background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

EtherCAT Slave / CAN

 

 

Document code: MN67E07_ENG     Revision 1.000   Page 15 of 29

 

 

 

SOFTWARE OPTIONS: 

 

By  pressing  the  “

Settings

”  (

)  button    there  is  the  possibility  to  change  the  language  of  the  software  and  check  the  updatings  for  the 

compositor. 
 
In  the  section  “Language”  it  is  possible  to  change  the  language  of  the 
software. 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
In  the  section  “Connection  Options”,  it is  possible  to  check  if  there  are  some 
updatings of the software compositor in ADFweb.com website. 
Checking  the  option  “

Check  Software  Update  at  Start  of  Program

”,  the 

SW67E07 checks automatically if there are updatings when it is launched.

Содержание HD67E07-A1

Страница 1: ...ACnet Master www adfweb com Product HD67E06 BACnet Slave www adfweb com Product HD67E08 CANopen www adfweb com Product HD67E09 DeviceNet Master www adfweb com Product HD67E10 DeviceNet Slave www adfwe...

Страница 2: ...RRANTIES AND TECHNICAL SUPPORT 29 RETURN POLICY 29 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated R...

Страница 3: ...ice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation o...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave CAN Document code MN67E07_ENG Revision 1 000 Page 4 of 29 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave CAN Document code MN67E07_ENG Revision 1 000 Page 5 of 29 CONNECTION SCHEME Figure 1 Connection scheme for HD67E07 A1...

Страница 6: ...al information between EtherCAT bus and CAN bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compos...

Страница 7: ...7_ENG Revision 1 000 Page 7 of 29 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at...

Страница 8: ...he position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for...

Страница 9: ...Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 CAN comm green It blinks when a CAN message is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 4...

Страница 10: ...andard Ethernet packet or frame according to IEEE 802 3 is no longer received interpreted and copied as process data at every node The EtherCAT slave devices read the data addressed to them while the...

Страница 11: ...For terminating the CAN line with a 120 resistor it is necessary that the Dip1 of Dip Switch B is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC parameters Impedance 120 Ohm m...

Страница 12: ...ade using Connector8 of the HD67E07 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative to connections in ca...

Страница 13: ...ns with Windows called SW67E07 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present on ou...

Страница 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable EtherCAT Slave CAN Converter in order to configure another device in the same manner i...

Страница 15: ...language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to c...

Страница 16: ...EtherCAT Slave CAN Document code MN67E07_ENG Revision 1 000 Page 16 of 29 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Страница 17: ...Slave Name the name of the converter is defined In the field Node Address the ID of the converter is defined The means for the fields for the CAN are In the field Baudrate the baudrate of the CAN line...

Страница 18: ...therCAT Master Master To Slave SLAVE TO MASTER The means of the fields are If the field Enable is checked the EtherCAT variable is enabled In the field Type the data format of the EtherCAT variable is...

Страница 19: ...is enabled In the field Type the data format of the EtherCAT variable is defined In the field Lenght the dimension of the EtherCAT variable is defined In the field Name the name of the EtherCAT varia...

Страница 20: ...e COB from 1 to 8 is defined The field TimeOut is used for put at zero the data into EtherCAT array if the CAN frame arrives with a frequency less than the time expressed in the field If the value in...

Страница 21: ...MN67E07_ENG Revision 1 000 Page 21 of 29 In the field Byte7 insert the byte of the EtherCAT array where saving 7th byte of the CAN message In the field Byte8 insert the byte of the EtherCAT array whe...

Страница 22: ...ts or 2 0B 29 bits In the field Dimension the number of byte of the COB from 1 to 8 is defined If the field OnChange is checked the frame is sent when the data from EtherCAT change If the field OnCMD...

Страница 23: ...ere taking 6th byte of the CAN message In the field Byte7 insert the byte of the EtherCAT array where taking 7th byte of the CAN message In the field Byte8 insert the byte of the EtherCAT array where...

Страница 24: ...t cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of D...

Страница 25: ...ogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mor...

Страница 26: ...strial Electronic Devices ADFweb com S r l User Manual EtherCAT Slave CAN Document code MN67E07_ENG Revision 1 000 Page 26 of 29 MECHANICAL DIMENSIONS Figure 9 Mechanical dimensions scheme for HD67E07...

Страница 27: ...alid combination of the following HD67E07 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67E07 EtherCAT Slave CAN Converter Order Code HD6...

Страница 28: ...n systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycl...

Страница 29: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...

Отзывы: