background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l.           

User Manual   

Modbus Master / MQTT

 

 

Document code: MN67933_ENG     Revision 1.101   Page 14 of 45

 

 

 

LEDS: 

 
The device has got five LEDs that are used to give information of the functioning status. 
The various meanings of the LEDs are described in the table below. 

 

LED 

Normal Mode 

Boot Mode 

1: Device State (green) 

Blinks slowly (~1Hz) 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

2: MQTT communication 
(yellow) 

Blinks when MQTT communication is running 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

3: Modbus communication 
(yellow) 

Blinks when Modbus communication is running 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

4:Modbus error (yellow) 

Turns ON when an error occurs 

Blinks quickly:

 Boot state 

Blinks very slowly (~0.5Hz):

 update in progress 

5: Ethernet Link (green) 

ON:

 Ethernet cable connected 

OFF:

 Ethernet cable disconnected 

ON:

 Ethernet cable connected 

OFF:

 Ethernet cable disconnected 

 

Содержание HD67933 B2 Series

Страница 1: ...s Slave www adfweb com Product HD67935 Modbus TCP Master www adfweb com Product HD67936 Modbus TCP Slave www adfweb com Product HD67937 BACnet Master www adfweb com Product HD67938 BACnet Slave www ad...

Страница 2: ...REGULATIONS AND STANDARDS 44 WARRANTIES AND TECHNICAL SUPPORT 45 RETURN POLICY 45 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the...

Страница 3: ...ice can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operation o...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 4 of 45 EXAMPLE OF CONNECTION...

Страница 5: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 5 of 45 CONNECTION SCHEME Figure 1a Connection scheme for HD67933 2 B2...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 6 of 45 Figure 1b Connection scheme for HD67933 4 B2...

Страница 7: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 7 of 45 Figure 1c Connection scheme for HD67933 2 G43 B2...

Страница 8: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 8 of 45 Figure 1d Connection scheme for HD67933 4 G43 B2...

Страница 9: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 9 of 45 Figure 1e Connection scheme for HD67933 2 GPRS B2...

Страница 10: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 10 of 45 Figure 1e Connection scheme for HD67933 4 GPRS B2...

Страница 11: ...isolation between MQTT and Modbus Mountable on 35mm Rail DIN Wide power supply input range 18 35V DC and 8 24V AC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67933...

Страница 12: ...01 Page 12 of 45 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption at 24V DC Device Con...

Страница 13: ...the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is used fo...

Страница 14: ...ks very slowly 0 5Hz update in progress 2 MQTT communication yellow Blinks when MQTT communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 Modbus communicati...

Страница 15: ...code MN67933_ENG Revision 1 101 Page 15 of 45 RS232 The connection from RS232 socket to a serial port example one from a personal computer must be made with a NULL MODEM cable a serial cable where th...

Страница 16: ...p 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield Belden p n 828...

Страница 17: ...d not exceed 100m The cable has to conform to the T568 norms relative to connections in cat 5 up to 100 Mbps To connect the device to an Hub Switch is recommended the use of a straight cable to connec...

Страница 18: ...onverter use the available software that runs with Windows called SW67933 It is downloadable on the site www adfweb com and its operation is described in this document The software works with MS Windo...

Страница 19: ...iguration A device s configuration can also be imported or exported To clone the configurations of a Programmable Modbus Master MQTT Converter in order to configure another device in the same manner i...

Страница 20: ...e language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible to...

Страница 21: ...Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 21 of 45 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation inside the...

Страница 22: ...n button from the main window for SW67933 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define the different parameters of the converter Sele...

Страница 23: ...eld Device Name Hostname the Hostname to assign to the converter is defined If the field Obtain an IP Address Automatically DHCP for Cable Connection is checked DHCP for LAN connection is enabled If t...

Страница 24: ...are In the field Serial the serial port to use is defined RS232 or RS485 In the field Baudrate the baudrate for the serial line is defined In the field Parity the parity of the serial line is defined...

Страница 25: ...d the converter will publish the Will topic at the connection to the Server With this feature in case of incorrect disconnection the Server will publish this topic to all the MQTT Clients that subscri...

Страница 26: ...d This feature is used for going out of the net TLS TRANSPORT LAYER SECURITY This section is used to define the parameters of TLS protocol The means of the fields are If the field Enable TLS is checke...

Страница 27: ...n the field Subnet Mask the SubNet Mask of the converter is defined In the field GATEWAY the default gateway of the net is defined This feature can be enabled or disabled pressing the Check Box field...

Страница 28: ...e of the converter is defined In the field Subnet Mask MQTT the SubNet Mask for MQTT side of the converter is defined In the field GATEWAY MQTT the default gateway of the MQTT net is defined This feat...

Страница 29: ...ll subscribes for writing the data to Modbus The means of the fields are In the field Topic the MQTT topic is defined If the field Retained is defined the retained flag is enabled The MQTT server will...

Страница 30: ...pic the MQTT topic is defined If the field Retained is defined the retained flag is enabled The MQTT server will hold the last topic published In the field QoS the QoS level is defined In the field Da...

Страница 31: ...l Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 31 of 45 If the field On Timer is checked the converter publishes the topic cyclically with the delay defined in the field Time ms In...

Страница 32: ...bled The MQTT server will hold the last topic published In the field QoS the QoS level is defined In the field Data Type the type of data to use is defined In the field Dimension the dimension in byte...

Страница 33: ...the following o Coil Status o Input Status o Holding Register o Input Register In the field Address the starting address of the register to be read is defined In the field NPoint the number of consecu...

Страница 34: ...pe of the register to read is defined It is possible to choose between the following o Coil Status o Input Status o Holding Register o Input Register In the field Address the starting address of the r...

Страница 35: ...o make the request is defined If the field On Change is checked the converter sends the writing request when the data from MQTT side change value If the field On CMD is checked the converter sends the...

Страница 36: ...t cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip1 of D...

Страница 37: ...o restart the PC Check the LAN settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you ha...

Страница 38: ...This template is valid for the Modbus requests in reading The definition of the template can be done using Key words used to link a specific information of the Modbus requests The key words used and...

Страница 39: ...300 NPoint 1 We define a template string in this way Modbus ID SOURCE Function Code FC Modbus register ADDRESS Num of Registers NPOINT Data VALUE The output of MQTT will be Row 1 Modbus ID 1 Function...

Страница 40: ...se the Modbus request It is necessary to use a JSON format described below slave id SOURCE fc FC address ADDRESS npoint NPOINT value VALUE topic index INDEX Where SOURCE ID of the Modbus slave FC Func...

Страница 41: ...com S r l User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 41 of 45 Figure 10a Mechanical dimensions scheme for HD67933 X B2 Figure 10b Mechanical dimensions scheme for HD6...

Страница 42: ...RS Serial port 2 RS232 4 RS485 Device Family HD67933 Modbus Master MQTT Converter Order Code HD67933 2 B2 Modbus Master MQTT Converter Modbus port RS232 Order Code HD67933 4 B2 Modbus Master MQTT Conv...

Страница 43: ...User Manual Modbus Master MQTT Document code MN67933_ENG Revision 1 101 Page 43 of 45 ACCESSORIES Order Code AC34011 35mm Rail DIN Power Supply 220 240V AC 50 60Hz 12 V DC Order Code AC34012 35mm Rai...

Страница 44: ...n systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the recycl...

Страница 45: ...the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product to th...

Отзывы: