ADJ SABER SPOT GO Скачать руководство пользователя страница 1

User Instructions

SABER SPOT GO

Содержание SABER SPOT GO

Страница 1: ...User Instructions SABER SPOT GO...

Страница 2: ...from power when not in use Thank you FCC STATEMENT This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interfer...

Страница 3: ...nstallation I Safety Strap Overview DMX Addressing DMX Modes Color Macro Chart System Menu Operating Instructions WiFly Set Up I WiFly Master Slave I Runtime Mode ADJ UC IR Airstream IR Control Dimmer...

Страница 4: ...and other similar locations For best results use fog or special effects smoke to enhance the beams projections These instructions contain important safety information regarding the use and maintenance...

Страница 5: ...enclosed warranty card to validate your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must...

Страница 6: ...s be sure to mount this unit in an area that will allow proper ventilation Allow about 6 15cm between this device and a wall Do not attempt to operate this unit if it becomes damaged This unit is inte...

Страница 7: ...s constructed in a way that no short circuit will occur which may cause smoke or fire DO NO DISASSEMBLE THE BATTERIES NEVER DISASSEMBLE THE BATTERIES Doing this may cause a internal short circuit in t...

Страница 8: ...xpectancy of the battery maybe shortened or the device in which the battery is used may be damaged by electrolyte gel leakage If the batteries cannot maintain a charge for long periods of time even wh...

Страница 9: ...attaching the unit is secure and is able to support a weight of 10 times the unit s weight Also always use a safety cable not included that can hold 12 times the weight of the unit when installing the...

Страница 10: ...Products LLC www adj com Saber Spot GO User Manual Page 9 Saber Spot GO Overview POWER IN LCD DISPLAY CONTROL PANEL MODE UP DOWN ENTER SAFETY CABLE RIGGING POINT POWER SWITCH CHARGING INDICATOR MAGNE...

Страница 11: ...fixtures to react in the same way in other words changing the settings of one channel will affect all the fixtures simultaneously If you set each fixture to a different DMX address each unit will star...

Страница 12: ...4 095 096 127 128 159 160 191 192 223 224 255 5 5 1 8 VALUES FUNCTIONS 3 CH 4 CH 4 CH 5 CH 6 CH 6 CH 7 CH 8 CH 8 CH 9 CH 11 CH 12 CH 1 1 1 RED FINE 0 100 WHITE 0 100 WHITE FINE 0 100 BLUE FINE 0 100 H...

Страница 13: ...O PROGRAM 9 AUTO PROGRAM 10 AUTO PROGRAM 11 AUTO PROGRAM 12 AUTO PROGRAM 13 GRADIENT EFFECT 000 001 020 021 040 041 060 061 080 081 100 101 120 121 140 141 160 161 180 181 200 201 220 221 240 241 250...

Страница 14: ...55 71 77 71 Color45 1 Color13 49 52 255 83 134 83 Color46 1 Color14 53 56 255 93 182 93 Color47 1 Color15 57 60 255 96 236 96 Color48 1 Color16 61 64 238 93 255 93 Color49 1 Color17 65 68 196 87 255 8...

Страница 15: ...Color43 169 172 119 130 199 0 74 Color44 173 176 147 164 212 0 71 Color45 177 180 88 2 163 0 83 Color46 181 184 0 38 86 0 93 Color47 185 188 0 142 208 0 96 Color48 189 192 52 148 209 0 93 Color49 193...

Страница 16: ...Manual DimCurve NO DMX White BL White Balance R255 G255 B255 W255 TempUnit Temp Unit C F Temp Val Temperature Value XXX F AUTOLOCK AUTOLOCK OFF ON IR Active IR Active OFF ON FlipDisplay Flip Disply OF...

Страница 17: ...f 13 built in programs 1 Press either the MODE UP or DOWN buttons until LOOK is displayed and press ENTER 2 Use the UP or DOWN buttons to find your desired program and press the ENTER button to confir...

Страница 18: ...built in show Blackout If the DMX signal is lost or interrupted the unit will automatically go into stand by mode Hold If the DMX signal is lost the fixture will stay in the last DMX setting If power...

Страница 19: ...ons until FlipDisplay is displayed press ENTER 2 The display will show either ON or OFF Press the UP or DOWN buttons to select ON to flip the display or OFF to keep the display normal 3 Press the ENTE...

Страница 20: ...channel setting on the WiFly WiFly Transceiver 2 After you have set the WiFly channel follow the DMX instructions on page 16 to select your desired DMX Channel mode and set your DMX address 3 Apply p...

Страница 21: ...app comes with 3 pages of control depending on the fixture you are using Please see below for IR functions including the cor responding app page Works with App page 1 STAND BY Pressing this button wil...

Страница 22: ...100 50 10 0 Time ms 0 Sec 255 255 0 0 Standard default 0 0 0 0 Stage 780 1100 1540 1660 TV 1180 1520 1860 1940 Architectural 1380 1730 2040 2120 Theatre 1580 1940 2230 2280 Dimming Curve Ramp Effect R...

Страница 23: ...ADJ Products LLC www adj com Saber Spot GO User Manual Page 22 Saber Spot GO Dimensional Drawing 6 8 172mm 6 3 160mm 3 5 90mm 5 127mm 3 9 100mm 6 3 158 97mm...

Страница 24: ...enses must be carried out periodically to optimize light output 1 Use normal glass cleaner and a soft cloth to wipe down the outside casing 2 Clean the external optics with glass cleaner and a soft cl...

Страница 25: ...or by reason of defects in material or workmanship The sole responsibility of ADJ Products LLC under this warranty shall be limited to the repair of the product or replacement thereof including parts...

Страница 26: ...Type Fixed Lithium Ion Battery Battery Energy 28 86WH Watt Hours Battery Weight 0 33 lbs 0 15kg Battery Voltage 11 1V Battery Capacity 2 6AH Total Lithium Ion Cells 3pcs Battery Wrap Material PVC Sle...

Отзывы: