CONNECTION SCHEME: 

 

 

Figure 1: Connection scheme for HD67810-KNX-B2

 

 

Содержание HD67810-KNX-B2

Страница 1: ...m Product HD67802 BACnet Slave www adfweb com Product HD67803 CAN www adfweb com Product HD67804 CANopen www adfweb com Product HD67807 EtherNet IP www adfweb com Product HD67808 DeviceNet Master www...

Страница 2: ...D TECHNICAL SUPPORT 26 RETURN POLICY 26 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following document is Updated Related to t...

Страница 3: ...QUALIFIED PERSONNEL The device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly c...

Страница 4: ...trial Electronic Devices ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 KNX Document code MN67810_ENG Revision 1 001 Pagina 4 di 26 EXAMPLE OF CONNE...

Страница 5: ...ces ADFweb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 KNX Document code MN67810_ENG Revision 1 001 Pagina 5 di 26 CONNECTION SCHEME Figure 1 Connection...

Страница 6: ...ctional information between KNX bus and J1939 bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Comp...

Страница 7: ...KNX Document code MN67810_ENG Revision 1 001 Pagina 7 di 26 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 2...

Страница 8: ...functions mode depending of the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch...

Страница 9: ...Blinks very slowly 0 5Hz update in progress 2 J1939 communication yellow Blinks when J1939 frame is received Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 KNX communication y...

Страница 10: ...n 1 001 Pagina 10 di 26 J1939 For terminate the J1939 line with a 120 resistor it is necessary that the Dip1 of Dip Switch C is at ON position Cable characteristics DC parameter Impedance 70 Ohm m AC...

Страница 11: ...ing to control dampers to the security to the heating monitoring to the conditioning to the hydric control and alarms to energy management and so on Characteristics Description TP1 256 Medium Shielded...

Страница 12: ...e used for programming the device The Ethernet connection must be made using Connector2 of HD67810 KNX B2 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The c...

Страница 13: ...he available software that runs with Windows called SW67810 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version...

Страница 14: ...contains the entire device s configuration A device s configuration can also be imported or exported To clone the configurations of a Programmable J1939 KNX Converter in order to configure another dev...

Страница 15: ...the possibility to change the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connectio...

Страница 16: ...side of the converter is defined The means of the fields for the J1939 section are In the field Baudrate the baudrate for the J1939 line is defined In the field TimeOut Data s a time is defined When t...

Страница 17: ...ted by In the field APCI the APCI of the KNX message is defined You can choose between the following o Read it is used to send a reading request to a KNX device o Write it is used to send a writing re...

Страница 18: ...he information In the field Bit Mode insert the start bit of the first byte of the field Position where start to insert the data read In the field Length the dimension of the KNX message is defined In...

Страница 19: ...d in the J1939 protocol the PGN is an identifier In the field Source Address the source address of the device that send the frame is defined If the field Transport Protocol is checked the frame uses T...

Страница 20: ...the field Data Page the data page of the J1939 message is defined The value can be 0 or 1 usually it is 0 In the field PGN the PGN of the J1939 message to be written from KNX is defined in J1939 prot...

Страница 21: ...n Device Found must appear Press the Next button Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device...

Страница 22: ...g Try with another PC Try to restart the PC Check the LAN settings Check the Wi Fi settings If you are using the program inside a Virtual Machine try to use in the main Operating System If you are usi...

Страница 23: ...eb com Srl IT31010 Mareno Treviso INFO www adfweb com Phone 39 0438 30 91 31 User Manual J1939 KNX Document code MN67810_ENG Revision 1 001 Pagina 23 di 26 MECHANICAL DIMENSIONS Figure 9 Mechanical di...

Страница 24: ...D67810 KNX B 2 Connectors Type 2 Fixed 5mm Screw Terminal Enclosure Type B 4M 35mm DIN Rail mounting Device Family HD67810 KNX J1939 KNX Converter Order Code HD67810 KNX B2 J1939 KNX Converter ACCESSO...

Страница 25: ...ries with separate collection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable col...

Страница 26: ...hange or repair it please do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the p...

Отзывы: