only XXXX MHz Display CPU frequency Total Memory Info only XXXX MB DDRx Display total memory size used on the motherboard and memory type Memory Frequency Info only...

Страница 73: ...in minutes the system is running in S0 state Current Runtime Info only The returned value specifies the time in seconds the system is running in S0 state This counter is cleared when the system is rem...

Страница 74: ...features functions Graphic Configuration Submenu For setting graphic controller parameters Power Management Submenu System Management Submenu Thermal Management Submenu Watchdog Timer Submenu Super IO...

Страница 75: ...ed C status Disable Enable Enables disables C1E where when enabled CPU will switch to minimum speed when all cores enter CStates Max Package C Status PC2 PC1 C0 Sets the Max Package C State supported...

Страница 76: ...ual LVDS bus Set single dual LVDS bus mode DE Polarity Active High Active Low Configure DE Polarity Vsync Polarity Active High Active Low Configure Vsync Polarity Hsync Polarity Active High Active Low...

Страница 77: ...es or disables lock of legacy resource mPCIe Slot Wake Disabled Enabled Enables disables PCI Express slot wake capability FM Board Wake Disabled Enabled Enables disables FM Board wake capability RTC W...

Страница 78: ...re was built SEMA Bootloader Read only Show SEMA bootloader s version Build Date Read only Show when SEMA bootloader was built SEMA Features Submenu Flags Submenu BIOS Item Options Description SEMA Su...

Страница 79: ...If this item is shown it means SEMA supports System Fan 1 DTS register Info only If this item is shown it means SEMA supports DTS register DTS offset registers Info only If this item is shown it means...

Страница 80: ...ensor Startup Read only Show the board temperature at system power up Min Read only Show the minimum board temperature after system boot Max Read only Show the maximum board temperature after system b...

Страница 81: ...mount of time after power up Pressing F12 key during startup will disable the power up watchdog timer RunTime Watchdog Enabled Disabled Enables disables RunTime watchdog which when enabled resets the...

Страница 82: ...0 11 12 IO 2F8 IRQ 3 4 5 7 9 10 11 12 IO 3E8 IRQ 3 4 5 7 9 10 11 12 IO 2E8 IRQ 3 4 5 7 9 10 11 12 Select an optimal setting for Super IO device Serial Port x Control RS232 RS422 RS485 Select serial po...

Страница 83: ...be matched on the other side Long or noisy lines may require lower speed Data Bits 7 8 Configure the number of data bits in each transmitted or received serial character for both serial ports Parity...

Страница 84: ...XON XOFF VT UTF8 Combo Key Support Disabled Enabled Enable VT UTF8 combination key support for ANSI VT100 terminals Recorder Mode Disabled Enabled With this mode enabled only text will be sent This is...

Страница 85: ...Enabled Enables disables BIOS support for security device When enabled OS will not show the security device and TCG EFI protocol and INT1A interface will not be available BIOS Item Options Descriptio...

Страница 86: ...the delay is taken from the Hub descriptor BIOS Item Options Description NIC Configuration Submenu For configuring link speed and wake function Blink LEDs Value Range Identifies the physical network p...

Страница 87: ...ons Description Memory Information Info only Total Memory Info only Display Total Memory Size Memory Voltage Info only Display Memory Voltage Memory Slot0 Info only Display Installed Memory Slot0 Info...

Страница 88: ...ce IGD when selected as the Primary Video Adaptor Disable Always disable IGD Primary Display IGD PCIe HG Select which of IGD PCI Graphics device should be Primary Display Aperture Size 128MB 256MB 512...

Страница 89: ...A Drives Submenu SCC Configuration Submenu USB Configuration Submenu Miscellaneous Configuration Submenu BIOS Item Options Description HD Audio Support Disabled Enabled Enables disables HDA Audio Audi...

Страница 90: ...y for the most optimum power savings Enable Enable PCIe root port Disable Disable PCIe root port BIOS Item Options Description PCI Express Root Port X Disable Enable Auto Control the PCI Express Root...

Страница 91: ...Express System Error on Correctable Error Enable Disable PME SCI Disable Enable PCI Express PME SCI Enable Disable Hot Plug Disable Enable PCI Express Hot Plug Enable Disable PCIe Speed Auto Gen1 Gen2...

Страница 92: ...ult Maintain default BIOS flow PCIE LTR Lock Disable Enable PCIE LTR Configuration Lock PCIe Selection De emphasis Disable Enable When the Link is operating at 5 0 GT s speed this bit selects the leve...

Страница 93: ...If enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type Hard Disk...

Страница 94: ...nabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type Hard Disk Drive Solid State Drive Identify the SATA port is connected to Solid State Drive or Hard Disk Drive SATA Por...

Страница 95: ...DCI Support Disabled Enabled Enables disables XDCI support XHCI Disable Compliance Mode Disabled Enabled Selects XHCI Disable Compliance Mode USB HW Mode AFE Comparators Disabled Enabled Enables disab...

Страница 96: ...password is installed the HDD master password is can not be changed BIOS Item Options Description Administrator Password Enter to set password Configure Clear Administrator Password When pressing ent...

Страница 97: ...fied only when successfully unlocked with Master Password in POST HDD PASSWORD CONFIGURATION Security Supported Yes Security Enabled Yes Security Locked No Security Frozen No Select Screen HDD User Pw...

Страница 98: ...re Boot BIOS Item Options Description System Mode Info only Secure Boot Info only Secure Boot Control Disabled Enabled Secure Boot can be enabled if 1 System running in User mode with enrolled Platfor...

Страница 99: ...ect the keyboard NumLock state after system boot Quiet Boot Disabled Enabled Enabled will show splash screen during POST Disabled will show boot message during POST Fast Boot Disabled Enabled Enable o...

Страница 100: ...et system do reset to boot system Discard Changes and Reset Enter Discard all changed settings and let system do reset to boot system Save Changes Enter Save all changed settings Discard Changes Enter...

Страница 101: ...urn off power and unplug any power cords cables X To avoid electrical shock and or damage to equipment Z Keep equipment away from water or liquid sources Z Keep equipment away from high heat or high h...

Страница 102: ...ed by authorized technicians when Z The power cord or plug is damaged Z Liquid has penetrated the equipment Z It has been exposed to high humidity moisture Z It is not functioning or does not function...

Страница 103: ...08 360 0200 Toll Free 1 800 966 5200 USA only Fax 1 408 360 0222 Email info adlinktech com ADLINK Technology China Co Ltd 300 Fang Chun Rd Zhangjiang Hi Tech Park Pudong New Area Shanghai 201203 China...

Отзывы: