background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com Srl – IT31010 – Mareno – Treviso                                                      INFO:  

www.adfweb.com

      Phone +39.0438.30.91.31            

 

User Manual   

OPC UA Server / SNMP Manager 

 

Document code: MN67B47_ENG     Revision 1.000    Page 1 of 24

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

User Manual 

Revision 1.000 
English 

 

OPC UA  Server / SNMP Manager - 
Converter

 

 

(Order Code: HD67B47-B2) 

 

for Website information:  

http://www.adfweb.com/?Product=HD67B47

    

 

for Price information: 

http://www.adfweb.com/?Price=HD67B47-B2

  

 
 

Benefits and Main Features: 

 

Triple electrical isolation 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C (-40°F/+185°F) 

For others OPC UA Server devices, see also the following links:  

 
OPC UA Server from/to …

 

www.adfweb.com?Product=HD67B26

  

(

Serial

www.adfweb.com?Product=HD67B27

  

(

Modbus Master

www.adfweb.com?Product=HD67B28

  

(

Modbus Slave

www.adfweb.com?Product=HD67B29

  

(

Modbus TCP Master

www.adfweb.com?Product=HD67B30

 

(

Modbus TCP Slave

www.adfweb.com?Product=HD67B31

 

(

Bacnet Master

www.adfweb.com?Product=HD67B32

  

(

Bacnet Slave

www.adfweb.com?Product=HD67B33

  

(

CAN

www.adfweb.com?Product=HD67B34

  

(

CANopen)

 

www.adfweb.com?Product=HD67B35

  

(

DeviceNet Master

www.adfweb.com?Product=HD67B36

  

(

DeviceNet Slave

www.adfweb.com?Product=HD67B37

  

(

DMX

www.adfweb.com?Product=HD67B38

  

(

EtherNet/IP Master

www.adfweb.com?Product=HD67B39

  

(

EtherNet/IP Slave

www.adfweb.com?Product=HD67B40

  

(

J1939

www.adfweb.com?Product=HD67B41

    

(

KNX

www.adfweb.com?Product=HD67B42

    

(

MQTT

www.adfweb.com?Product=HD67B43

    

(

NMEA0183

www.adfweb.com?Product=HD67B44

    

(

NMEA2000

www.adfweb.com?Product=HD67B47

  

(

PROFINET Master

www.adfweb.com?Product=HD67B46

    

(

PROFINET Slave

www.adfweb.com?Product=HD67B48

  

(

SNMP Agent

 
Do you have an your customer protocol? 

See the following links: 

www.adfweb.com?Product=HD67003

 

Do you need to choose a device? do you want help? 

Ask it to the following link: 

www.adfweb.com?Cmd=helpme

 

User Manual 

Содержание HD67B23

Страница 1: ...Modbus TCP Master www adfweb com Product HD67B30 Modbus TCP Slave www adfweb com Product HD67B31 Bacnet Master www adfweb com Product HD67B32 Bacnet Slave www adfweb com Product HD67B33 CAN www adfwe...

Страница 2: ...D TECHNICAL SUPPORT 24 RETURN POLICY 24 Pagina 2 di 24 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updat...

Страница 3: ...ocks etc QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation as...

Страница 4: ...ectronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 4 of 24 EXAMPLE O...

Страница 5: ...Fweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 5 of 24 Figure 1 Connection scheme f...

Страница 6: ...following characteristics Up to 1500 bytes in reading and 1500 bytes in writing Two directional information between SNMP and OPC UA Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC o...

Страница 7: ...r SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 7 of 24 POWER SUPPLY The devices can be powered between a wide range of tensions For more details see the two tables below VAC VDC Vmin Vma...

Страница 8: ...device has got two functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 in Off position factory setting is used for the normal working of the device The second with...

Страница 9: ...ly Boot state Blinks very slowly 0 5Hz update in progress 2 OPC UA comm yellow Flashing OPC UA request OFF OPC UA request Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 SNMP c...

Страница 10: ...T The Ethernet connection must be made using Connector3 of HD67B47 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norm...

Страница 11: ...r use the available software that runs with Windows called SW67B47 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last v...

Страница 12: ...ontains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a programmable OPC UA Server SNMP Manager Converter in order to confi...

Страница 13: ...here is the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section C...

Страница 14: ...9 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 14 of 24 In the section Software Settings it is possible to enable disable some keyboard s commands...

Страница 15: ...his feature is used for going out of the net In the field DNS the DNS address is defined This field is required if the server address is define by URL and not IP Address In the field Port the port use...

Страница 16: ...define the list of OPC UA variables to read write The means of the checkboxes inside the table are If the field Enable is checked the OPC UA variable is enabled In the field Type the data format of th...

Страница 17: ...fined selectable or editable manually In the field OID the OID to read write from to the SNMP Agent device is defined In the field Type the type of data to read write String or Int is defined In the f...

Страница 18: ...or the SNMP authentication is defined o In the field Auth Pass the password for the SNMP aithentication is defined o In the field Priv Pass the password for Privacy authentication is defined o In the...

Страница 19: ...rn ON the device Connect the Ethernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are...

Страница 20: ...C Try to restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that...

Страница 21: ...Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual OPC UA Server SNMP Manager Document code MN67B47_ENG Revision 1 000 Page 21 of 24 MECHANICAL DIMENSIONS Figure 8 Mech...

Страница 22: ...art number is formed by a valid combination of the following HD67B47 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67B47 OPC UA Server...

Страница 23: ...an countries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applic...

Страница 24: ...to exchange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information abou...

Отзывы: