Signal Connections
45
AMP-304C
With encoder feedback input signals, a position comparison trig-
ger function is available for each axis. Any 16-channel position
comparison trigger output can be assigned as a pulse output
mode with width configurable or a toggle output mode. The AMP-
304C provides 256 position comparison buffer points for each
axis, including Linear and Table comparison modes. Position-
reusable is also available in Table comparison modes. For more
information, see the APS Function Library User’s Manual.
3.5.3
Manual Pulser Input Signal (PA/PB)
The AMP-304C provides one set of manual pusler functions
through PA/PB for all axes. CW/CCW and 1x/2x/4x AB Phase
modes are supported for receiving external drive pulses. For more
information, see the APS Function Library User’s Manual.
CN5 Pin No.
Signal Name
2
PA+
3
PA-
4
PB+
5
PB-
Digital
Isolator
FPGA
Connector
CMP
CMP
EGND
E24V
VDD
330
G
S
D
G
D
S
4.7K
CN3
1
2
3
Motion
Chip
Connector
PA+ / PB+
PA- / PB-
D3.3V
100pF
330