Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

DMX / MQTT

 

 

Document code: MN67944_ENG     Revision 1.000   Page 1 of 31

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

 

User Manual 

Revision 1.000 
English 

 

DMX / MQTT - Converter 

 (Order Code:  HD67944-B2) 

 
 

For Website information:  

www.adfweb.com?Product=HD67944-B2

  

 

For Price information: 

www.adfweb.com?Price=HD67944-B2

 

 

 

Benefits and Main Features: 

 

Very easy to configure 

 

Power Supply 18…35V DC and 8…24 V AC 

 

Temperature range: -40°C/+85°C  (-40°F/+185°F) 

For others MQTT products, see also the following links: 

 

Converter MQTT to  

www.adfweb.com?Product=HD67930

      

(Ethernet) 

www.adfweb.com?Product=HD67931

       

(M-Bus) 

www.adfweb.com?Product=HD67932

      

(Serial) 

www.adfweb.com?Product=HD67933

      

(Modbus Master) 

www.adfweb.com?Product=HD67934

        

(Modbus Slave) 

www.adfweb.com?Product=HD67935

        

(Modbus TCP Master) 

www.adfweb.com?Product=HD67936

      

(Modbus TCP Slave) 

www.adfweb.com?Product=HD67937

        

(BACnet Master) 

www.adfweb.com?Product=HD67938

      

(BACnet Slave) 

www.adfweb.com?Product=HD67939

        

(CAN) 

www.adfweb.com?Product=HD67940

      

(CANopen) 

www.adfweb.com?Product=HD67941

        

(DALI) 

www.adfweb.com?Product=HD67942

        

(DeviceNet Master) 

www.adfweb.com?Product=HD67943

      

(DeviceNet Slave) 

www.adfweb.com?Product=HD67945

        

(EtherNet/IP) 

www.adfweb.com?Product=HD67946

        

(J1939) 

www.adfweb.com?Product=HD67947

        

(KNX) 

www.adfweb.com?Product=HD67948

        

(NMEA 0183) 

www.adfweb.com?Product=HD67949

        

(NMEA 2000) 

www.adfweb.com?Product=HD67950

        

(PROFIBUS Master) 

www.adfweb.com?Product=HD67951

        

(PROFIBUS Slave) 

www.adfweb.com?Product=HD67952

        

(PROFINET) 

www.adfweb.com?Product=HD67953

        

(SNMP Manager) 

www.adfweb.com?Product=HD67954

        

(SNMP Agent) 

 

 

Do you have an your customer protocol? 

www.adfweb.com?Product=HD67003

 

 

Do you need to choose a device? do you want help? 

www.adfweb.com?Cmd=helpme

 

 

User Manual   

 

Содержание HD67944-B2

Страница 1: ...67935 Modbus TCP Master www adfweb com Product HD67936 Modbus TCP Slave www adfweb com Product HD67937 BACnet Master www adfweb com Product HD67938 BACnet Slave www adfweb com Product HD67939 CAN www...

Страница 2: ...ND TECHNICAL SUPPORT 31 RETURN POLICY 31 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to...

Страница 3: ...an be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation of thi...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX MQTT Document code MN67944_ENG Revision 1 000 Page 4 of 31 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX MQTT Document code MN67944_ENG Revision 1 000 Page 5 of 31 CONNECTION SCHEME Figure 1 Connection scheme for HD67944 B2...

Страница 6: ...Electrical isolation between Ethernet and DMX Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compos...

Страница 7: ...G Revision 1 000 Page 7 of 31 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V...

Страница 8: ...osition of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used for upl...

Страница 9: ...links very slowly 0 5Hz update in progress 2 DMX communication yellow Blinks when DMX communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 MQTT status yello...

Страница 10: ...ike in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 82842 2x...

Страница 11: ...ation The Ethernet connection must be made using Connector2 of HD67944 B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568...

Страница 12: ...ter use the available software that runs with Windows called SW67944 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Windows XP...

Страница 13: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable DMX MQTT Converter in order to configure another device in the same manner it is neces...

Страница 14: ...guage of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to check...

Страница 15: ...nual DMX MQTT Document code MN67944_ENG Revision 1 000 Page 15 of 31 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the tabl...

Страница 16: ...By Pressing the Set Communication button from the main window for SW67944 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define the different...

Страница 17: ...p Alive seconds the delay with which the Keep Alive message is sent on MQTT is defined If the field Clean Session is checked the last MQTT messages are deleted by the Server and the Client in case of...

Страница 18: ...the MQTT messages are published is defined ETHERNET This section is used to define the general parameters of Ethernet The means of the fields are In the field Ip Address the IP address of the convert...

Страница 19: ...DNS the DNS address is defined This field is required if the server address is define by URL and not IP Address In the field Port the port used for MQTT communication is defined In the field SSID the...

Страница 20: ...address is define by URL and not IP Address In the field Port the port used for MQTT communication is defined In the field SSID the name of the Wi Fi network to connect is defined In the field Passwor...

Страница 21: ...Figure 3h Set Communication NTP window NTP NETWORK TIME PROTOCOL This section is used to define the parameters of NTP protocol The means of the fields are In the field Server URL the URL or the IP Ad...

Страница 22: ...PUBLISH IF DMX IN IS SET The means of the fields are In the field Topic the MQTT topic is defined If the field Retained is defined the retained flag is enabled The MQTT server will hold the last topi...

Страница 23: ...ed In the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the field Dimension the dimension in byte of the data is defined In the field Position the sta...

Страница 24: ...ge 24 of 31 DMX DEFAULT VALUE By pressing the DMX Default Value button from the main window for SW67944 Fig 2 the DMX Default Value window appears Fig 5 In this section it is possible to define the de...

Страница 25: ...le Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of Dip Sw...

Страница 26: ...tart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have th...

Страница 27: ...essary in order to define the structure of the payload of the MQTT message and the info contained It is possible to have a simple text format or a JSON format The definition of the template can be don...

Страница 28: ...Industrial Electronic Devices ADFweb com S r l User Manual DMX MQTT Document code MN67944_ENG Revision 1 000 Page 28 of 31 Figure 8 Mechanical dimensions scheme for HD67944 B2 MECHANICAL DIMENSIONS...

Страница 29: ...a valid combination of the following HD67944 B 2 Connectors Type 2 Fixed Screw Terminal Enclosure Type B Modulbox 4M 35mm DIN Rail mounting Device Family HD67944 DMX MQTT Converter Order Code HD67944...

Страница 30: ...tems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycling o...

Страница 31: ...ollowing Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to the add...

Отзывы: