CHARACTERISTICS: 
 

The HD67909-A1 are Modbus TCP Slave / HART Master - Converters. 

 

It allows for the following characteristics: 

 

Triple isolation between Ethernet - Power Supply, Ethernet - HART, HART - Power Supply; 

 

Two-directional information between Ethernet bus and HART bus; 

 

Mountable on 35mm Rail DIN; 

 

Wide power supply input range: 8…24V AC or 12…35V DC; 

 

Wide temperature range:  -40°C / 85°C [-40°F / +185°F]. 

 

 

CONFIGURATION: 
 

You need Compositor SW67909 software on your PC in order to perform the following: 

 

Define the parameters of Modbus TCP line; 

 

Define the parameters of HART line; 

 

Define HART variables in read/write; 

 

Define HART rules for gateway functions; 

 

Scan and configure HART devices by integrated webserver; 

 

Update the device. 

Содержание HD67909-A1

Страница 1: ...er HART Master to www adfweb com Product HD67900 Serial www adfweb com Product HD67901 BACnet Slave www adfweb com Product HD67902 CAN www adfweb com Product HD67903 CANopen www adfweb com Product HD6...

Страница 2: ...URN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to the product you own To obta...

Страница 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual Modbus TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 4 of 30 EXAMPLES OF CONNECTION...

Страница 5: ...ndustrial Electronic Devices ADFweb com S r l User Manual Modbus TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67909 A...

Страница 6: ...ART Power Supply Two directional information between Ethernet bus and HART bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185...

Страница 7: ...N67909_ENG Revision 1 001 Page 7 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumptio...

Страница 8: ...st with Dip2 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip2 of Dip Switch A at ON position is used for uploading the Project and or Firmware For the...

Страница 9: ...communication green It blinks when HART communication is running Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 2 Ethernet link green ON Ethernet cable connected OFF Ethernet c...

Страница 10: ...signals at a low level on top of the 4 20mA This enables two way field communication to take place and makes it possible for additional information beyond just the normal process variable to be commun...

Страница 11: ...unication must be made using Connector4 of the HD67909 A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the T568 norms relative t...

Страница 12: ...at runs with Windows called SW67909 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Страница 13: ...configuration A device s configuration can also be imported or exported To clone the configurations of a programmable Modbus TCP Slave HART Master in order to configure another device in the same man...

Страница 14: ...e the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possible...

Страница 15: ...s TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 15 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Страница 16: ...case of missing response from HART device is defined The means of the fields for the Modbus Slave section are In the field IP Address the IP address of the converter is defined In the field SubNet Mas...

Страница 17: ...bles to read write with the Modbus Master The means of the fields are If the field Enable is checked the HART variable is enabled In the field Device Address the address of HART device is defined In t...

Страница 18: ...g the HART data is defined In the field Swap the bytes order is reversed In the field Conv Int the data from HART device is converted in Integer format In the field Operations a post operation on the...

Страница 19: ...hernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip2...

Страница 20: ...he program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progra...

Страница 21: ...Variables section It has the following characteristics Possibility to scan HART network Automatic decode of HART messages Easy connection directly through the Ethernet port of the converter In order t...

Страница 22: ...ess configured in the converter Start the Scan by clicking on Start Scan button The window will appear like below When the Scan is complete the software will show the results You can import the data b...

Страница 23: ...like Internet Explorer Google Chrome Mozilla Firefox by editing the IP Address of the converter in the address bar of the browser WELCOME As soon as the connection to the Webserver interface of the D...

Страница 24: ...Slave HART Master Document code MN67909_ENG Revision 1 001 Page 24 of 30 When one of the buttons of the Welcome page are pressed it is necessary to do the login using the Admin and Password defined in...

Страница 25: ...Scan button is pressed the HART Scan window appears Fig 10 It has the following fields NUMBER OF DEVICES TO SEARCH FOR Maximum 16 field number of Hart devices connected Scan Start button it is possibl...

Страница 26: ...a discovered HART node from HART Scan section is selected the HART Control window appears Fig 11 It has the following fields UNIQUE ID button it is possible to insert the unique ID of the HART device...

Страница 27: ...l Electronic Devices ADFweb com S r l User Manual Modbus TCP Slave HART Master Document code MN67909_ENG Revision 1 001 Page 27 of 30 MECHANICAL DIMENSIONS Figure 12 Mechanical dimensions scheme for H...

Страница 28: ...on of the following HD67909 xx Connectors Type 1 Removable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting Device Family HD67909 Modbus TCP Slave HART Master Converter Order Code HD67909...

Страница 29: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Страница 30: ...e do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: