LoRaWAN / S7comm Client

 

 

Document code: MN67D39_ENG     Revision 1.000   Page 26 of 30

 

 

 

LORAWAN PAYLOAD 
 

The LoRAWAN messages in Uplink and Downlink are structured into a defined format in order to recognize them from LoRaWAN gateway 
side and to understand to which bytes of the internal memory array they are associated. 
 
The payload of the LoRaWAN messages is defined in Hex format: 

 

The first byte refers to the row of the tables defined into “LoRaWAN Access” section of SW67D39: it can have a value between 0 and 
255 (0xFF); 

 

The following bytes will contain the data to be linked to the internal memory arrays of the converter (using “Start Byte” and “Num. 
Byte” of “LoRaWAN Access” section of SW67D39); 

 

Example 1: 

the converter is sending a LoRaWAN message related to row 4 of “LoRaWAN Access 

 LoRaWAN Uplink” table of “LoRaWAN Access” section 

of SW67D39 with a “Num. Byte” set of ‘4’. The data from these 4 bytes is “01 02 03 04” (hex). 
The payload of the LoRaWAN message will look like “04 01 02 03 04” where: 

 

04: index of the row of “LoRaWAN Access 

 LoRaWAN Uplink” table; 

 

01 02 03 04: data taken from internal memory array of the converter. 

 

Example 2: 

The external LoRaWAN gateway needs to send a LoRaWAN message to the converter and link it to row 3 of “LoRaWAN Access 

 LoRaWAN 

Downlink” table of “LoRaWAN Access” section of SW67D39. The “Num. Byte” set is ‘4’ and the data to be written is “55 66 77 88” (hex). 
The payload of the LoRaWAN message will look like “03 55 66 77 88” where: 

 

03: index of the row of “LoRaWAN Access 

 LoRaWAN Downlink” table; 

 

55 66 77 88: data to be written to the internal memory array of the converter. 

Содержание HD67D39-B2

Страница 1: ...r www adfweb com Product HD67D17 BACnet Slave www adfweb com Product HD67D18 Ethernet www adfweb com Product HD67D19 CAN www adfweb com Product HD67D20 CANopen www adfweb com Product HD67D21 DeviceNet...

Страница 2: ...ICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the prod...

Страница 3: ...vice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual LoRaWAN S7comm Client Document code MN67D39_ENG Revision 1 000 Page 4 of 30 EXAMPLE OF CONNECTION...

Страница 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual LoRaWAN S7comm Client Document code MN67D39_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1 Connection scheme for HD67D39 B2 xxxMHz...

Страница 6: ...nal information between LoRaWAN bus and S7comm bus Mountable on 35mm Rail DIN Wide power supply input range 12 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Co...

Страница 7: ...G Revision 1 000 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V...

Страница 8: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used f...

Страница 9: ...reen Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 LoRaWAN communication yellow Blinks when LoRaWAN data is received Blinks quickly Boot state Blinks very s...

Страница 10: ...r of stars topology in which gateways relay messages between end devices and a central network server The wireless communication takes advantage of the Long Range characteristics of the LoRa physical...

Страница 11: ...communication The Ethernet connection must be made using Connector2 of HD67D39 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to t...

Страница 12: ...Converter use the available software that runs with Windows called SW67D39 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Wind...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable LoRaWAN S7comm client Converter in order to configure another device in the same manne...

Страница 14: ...he language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Страница 15: ...RaWAN S7comm Client Document code MN67D39_ENG Revision 1 000 Page 15 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside th...

Страница 16: ...ation is defined In the field Transmission Type the type of LoRaWAN communication is defined In the field Max Payload Size the maximum dimension of the LoRaWAN messages is defined fixed in relation to...

Страница 17: ...r S7comm are In the fields IP ADDRESS the IP address for S7comm side of the converter is defined In the fields SUBNET Mask the SubNet Mask for S7comm side of the converter is defined In the fields GAT...

Страница 18: ...data to S7comm LORAWAN UPLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where ta...

Страница 19: ...AN DOWNLINK The means of the fields are If the field Enable is checked the LoRaWAN message is enabled In the field Start Byte the starting byte of the internal memory array where placing the data is d...

Страница 20: ...lds in the window S7comm Read are the following If the field Enable is checked the SNMP request is enabled In the field PLC Address the IP address of the PLC that contains the data to be read is defin...

Страница 21: ...e field Poll Time the frequency of the request is defined in ms In the field Position the starting byte of the internal memory array from which mapping the data read is defined In the field Start Bit...

Страница 22: ...a format of the variable to write is defined In the field Data Identifier the identifier of the variable to write is defined In the field DB Number the number of the DB of the PLC to write is defined...

Страница 23: ...of 30 The field Start Bit is used for the Bit data It is possible to select the bit of the selected Position from which taking the data If the field Swap is checked the bytes order is reversed If the...

Страница 24: ...net cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of...

Страница 25: ...rogram inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to program mo...

Страница 26: ...N Access section of SW67D39 Example 1 the converter is sending a LoRaWAN message related to row 4 of LoRaWAN Access LoRaWAN Uplink table of LoRaWAN Access section of SW67D39 with a Num Byte set of 4 T...

Страница 27: ...trial Electronic Devices ADFweb com S r l User Manual LoRaWAN S7comm Client Document code MN67D39_ENG Revision 1 000 Page 27 of 30 Figure 8 Mechanical dimensions scheme for HD67D39 B2 MECHANICAL DIMEN...

Страница 28: ...HD67D39 B 2 xxxMHz Frequency for LoRaWAN communication 868 868 MHz Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67D39 LoRaWAN S7comm Clien...

Страница 29: ...on systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recyc...

Страница 30: ...o the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to...

Отзывы: