background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

PROFINET / J1939

 

 

Document code: MN67610_ENG     Revision 1.001   Pagina 1 di 24

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
                                                                                          
 
 
 
 
 
 
 
 

User Manual 

Revision 1.001 
English 

 

PROFINET / J1939 - Converter 

 (Order Code:  HD67610-A1) 

 
for Website information:  

www.adfweb.com?Product=HD67610

 

 

for Price information: 

www.adfweb.com?Price=HD67610-A1

 

 
 

Benefits and Main Features: 

 

Very easy to configure 

 

Electrical isolation 

 

Two PROFINET ports 

 

Temperature range: -40°C/85°C (-40°F/185°F) 

For others PROFINET products see also the following link: 

 

Converter PROFINET to  

www.adfweb.com?Product=HD67600

      

(NMEA2000)

 

www.adfweb.com?Product=HD67601

      

(Serial RS232)

 

www.adfweb.com?Product=HD67601

      

(Serial RS485)

 

www.adfweb.com?Product=HD67602

      

(Modbus Master RS232)

 

www.adfweb.com?Product=HD67602

      

(Modbus Master RS485)

 

www.adfweb.com?Product=HD67603

      

(Modbus Slave RS232)

 

www.adfweb.com?Product=HD67603

      

(Modbus Slave RS485) 

www.adfweb.com?Product=HD67604

      

(PROFIBUS Master) 

www.adfweb.com?Product=HD67605

      

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67606

      

(CAN) 

www.adfweb.com?Product=HD67607

      

(CANopen) 

www.adfweb.com?Product=HD67608

      

(DeviceNet Master)

 

www.adfweb.com?Product=HD67609

      

(DeviceNet Slave) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

Other 
Products 

Содержание PROFINET / J1939

Страница 1: ...Converter PROFINET to www adfweb com Product HD67600 NMEA2000 www adfweb com Product HD67601 Serial RS232 www adfweb com Product HD67601 Serial RS485 www adfweb com Product HD67602 Modbus Master RS232...

Страница 2: ...e remind you that you need to check that the following document is Updated Related to the product you own To obtain the most recently updated document note the document code that appears at the top ri...

Страница 3: ...al interlocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the instal...

Страница 4: ...al Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET J1939 Document code MN67610_ENG Revision 1 001 Pagina 4 di 24 EXAMPLE OF CON...

Страница 5: ...es ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET J1939 Document code MN67610_ENG Revision 1 001 Pagina 5 di 24 CONNECTION SCHEME Figure 1 Connec...

Страница 6: ...on between CAN Power Supply CAN Ethernet Power Supply Ethernet Two directional information between J1939 bus and PROFINET bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35...

Страница 7: ...NET J1939 Document code MN67610_ENG Revision 1 001 Pagina 7 di 24 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vma...

Страница 8: ...p2 of Dip Switch A The first with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for upload the Project a...

Страница 9: ...owly 0 5Hz update in progress 3 BF bus fault red ON The Ethernet connection is defective the IP address exists several times in the network the own NameOfStation exists several times in the network no...

Страница 10: ...connection must be made using Connector3 and or Connector4 of HD67610 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Страница 11: ...ion 1 001 Pagina 11 di 24 J1939 For terminate the J1939 line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m A...

Страница 12: ...S 2000 XP Vista Seven 8 32 64bit When launching the SW67610 the right window appears Fig 2 Note It is necessary to have installed Net Framework 4 NEW PROJECT OPEN PROJECT The New Project button create...

Страница 13: ...y that you want to use This feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for PROFINET communication is...

Страница 14: ...read from PROFINET to J1939 it is an identifier In the field Source Address insert the address of the device that sends the frame If the field Transport Protocol is checked the frame use transport pro...

Страница 15: ...PGN insert the PGN of the data you would like to write from PROFINET to J1939 in J1939 protocol the PGN is an identifier In the field Source Address insert the address of the device that sends the fr...

Страница 16: ...IP address of the device you have to use this procedure Turn off the Device Put Dip2 of Dip Switch A at ON position Turn on the device Connect the Ethernet cable Insert the IP 192 168 2 205 Press the...

Страница 17: ...device is correctly update Note When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67610 A1 device Note When you receive the devi...

Страница 18: ...b com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET J1939 Document code MN67610_ENG Revision 1 001 Pagina 18 di 24 MECHANICAL DIMENSIONS Figure 8 Mechanica...

Страница 19: ...rdering part number is formed by a valid combination of the following HD67610 A 1 Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67610 PROFIN...

Страница 20: ...agina 20 di 24 PLC CONFIGURATION The configuration and commissioning of the PROFINET Converter as described on the following pages was accomplished with the help of the TIA Portal V11 software of Siem...

Страница 21: ...no Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET J1939 Document code MN67610_ENG Revision 1 001 Pagina 21 di 24 2 Import the module in the network connect the device to the P...

Страница 22: ...ronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual PROFINET J1939 Document code MN67610_ENG Revision 1 001 Pagina 22 di 24 3 Load the configurat...

Страница 23: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Страница 24: ...If while using your product you have any problem and you wish to exchange or repair it please do the following 1 Obtain a Product Return Number PRN from our internet support at www adfweb com Together...

Отзывы: