background image

   

Industrial

 

Electronic Devices 

 

 

 ADFweb.com S.r.l. 

 

User Manual   

IEC 61850 Server / BACnet Slave

 

 

Document code: MN67738_ENG     Revision 1.000   Page 15 of 30

 

 

 

SOFTWARE OPTIONS: 

 

By  pressing  the  “

Settings

”  (

)  button    there  is  the  possibility  to  change  the  language  of  the  software  and  check  the  updatings  for  the 

compositor. 
 
In  the  section  “Language”  it  is  possible  to  change  the  language  of  the 
software. 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
In  the  section  “Connection  Options”,  it is  possible  to  check  if  there  are  some 
updatings of the software compositor in ADFweb.com website. 
Checking  the  option  “

Check  Software  Update  at  Start  of  Program

”,  the 

SW67738 checks automatically if there are updatings when it is launched. 

Содержание HD67737-A1

Страница 1: ...us TCP Master www adfweb com Product HD67736 Modbus TCP Slave www adfweb com Product HD67737 BACnet Master www adfweb com Product HD67739 CAN www adfweb com Product HD67740 CANopen www adfweb com Prod...

Страница 2: ...TANDARDS 29 WARRANTIES AND TECHNICAL SUPPORT 30 RETURN POLICY 30 UPDATED DOCUMENTATION Dear customer we thank you for your attention and we remind you that you need to check that the following documen...

Страница 3: ...e device can be used only by qualified personnel strictly in accordance with the specifications Qualified personnel are persons who are familiar with the installation assembly commissioning and operat...

Страница 4: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server BACnet Slave Document code MN67738_ENG Revision 1 000 Page 4 of 30 EXAMPLES OF CONNECTION...

Страница 5: ...ustrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server BACnet Slave Document code MN67738_ENG Revision 1 000 Page 5 of 30 CONNECTION SCHEME Figure 1a Connection scheme for HD67738 IP...

Страница 6: ...Industrial Electronic Devices ADFweb com S r l User Manual IEC 61850 Server BACnet Slave Document code MN67738_ENG Revision 1 000 Page 6 of 30 Figure 1b Connection scheme for HD67738 MSTP A1...

Страница 7: ...BACnet bus Mountable on 35mm Rail DIN Wide power supply input range 8 24V AC or 12 35V DC Wide temperature range 40 C 85 C 40 F 185 F CONFIGURATION You need Compositor SW67738 software on your PC in...

Страница 8: ...7738_ENG Revision 1 000 Page 8 of 30 POWER SUPPLY The devices can be powered at 8 24V AC and 12 35V DC For more details see the two tables below VAC VDC Vmin Vmax Vmin Vmax 8V 24V 12V 35V Consumption...

Страница 9: ...on the position of the Dip1 of Dip Switch A The first with Dip1 of Dip Switch A at OFF position is used for the normal working of the device The second with Dip1 of Dip Switch A at ON position is use...

Страница 10: ...green Blinks slowly 1Hz Blinks quickly Boot state Blinks very slowly 0 5Hz update in progress 3 BACnet communication green It blinks when a BACnet request is received Blinks quickly Boot state Blinks...

Страница 11: ...nverters must be made using Connector3 and or Connector4 of the HD67738 XXX A1 with at least a Category 5E cable The maximum length of the cable should not exceed 100m The cable has to conform to the...

Страница 12: ...ry to put ON dip 1 like in figure The maximum length of the cable should be 1200m 4000 feet Here some codes of cables Belden p n 8132 2x 28AWG stranded twisted pairs conductor foil shield braid shield...

Страница 13: ...hat runs with Windows called SW67738 It is downloadable on the site www adfweb com and its operation is described in this document This manual is referenced to the last version of the software present...

Страница 14: ...iguration A device s configuration can also be imported or exported To clone the configurations of a programmable IEC 61850 Server BACnet Slave Converter in order to configure another device in the sa...

Страница 15: ...ge the language of the software and check the updatings for the compositor In the section Language it is possible to change the language of the software In the section Connection Options it is possibl...

Страница 16: ...850 Server BACnet Slave Document code MN67738_ENG Revision 1 000 Page 16 of 30 In the section Software Settings it is possible to enable disable some keyboard s commands for an easier navigation insid...

Страница 17: ...ION By Pressing the Set Communication button from the main window for SW67738 Fig 2 the window Set Communication appears Fig 3 The window is divided in different sections in order to define the differ...

Страница 18: ...IEC 61850 variables is defined TLS TRANSPORT LAYER SECURITY SERVER This section is used to define the main parameters of TLS protocol The means of the fields are If the field Enable TLS is checked the...

Страница 19: ...feature can be enabled or disabled pressing the Check Box field This feature is used for going out of the net In the field Port the port used for BACnet communication is defined The default port used...

Страница 20: ...imum number of information frames the node may send before it must pass the token In the field Device Istance it is possible to assign a number to the BACnet node used for the Device Istance In the fi...

Страница 21: ...format of the IEC 61850 variable is defined In the field Length the dimension of the IEC 61850 variable is defined If the field Read Only is checked the IEC 61850 variable is just in reading Otherwis...

Страница 22: ...contains the BACnet objects writeable by a BACnet Master The meaning of the fields in the window are the follows In the field Data Type is possible to select the BACnet object data type In the field E...

Страница 23: ...ble to insert directly the Unit using its unique number by compiling the Selected BACnet Engineering Unit field or by selecting with the fields Select the Type and Select unit the Type Unit desired If...

Страница 24: ...2 the Definition the list of Known Certificates window appears Fig 7 The data of the columns have the following meanings If the field Enable is checked the TLS certificate is allowed In the field Cert...

Страница 25: ...thernet cable Insert the IP 192 168 2 205 Select which operations you want to do Press the Execute update firmware button to start the upload When all the operations are OK turn OFF the Device Put Dip...

Страница 26: ...he program inside a Virtual Machine try to use in the main Operating System If you are using Windows Seven Vista 8 or 10 make sure that you have the administrator privileges In case you have to progra...

Страница 27: ...lectronic Devices ADFweb com S r l User Manual IEC 61850 Server BACnet Slave Document code MN67738_ENG Revision 1 000 Page 27 of 30 MECHANICAL DIMENSIONS Figure 10 Mechanical dimensions scheme for HD6...

Страница 28: ...movable 5mm Screw Terminal Enclosure Type A 1M 35mm DIN Rail mounting BACnet port IP BACnet IP MSTP BACnet MS TP Device Family HD67738 IEC 61850 Server BACnet Slave Converter Order Code HD67738 IP A1...

Страница 29: ...ection systems This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish Instead it should be taken to an applicable collection point for the r...

Страница 30: ...se do the following Obtain a Product Return Number PRN from our internet support at www adfweb com Together with the request you need to provide detailed information about the problem Send the product...

Отзывы: