ADFweb.com Srl – IT31010 – Mareno – Treviso INFO:
www.adfweb.com
Phone +39.0438.30.91.31
User Manual
SNMP Agent / CANopen
Document code: MN67156_ENG Revision 1.100 Pagina 22 di 40
The data of the columns in the “Transmit PDO” have the
following meanings:
In the Field "
Cob-ID
" the address for the PDO is
defined;
In the Field "
Dimension
" the dimension of the
PDO is defined (it can be between 1 and 8);
In the Field "
Add B1
" the first byte where the
data will be loaded in the SNMP array is defined;
In the Field "
Add B2
" the second byte where the
data will be loaded in the SNMP array is defined
(only if
Dimension
> 1);
In the Field "
Add B3
" the third byte where the
data will be loaded in the SNMP array is defined
(only if
Dimension
> 2);
In the Field "
Add B4
" the fourth byte where the data will be loaded in the SNMP array is defined (only if
Dimension
> 3);
In the Field "
Add B5
" the fifth byte where the data will be loaded in the SNMP array is defined (only if
Dimension
> 4);
In the Field "
Add B6
" the sixth byte where the data will be loaded in the SNMP array is defined (only if
Dimension
> 5);
In the Field "
Add B7
" the seventh byte where the data will be loaded in the SNMP array is defined (only if
Dimension
> 6);
In the Field "
Add B8
" the eighth byte where the data will be loaded in the SNMP array is defined (only if
Dimension
> 7);
In the Field “
Send Time
” insert the interval used to send the PDO. The time is in milliseconds;
If the field “
On Change
” is checked, the gateway send the Transmit PDO when the data change the value;
In the field "
Mnemonic
" the description for the PDO is defined.
Figure 6b: “Set PDO Access – Transmit PDO” window